• Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
  • Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
  • Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
  • Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
  • Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
  • Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global
Favorit

Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global

Aplikasi: Industri
Kecepatan Anda: Kecepatan konstan
Jumlah stator: Tiga Fase
Fungsi: Mengemudi
Perlindungan casing: Tipe Perlindungan
Jumlah kutub: 4

Hubungi Pemasok

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik & Perusahaan Dagang
  • Ringkasan
  • Recommendation
  • Product Description
  • Company Profile
  • FAQ
Ringkasan

Informasi dasar.

Mode Start
Penyalaan x-δ
Sertifikasi
ISO9001, CCC, CE
Merek
Liyuan
rumah
besi cor
sampul
besi cor
kotak terminal
ppo
kipas
pp
penutup kipas
A3
poros
C45
Paket Transportasi
Carton or Plywood
Merek Dagang
LIYUAN
Asal
Fuan
Kode HS
8501520000
Kapasitas Produksi
50000 Pieces/Year

Deskripsi Produk

Y2 10HP 15HP 20HP 25HP 30HP 40HP 50HP 60HP Three 3 Phase AC induction electric Motor
Recommendation

 

Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Product Description
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global SourcesElectrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources

 

Model kw HP Current Speed Eff Power Factor Tst/Tn Ist/In Tmax/Tn
Y2-90L-4 1.5 2 3.65A 1400 rpm 79% 0.79 2.3 6.5 2.3
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources
Company Profile
Electrical Motor (1/4HP-10HP) Yy Ml Mc My Yc Ycl Yl Capacitor Start Capacitor Run Single Phase AC Asynchronous Induction Electric Wholesale Global Sources

 

FAQ
  1. There are other factors that cause motor vibration and noise!
    Axial vibration and noise of end caps
    The axial vibration of the end cover is one of the sources of mechanical noise, which is mainly excited by the bearing vibration, which is more important in small motors. The smaller the axial dynamic stiffness of the end cover, the easier it is to excite larger vibration speed and noise.

     
    Vibration and noise of the brush unit

    The vibration and noise of the brush device are caused by the poor surface condition of the commutator, the large gap between the brush and the brush holder, the small brush pressure or the improper pressure application which makes the brush skew, and the brush holder, brush holder and brush rod. It is caused by structural and technological reasons such as insufficient stiffness.



    When the DC motor is running, the sliding contact condition of the brush and the commutator, as well as the cuprous oxide film formed on the surface of the commutator and a layer of graphite film and dust particles covered on it, not only affect the commutation performance of the motor, but also affect the commutation performance of the motor. to vibration and noise.

     
    Practice has proved that due to the low temperature of the sliding contact surface at no load, the above-mentioned film is not easy to form, and the dry friction between the brush and the commutator increases the noise. For example, when the no-load operation cycle of the rolling DC motor accounts for more than 50% of the total time, the noise under no-load conditions is 6~10dB higher than that under load. This vibration is different from the vibration of the commutator surface due to mechanical reasons, which can be detected when the motor is running at low speed (vibration is felt when the brush is touched by hand). The frequency spectrum of brush vibration noise generated by sliding contact is generally in the range of 1000~-8000Hz, and it does not change much when the motor speed changes, which is one of the characteristics that distinguish it from mechanical reasons.

     
    The brush vibration noise produced by the sliding contact is also related to the brush polarity. For example, the positive brush of a DC generator has less vibration than the negative brush; because the positive brush can separate graphite and carbon crystals, absorb moisture on the surface of the commutator to form a lubricating film, and the negative brush removes it. The formation of the sliding contact film is also related to the grade of the brush. The selection of the grade is first to ensure good commutation performance, but at the same time, the vibration and noise of the brush should also be considered.

     
    In addition to mechanical noise, aerodynamic noise is also a major problem in motor noise control. Especially for high-speed motors, this problem is relatively concentrated. In the tweet after bearing, Ms. participated in the meeting and chose some content to share with you.

Kirim permintaan informasi Anda langsung ke penyedia ini

*Dari:
*Untuk:
*Pesan:

Masukkan antara 20 dan 4000 karakter.

Ini bukan yang Anda cari? Posting Permintaan Sourcing SEKARANG

Temukan Produk Serupa Berdasarkan Kategori

Beranda Pemasok Produk Motor Motor tiga Fase Motor Elektrik (1/4HP-10HP) yy ml Mc My Ycl Yl Yl Kapasitor Start Capacititor menjalankan Single Phase AC Asinkron Induksi Electric Sumber Grosir Global

Anda Mungkin Juga Menyukai

Hubungi Pemasok

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik & Perusahaan Dagang
Jumlah Karyawan
39
Tahun Pendirian
2011-07-05