Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Triple |
Principle of Work: | Vector Control Transducer |
Switch Mode: | Keyboard |
Main Circuit Type: | Current |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Pemasok dengan izin usaha terverifikasi
Pengoperasian | Mode kontrol | Terminal keyboard/ruang/ komunikasi RS485 | |||
Mode awal | Pembatasan arus/ beban tegangan/kebavy | ||||
Waktu mulai dan berhenti | Dapat disetel secara digital | ||||
Start delay | Dapat disetel secara digital | ||||
Stop darurat | Hentikan output starter lunak | ||||
Membatasi arus | Arus awal harus lebih rendah daripada arus pembatasan jika starter lunak beroperasi dengan pembatasan arus atau mode beban berat | ||||
Tegangan start | Tegangan start dapat disetel secara digital jika lunak starter beroperasi dalam mode tegangan | ||||
Kontrol beban | Kemungkinan untuk memeriksa kecelakaan termasuk sabuk tersandung | ||||
Mulai Ulang Otomatis | Mulai ulang otomatis setelah terjadi kerusakan | ||||
Output kerusakan | Output kontak AC 250V 1A ;DC30V 1A | ||||
Output relai multi-fungsi | Penundaan start, Mulai, Operasi,Hentikan, Mulai ulang mati penuh | ||||
Output analog | 0-20mA / 4-20mA tersedia | ||||
Fungsi Porteksi | Pemilihan starter lunak | Melindungi dari beban berlebih, arus berlebih, kepanasan, tiga fase tidak seimbang, fase hilang, saat pemuatan, kesalahan eksternal, dsb | |||
Peringatan starter lunak | Berhenti darurat,di bawah memuat,memulai ulang,dll | ||||
Tampilan | Keyboard A.S. | Informasi pengoperasian | Pengoperasian, peringatan stop dan kerusakan selama siaga, penundaan start, dan penyalaan | ||
Perlindungan | Lindungi parameter agar tidak dimodifikasi | ||||
Kondisi aplikasi | Kategori aplikasi | AC-53b | |||
Tegangan isolasi tetapan | 660V | Impuls tetapan tahan tegangan | 4KV | ||
Tingkat perlindungan | IP20 | ||||
Kondisi lingkungan | Suhu sekitar | -10 40 | |||
Suhu penyimpanan | -20 | ||||
Suhu penyimpanan | Maksimum90%RH(tanpa kondensasi) | ||||
Kelembapan sekitar | Di bawah 1000m;di bawah 5,9 m/dtk(=0,6 g) | ||||
Ketinggian/getaran | Tanpa gas korosif, gas mudah terbakar, kabut minyak, debu, atau lainnya | ||||
Pendinginan | Pendinginan udara alami |
CONTOH | Daya tetapan (KW) |
Arus tetapan (A) |
Pemutus arus yang kompatibel(QF) | KONTAKTOR bypass yang kompatibel(KM) | Spesifikasi kabel |
BZ1S23T4 | 11 | 23 | CM1-63L/32 | CJ20-25 | kabel 6mm2 |
BZ1S30T4 | 15 | 30 | CM1-63L/40 | CJ20-40 | kabel 10mm2 |
BZ1S37T4 | 18.5 | 37 | CM1-63L/40 | CJ20-40 | kabel 16mm2 |
BZ1S45T4 | 22 | 45 | CM1-63L/63 | CJ20-63 | kabel 16mm2 |
BZ1S60T4 | 30 | 60 | CM1-100L/80 | CJ20-63 | kabel 25mm2 |
BZ1S75T4 | 37 | 75 | CM1-100L/100 | CJ20-100 | kabel 35mm2 |
BZ1S90T4 | 45 | 90 | CM1-225L/125 | CJ20-100 | kabel 35mm2 |
BZ1S110T4 | 55 | 110 | CM1-225L/160 | CJ20-160 | kabel 35mm2 |
BZ1S145T4 | 75 | 145 | CM1-225L/180 | CJ20-160 | kabel 35mm2 |
BZ1S175T4 | 90 | 175 | CM1-225L/200 | CJ20-250 | 30*3mm2tembaga row |
BZ1S210T4 | 110 | 210 | CM1-400L/250 | CJ20-250 | 30*3mm2tembaga row |
BZ1S250T4 | 132 | 250 | CM1-400L/315 | CJ20-400 | 30*4mm2tembaga row |
BZ1S300T4 | 160 | 300 | CM1-400L/350 | CJ20-400 | 30*4mm2tembaga row |
BZ1S370T4 | 200 | 370 | CM1-400L/400 | CJ20-400 | 40*4mm2tembaga row |
BZ1S47T4 | 250 | 470 | CM1-630L/630 | CJ20-630 | 40*5mm2tembaga row |
BZ1S570T4 | 315 | 570 | CM1-800H/700 | CJ40-800 | 40*5mm2tembaga row |
BZ1S720T4 | 400 | 720 | CM1-800H/800 | CJ40-1000 | 50*5mm2tembaga row |
BZ1S840T4 | 450 | 840 | CM1-1250/1000 | CJ40-1000 | 50*5mm2tembaga row |
Tipe | Simbol | Nama | Deskripsi | |
Sirkuit utama | R,S,T | Input daya AC sirkuit utama | Sambungkan dengan catu daya 3 fase melalui pemutus arus | |
U,V,W | Terminal output dari starter lunak | Hubungkan dengan motor asinkron 3-fase | ||
L1,L2,L3 | Terminal khusus untuk kontaktor bypass eksternal | Sambungkan dengan kontaktor bypass | ||
Mengontrol catu daya | 12 | Terminal untuk input catu daya kontrol | Hubungkan dengan 220V AC, 50 Hz | |
13 | ||||
Sirkuit kontrol | Output relai |
1 | Terminal kontrol kontaktor bypass Bypass |
Tutup setelah mulai KAPASITAS AC 220V 5A |
2 | ||||
3 | Output relai kerusakan Berhenti |
Aktif selama kerusakan( beberapa modcs tersedia untuk dipilih) CapacitoAC 220V 5A |
||
4 | ||||
5 | Output relai multi-fungsi Jaringan |
Mode aktivitas yang dapat diprogram CapacitoAC 220V 5A |
||
6 | ||||
Input DIGITAL | 7 | Reset eksternal REAS | Sinyal stop darurat eksternal | |
8 | Terminal kontrol EMS untuk stop darurat | Sinyal reset eksternal selama kerusakan | ||
9 | Terminal penghenti kontrol eksternal yang melakukan Exteal | Di bawah Mode kontrol eksternal, ketika FUNGSI STOP dan COM ditutup,dan BERJALAN dan COM ditutup,operasi aktif.Jika tidak berhenti aktif. | ||
10 | Terminal operasi kontrol eksternal DIJALANKAN | |||
11 | Terminal COM dari COM sinyal eksternal | Terminal COM input digital | ||
RS485 Komunikasi |
A- | Sinyal positif dari 485 komunikasi | RS485komunikasi yang mulia | |
B+ | Sinyal negatif dari 485 komunikasi | |||
GND | GND teninal | Output 4-20mA atau 0-20mAanalog , yang dapat dipilih melalui pemrograman | ||
FM | Output termal sinyal saat ini |
Pemasok dengan izin usaha terverifikasi