Phase: | Single Phase |
---|---|
Type: | On-line |
Protection: | Unbalanced Loads |
Application: | Industry |
Classification: | Lighting/Power |
Standby Time: | Long-acting Machine |
Pemasok dengan izin usaha terverifikasi
MODEL UPS Online |
T1K/EX1K | T2K/EX2K | T3K/EX3K | T1KL/EX1KL | T2KL/EX2KL | T3KL/EX3KL | |
KAPASITAS | VA/W | 1000VA/800W | 2000VA/1600W | 3000VA/2400W | 1000VA/800W | 2000VA/1600W | 3000VA/2400W |
INPUT (MASUKAN) | Voltase Nominal | 110/115/120VAC atau 220/230/240VAC | |||||
Kisaran Tegangan | 60 VAC atau 115 VAC | ||||||
Rentang frekuensi | 50Hz: 46/ 54 Hz; 60Hz: 56 50Hz | ||||||
Fase | Fase tunggal dengan Ground (Ground) | ||||||
Faktor Daya | >=0.97 | ||||||
OUTPUT | Tegangan | 110/115/120*(1±2%)VAC atau 220/230/240*(1±2%)VAC | |||||
Frekuensi | 50/60Hz(dapat disetel) Mode AC 50Hz: Ikuti Mode AC (rentang AC 46 50Hz); Mode Baterai: 50Hz(1±0.2%) 60 Hz AC Mode (Mode AC): Ikuti Mode AC (AC Range56 Hz); Mode Baterai: 60 Hz(1±0.2%) |
||||||
Wave Form (Formulir Gelombang) | Gelombang Sinus murni | ||||||
Faktor Daya | 0.7 | ||||||
Distorsi Harmonik | <3% THD (Beban Linear), <7% THD (Beban Non-Linear) | ||||||
Kapasitas Beban Berlebih | 110% 150 memelihara 30% dan berubah menjadi bypass output, lebih dari 150% memelihara 200ms | ||||||
Rasio Crest saat ini | 3:1 | ||||||
Koneksi | IEC320*4 | IEC320*6 | IEC320*3 & blok Terminal | IEC320*4 | IEC320*6 | IEC320*3 & blok Terminal | |
Efisiensi | Ke AC Mode (Mode AC) | 85% | |||||
Ke Battery Mode (Mode Baterai) | 83% | ||||||
Baterai | Tipe | Baterai asam timbal perawatan bebas dengan seal | |||||
Voltase DC nominal | Baterai terpasang 12 v7,2 ah | 36VDC | 96VDC | 96VDC | |||
Kuantitas | 3 potong | 8pcs | 8pcs | Tergantung waktu cadangan yang diminta | |||
Waktu cadangan (Beban penuh) |
>=7 menit | >=8 menit | >=6 menit | Tergantung pada kapasitas bank baterai eksternal | |||
Waktu pengisian ulang | 5jam hingga 90% dari kapasitas pengosongan penuh | Tergantung pada kapasitas bank baterai eksternal | |||||
Arus pengisian(MAKS) | 1,0A | 1,0A | 1,0A | 7A | 8A | 8A | |
Tegangan pengisian | 41,1Vdc ± 0,6V | 110Vdc ± 0,4V | 41,1Vdc ± 0,6V | 110Vdc ± 0,4V | |||
Bypass | Transfer Otomatis | Beban berlebih dan kegagalan UPS | |||||
Sebelum Daya UPS dinyalakan | Default "TIDAK" dapat disesuaikan pengguna ke "YA" | ||||||
Waktu transfer | 0ms, kurang dari 4ms dari inverter ke bypass dan sebaliknya | ||||||
Indikator | Layar LCD | Status UPS, voltase I/P & O/P& frekuensi, Tegangan baterai, Kapasitas baterai, memuat, Kode kerusakan | |||||
Alarm Suara | Bypass, pada mode baterai, Baterai lemah, Beban Berlebih, kerusakan | ||||||
