Heat Temperature: | 50-70°C |
---|---|
Work Environment: | Common Heat Pump |
Heat Source: | Water-source |
Application: | Villa Family |
Certification: | CE, ISO9001, CCC |
nama produk: | pompa panas sumber air/tanah untuk pendinginan & pemanasan |
Pemasok dengan izin usaha terverifikasi
pendinginan & pemanasan pompa panas sumber air (ground) | ||||||||||||||
Odle | CRS-4I | CRS-8I | CRS-12II | CRS-20II | CRS-40II | CRS-70II | CRS-80II | CRS-120II | CRS-165II | CRS-200II | CRS-240II | CRS-300II | ||
Kapasitas pendinginan | KW | 4 | 8 | 12 | 20 | 40 | 60 | 80 | 120 | 165 | 200 | 240 | 300 | |
Kapasitas pemanasan | KW | 4.3 | 8.6 | 13 | 22 | 45 | 69 | 91 | 131 | 176 | 213 | 260 | 315 | |
Daya masukan pendinginan | KW | 0.8 | 1.6 | 2.5 | 4.1 | 8.3 | 12.7 | 16.6 | 25.3 | 32.3 | 39.2 | 47 | 58.8 | |
daya input pemanasan | KW | 0.95 | 1.9 | 2.8 | 4.7 | 10.4 | 14.6 | 20.6 | 27.2 | 39.1 | 47.3 | 57.7 | 70 | |
Arus input pendinginan | A | 4.3 | 8.4 | 4.5 | 7.5 | 15 | 22.7 | 29.5 | 45.5 | 58 | 71 | 85 | 106 | |
Arus input pemanasan | A | 5.1 | 10.1 | 5.2 | 8.5 | 18.6 | 27 | 37 | 50.3 | 71 | 86 | 106 | 127 | |
Saluran kerja bawah tanah | Kapasitas pendinginan | KW | 3.9 | 7.7 | 11.5 | 19.5 | 38.4 | 57.6 | 76.9 | 115.3 | 158.6 | 192.3 | 230.7 | 288.4 |
Kapasitas pemanasan | KW | 4.2 | 8.2 | 12.5 | 21.2 | 43.2 | 66.3 | 85.1 | 125.9 | 169.2 | 204.8 | 250 | 302.8 | |
Daya masukan pendinginan | KW | 0.81 | 1.6 | 2.4 | 4.1 | 8.2 | 12.4 | 16.7 | 24.9 | 32.3 | 39.2 | 47 | 58 | |
Daya input pemanasan | KW | 0.93 | 1.8 | 2.7 | 4.8 | 10 | 15.4 | 20.3 | 29.2 | 41.2 | 49.9 | 60.9 | 73.8 | |
Arus input pendinginan | A | 4.2 | 8.5 | 4.5 | 7.5 | 15 | 23.5 | 31.5 | 46 | 60.2 | 72.9 | 86 | 105 | |
Arus input pemanasan | A | 4.8 | 9.8 | 5.3 | 9.1 | 18 | 29.1 | 37.5 | 55.3 | 76.6 | 92.8 | 113.2 | 137 | |
Kondisi kerja nominal tipe lingkaran bawah tanah | Kapasitas pendinginan | KW | 3.8 | 7.6 | 11.4 | 19.1 | 38 | 57 | 76.2 | 114.1 | 157 | 190.3 | 228.4 | 285.5 |
Kapasitas pemanasan | KW | 4.1 | 8.1 | 12.3 | 20.9 | 42 | 65 | 80.1 | 124.6 | 167.5 | 202.3 | 247.5 | 299.8 | |
Daya masukan pendinginan | KW | 0.8 | 1.6 | 2.4 | 4.2 | 8.4 | 12.7 | 16.9 | 25.3 | 32.9 | 39.8 | 47.8 | 59.8 | |
Daya input pemanasan | KW | 1.1 | 2.1 | 3.1 | 5.1 | 10.5 | 16.2 | 20 | 31.1 | 41.8 | 50.5 | 61.8 | 74 | |
Arus input pendinginan | A | 4.2 | 8.4 | 4.7 | 7.9 | 15.6 | 23.6 | 31.9 | 47 | 61.1 | 74 | 88 | 111 | |
Arus input pemanasan | A | 5.7 | 11.1 | 5.8 | 9.6 | 18 | 30.1 | 37.8 | 57.8 | 77.7 | 93 | 114 | 139.3 | |
