Heat Temperature: | 40-60°c |
---|---|
Work Environment: | Common Heat Pump |
Heat Source: | Ground-source |
Heating Type: | Circulating Heat |
Application: | Villa Family |
Certification: | CE, ISO9001, CCC, SASO, TUV |
Pemasok dengan izin usaha terverifikasi
Pompa panas sumber ground Seri W02F untuk Pendinginan/Pemanasan | |||||||||||
Contoh | CRS13/S | CRS13/S | CRS19/S | CRS26/S | CRS38/S | CRS49/S | CRS76/S. | CRS91/S | CRS114/S | ||
(CS02W035S) | (CS02W035S) | (CS02W050S) | (CS02W070S) | (CS02W100S) | (CS02W140S) | (CS02W200S) | (CS02W240S) | (CS02W300S) | |||
Tipe air bawah tanah | Kapasitas pendinginan tetapan | KW | 13.5 | 13.5 | 19.1 | 26.1 | 38.1 | 52 | 76.10 | 91.50 | 114.20 |
Daya input tetapan untuk pendinginan | KW | 2.54 | 2.54 | 3.33 | 4.86 | 6.67 | 9.8 | 13.70 | 16.78 | 21.05 | |
Arus input tetapan untuk pendinginan | A | 12.81 | 4.7 | 6.93 | 9.72 | 13.61 | 19.5 | 27.22 | 32.66 | 40.83 | |
Koefisien kinerja pendinginan (cooling performance coefficient -) | / | 5.31 | 5.31 | 5.74 | 5.37 | 5.71 | 5.31 | 5.55 | 5.45 | 5.43 | |
Kapasitas pemanasan tetapan | KW | 12.8 | 12.8 | 18.2 | 25.6 | 36.2 | 51.3 | 72.30 | 86.80 | 108.40 | |
Daya input tetapan untuk pemanasan | KW | 2.98 | 3.4 | 4.16 | 5.95 | 8.42 | 11.95 | 16.98 | 20.68 | 25.49 | |
Arus input tetapan untuk pemanasan | A | 15.1 | 6.4 | 8.66 | 11.8 | 17.56 | 23.7 | 35.12 | 42.14 | 52.68 | |
Koefisien kinerja pemanasan (pemanasan, coefficient performance coefficient) | / | 4.30 | 4.30 | 4.38 | 4.30 | 4.30 | 4.29 | 4.26 | 4.20 | 4.25 | |
Gunakan aliran air heat exchanger samping | M3/j | 2.32 | 2.32 | 3.28 | 4.83 | 6.55 | 9.7 | 13.12 | 15.70 | 19.66 | |
Aliran air heat exchanger sisi sumber panas | M3/j | 1.32 | 1.32 | 1.87 | 2.75 | 3.72 | 5.50 | 7.46 | 8.91 | 11.18 | |
Loop tertutup sumber ground | Kapasitas pendinginan tetapan | KW | 12.98 | 12.98 | 18.36 | 25.01 | 36.63 | 50.00 | 73.30 | 87.85 | 109.50 |
Daya input tetapan untuk pendinginan | KW | 2.59 | 2.59 | 3.40 | 4.80 | 6.80 | 9.59 | 13.90 | 16.50 | 20.92 | |
Arus input tetapan untuk pendinginan | A | 12.33 | 4.30 | 7.23 | 10.39 | 14.48 | 20.80 | 28.98 | 34.78 | 43.50 | |
Koefisien kinerja pendinginan (cooling performance coefficient -) | / | 5.01 | 5.01 | 5.41 | 5.21 | 5.38 | 5.21 | 5.27 | 5.32 | 5.23 | |
Kapasitas pemanasan tetapan | KW | 8.7 | 8.9 | 12.51 | 17.5 | 25.1 | 34.9 | 50.10 | 59.90 | 74.80 | |
Daya input tetapan untuk pemanasan | KW | 3.21 | 2.95 | 4.15 | 6.01 | 8.42 | 12.02 | 16.95 | 20.80 | 25.85 | |
Arus input tetapan untuk pemanasan | A | 15.34 | 6.1 | 9.43 | 13.05 | 19.14 | 30.20 | 38.30 | 45.95 | 57.70 | |
Koefisien kinerja pemanasan (pemanasan, coefficient performance coefficient) | / | 2.71 | 3.02 | 3.01 | 2.91 | 2.98 | 2.90 | 2.96 | 2.88 | 2.89 | |
Gunakan aliran air heat exchanger samping | M3/j | 2.23 | 2.23 | 3.16 | 4.65 | 6.30 | 9.30 | 12.65 | 15.30 | 18.93 | |
Aliran air heat exchanger sisi sumber panas | M3/j | 2.79 | 2.79 | 3.95 | 5.81 | 7.87 | 11.60 | 15.85 | 18.92 | 23.65 | |
Catu daya | 220V/50Hz | 3N 380V/50Hz | |||||||||
Kompresor | Tipe | Tipe gulir tertutup penuh | |||||||||
Kuantitas | PC | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | |
Heat exchanger sisi sumber panas | Tipe | Heat exchanger & selubung | |||||||||
Ukuran pipa | DN | DN20 | DN20 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | |
Gunakan heat exchanger samping | Tipe | Heat exchanger & selubung | |||||||||
Ukuran pipa | DN | DN20 | DN20 | DN25 | DN25 | DN32 | DN32 | DN50 | DN65 | DN65 | |
Perlindungan | |||||||||||
Refrigerant | Tipe | R410A | |||||||||
Kuantitas | KG | 2 | 2 | 2.9 | 3 | 2.9x2 | 3.3x2 | 8x2 | 8,7x2 | 12x2 | |
Dimensi unit. | Panjang | MM | 810 | 810 | 810 | 810 | 1100 | 1100 | 1800 | 1800 | 1800 |
Lebar | MM | 420 | 420 | 420 | 420 | 840 | 840 | 1150 | 1150 | 1150 | |
Tinggi | MM | 590 | 590 | 590 | 590 | 800 | 800 | 1050 | 1050 | 1050 | |
Noise (kebisingan) | ≤DB(A) | 51 | 51 | 55 | 58 | 60 | 60 | 64 | 65 | 68 | |
Berat | KG | 115 | 115 | 120 | 180 | 190 | 700 | 730 | 780 | 850 | |
Catatan: | |||||||||||
1. Kondisi standar pendinginan tipe air di bawah tanah: Gunakan temperatur input/output air di samping 12/7; input air di sisi sumber/suhu output 18/29. Kondisi standar pemanasan tipe air bawah tanah: Gunakan suhu input/output air sisi 40/45C; input air sisi sumber/suhu output 15/-A. | |||||||||||
2. Kondisi standar pendinginan tipe loop tertutup di sumber tanah: Gunakan temperatur input/output air sisi 12/7; input air sisi sumber/suhu output 25/30 Temperatur standar pemanasan tipe lingkar tertutup di sumber: Gunakan input air sisi/suhu output 40 C/45 ; input air sisi sumber/suhu output 5celcius/A. | |||||||||||
3. "-a " berarti aliran air dalam kondisi standar pendinginan. | |||||||||||
Parameter di atas mungkin memiliki beberapa perbedaan dari produk akhir karena produk yang diperbarui, jadi informasi di atas bukanlah ketentuan kontrak bisnis. Harap lihat produk yang dapat dirayapi saat membeli, atau rujuk kami untuk informasi apa pun. Perusahaan kita terus berhak untuk menerjemahkan. |
Pemasok dengan izin usaha terverifikasi