Pengaturan kerja air di dalam lingkaran | Kapasitas pendinginan | KW | 3.6 | 7.2 | 10.9 | 18.1 | 36.2 | 54.3 | 72.4 | 108.7 | 149.5 | 181.3 | 217.5 | 271.9 |
Kapasitas pemanasan | KW | 4.7 | 10.3 | 15.6 | 26.4 | 54.6 | 84.5 | 104 | 161.9 | 218 | 266 | 330 | 390 | |
Daya masukan pendinginan | KW | 0.95 | 1.9 | 2.9 | 4.8 | 9.5 | 14.2 | 19.1 | 28.6 | 36.4 | 44.2 | 53 | 66.3 | |
Daya input pemanasan | KW | 1.04 | 2.3 | 3.4 | 6 | 12.1 | 18.7 | 23.1 | 35.9 | 43.6 | 53.2 | 66 | 78 | |
Arus input pendinginan | A | 5.1 | 10.3 | 5.6 | 9.3 | 17.6 | 26.4 | 36 | 53.1 | 67.7 | 82 | 98 | 123.3 | |
Arus input pemanasan | A | 5.5 | 12.3 | 6.7 | 11.4 | 22.5 | 34.7 | 43 | 66.7 | 81 | 98 | 122.7 | 145 | |
daya | 220V/50Hz | 380V/50Hz | ||||||||||||
Kompresor | tipe | Rotor | Gulir | Kompresor Pendinginan Pendingin ruangan Ganda | ||||||||||
TIDAK. | SATUAN | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | 1 | 1 | |
Pengaturan energi | % | 0, 100 | 0, 100 | 0, 100 | 0, 100 | 0, 100 | 0, 50, 100 | 0, 50, 100 | 0, 50, 100 | 0, 25, 50, 75, 100 | ||||
Heat exchanger sisi sumber pemanasan | Tipe | Heat exchanger tipe pelat | Selubung tipe horizontal & heat exchanger tabung | |||||||||||
Air bawah tanah membuat air pendingin mengalir | m 3 /h | 0.36 | 0.7 | 1 | 1.7 | 3.4 | 5.2 | 6.7 | 10.8 | 14.2 | 16 | 20 | 24 | |
Air bawah tanah membuat air pemanas mengalir | m 3 /h | 0.42 | 0.83 | 1.3 | 2.1 | 4.2 | 6.2 | 8.3 | 12.4 | 17 | 21 | 25 | 31 | |
Aliran air dingin kondisi kerja nominal tipe lingkaran bawah tanah | m 3 /h | 0.7 | 1.4 | 2.2 | 3.6 | 7.2 | 11.2 | 13.7 | 21.4 | 28.8 | 35 | 42 | 52 | |
Aliran air panas pada jenis lingkaran bawah tanah dengan kondisi kerja yang nominal | m 3 /h | 0.65 | 1.3 | 1.96 | 3.3 | 6.5 | 9.8 | 13.1 | 19.6 | 27 | 33 | 39.5 | 49 | |
Antarmuka tabung air | mm | DN20 | DN20 | DN20 | DN25 | DN40 | DN50 | DN80 | DN100 | |||||
Heat exchanger sisi pengguna | Tipe | Heat exchanger tipe pelat | Selubung tipe horizontal & heat exchanger tabung | |||||||||||
aliran air pendingin | m3/j | 0.7 | 1.4 | 2.1 | 3.4 | 6.8 | 10.3 | 13.7 | 20 | 28.3 | 34.4 | 41.3 | 52 | |
Aliran air panas | m3/j | 0.74 | 1.5 | 2.2 | 3.8 | 7.7 | 11.8 | 15.6 | 22.5 | 30 | 36.6 | 44.7 | 54.2 | |
Antarmuka tabung air | mm | DN20 | DN20 | DN20 | DN25 | DN40 | DN50 | DN80 | DN100 | |||||
Pelindung | 1\Perlindungan tekanan tinggi dan rendah, 2\perlindungan anti-beku, 3\proteksi temperatur, 4\katup pengaman, 5\perlindungan beban berlebih, 6\Fase mundur, 7\kurangnya fase, 8\pemisahan air dan listrik, dsb. |
|||||||||||||
Refrigerant | Tipe | R410a/R407c | ||||||||||||
Mode Throttle | katup ekspansi termostatik | |||||||||||||
berat | kg | 0.8 | 1.2 | 1.9 | 3 | 12 | 19 | 23 | 39 | 45 | 56 | 67 | 82 | |
Ukuran | Panjang | mm | 709 | 709 | 709 | 810 | 1760 | 2400 | 2400 | 2560 | 2560 | 2650 | 2890 | 2890 |
Lebar | mm | 359 | 359 | 359 | 420 | 500 | 650 | 650 | 880 | 900 | 900 | 900 | 1100 | |
Tinggi | mm | 592 | 592 | 592 | 590 | 1150 | 1210 | 1260 | 1300 | 1335 | 1430 | 1430 | 1530 | |
Noise (kebisingan) | ≤ dB(A) | 35 | 35 | 38 | 42 | 55 | 60 | 60 | 62 | 65 | 66 | 66 | 68 | |
Berat | kg | 43.8 | 45 | 69 | 93 | 340 | 570 | 612 | 850 | 1150 | 1300 | 1450 | 1850 | |
Catatan: 1, kondisi kerja pendinginan nominal tipe lingkaran bawah tanah: Temperatur saluran masuk/keluar air sisi pengguna 12/7; Temperatur saluran masuk/keluar air sisi sumber 25/30 | ||||||||||||||
Kondisi kerja pemanas nominal tipe lingkaran bawah tanah: Temperatur saluran masuk/keluar air sisi pengguna 40 45; Temperatur saluran masuk/saluran keluar air Sumber 10/ 5 | ||||||||||||||
2, kondisi kerja pendinginan nominal jenis air: Temperatur saluran masuk/keluar air sisi pengguna 12/7; temperatur saluran masuk/keluar air sisi sumber 18/29 | ||||||||||||||
Jenis air bawah tanah yang digunakan untuk pekerjaan pemanasan nominal: Temperatur saluran masuk/keluar air sisi pengguna 40 45; temperatur saluran masuk/keluar air | ||||||||||||||
3, kondisi kerja pendinginan tipe air Circle nominal: Temperatur saluran masuk/keluar air sisi pengguna 12/7; temperatur saluran masuk/keluar air dari sumber 30/35 | ||||||||||||||
Panas jenis air circle yang nominal telah terendam saat ini: Temperatur saluran masuk/keluar air sisi pengguna 40 45; temperatur saluran masuk/outlet air sisi sumber 20 | ||||||||||||||
4, kondisi kerja pendinginan standar: Temperatur saluran masuk/keluar air sisi pengguna 12/7; Temperatur saluran masuk/keluaran air Sumber 15/20 | ||||||||||||||
Kondisi kerja pemanasan standar: Temperatur saluran masuk/keluar air sisi pengguna 40/45; Temperatur saluran masuk/keluar air/10 | ||||||||||||||
5, parameter di atas yang berbasis Pendinginan (Pendinginan), untuk parameter yang berdasarkan kulkas lainnya, harap hubungi kami. | ||||||||||||||
6, parameter produk mungkin berbeda dengan produk akhir karena pembaruan produk, lihat label produk akhir saat membeli. Perusahaan kita terus berhak untuk menerjemahkan. |
Pemasok dengan izin usaha terverifikasi