Noise akustik | Pada jarak 1 meter | <45dB | <50dB | <50dB | <45dB | <50dB | <50dB |
Komunikasi mereka | Port seri RS232 cerdas | Perangkat lunak mendukung perangkat lunak keluarga Windows, Linux, sistem operasi jaringan Sun, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX DAN MAC | |||||
SNMP (Opsional) | UPS kontrol jarak jauh melalui manajemen SNMP dan Internet | ||||||
USB (Opsional) | Perangkat lunak keluarga Windows dan Mac OS | ||||||
Perlindungan lonjakan Jaringan | Port RJ45 I/O tersedia untuk jaringan atau saluran FAKS/telepon/Modem | ||||||
Lingkungan | Suhu Pengoperasian | SBP 0-40 C | |||||
Kelembapan Pengoperasian | 20 90% (Non kondensasi) | ||||||
Berat | Berat bersih (kg) | 14 | 31.5 | 32 | 7 | 13.5 | 14 |
Dimensi UPS | L*W*T (MM) | 400*145*220 | 460*192*348 | 460*192*348 | 400*145*220 | 460*192*348 | 460*192*348 |
MODEL UPS Online |
DX6K | DX10K | DX6KL | DX10KL | DX3110KL | DX3115KL | DX3120KL | |
KAPASITAS | VA/W | 6KVA/4,8KW | 10KVA/8KW | 6KVA/4,8KW | 10KVA/8KW | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
INPUT (MASUKAN) | Voltase Nominal | 220/230/240VAC | 380VAC | |||||
Kisaran Tegangan | 120-275VAC | 210-475VAC | ||||||
Rentang frekuensi | 46-64Hz: 50Hz, 60Hz otomatis | |||||||
Fase | Fase tunggal dengan Ground (Ground) | Tiga fase (4 Kabel+Ground) | ||||||
Faktor Daya | >=0.99 | >=0.95 | ||||||
OUTPUT | Tegangan | 220/230/240*(1±1%)VAC | ||||||
Frekuensi | 50/60Hz(dapat disetel) Mode AC 50Hz: Ikuti Mode AC (rentang AC 46 50Hz); Mode Baterai: 50Hz(1±0.1%) 60 Hz AC Mode (Mode AC): Ikuti Mode AC (AC Range56 Hz); Mode Baterai: 60 Hz(1±0.1%) |
|||||||
Wave Form (Formulir Gelombang) | Gelombang Sinus murni | |||||||
Faktor Daya | 0.8 | |||||||
Distorsi Harmonik | =<2% THD (Beban Linear), =<6% THD (Beban Non-Linear) | |||||||
Kapasitas Beban Berlebih | Normal saat memuat < 105%; 105%-125% selama 1 mnt, 125%-150% untuk 30 dtk | |||||||
Rasio Crest saat ini | 3:1 | |||||||
Koneksi | Blok terminal | |||||||
Efisiensi | Ke AC Mode (Mode AC) | 88% | 85% | |||||
Ke Battery Mode (Mode Baterai) | hingga 90% | |||||||
Baterai | Tipe | Baterai asam timbal perawatan bebas dengan seal | ||||||
Voltase DC nominal | Baterai bawaan 12 v7,2ah*16pcs | 192VDC | 192VDC | |||||
Kuantitas | 16 potong | 16 potong | Tergantung waktu cadangan yang diminta | Tergantung waktu cadangan yang diminta | ||||
Waktu cadangan (Beban penuh) | >=7 menit | >=5 menit | Tergantung pada kapasitas bank baterai eksternal | Tergantung pada kapasitas bank baterai eksternal | ||||
Waktu pengisian ulang | 7 jam hingga 90% | Tergantung pada kapasitas bank baterai eksternal | Tergantung pada kapasitas bank baterai eksternal | |||||
Arus pengisian(MAKS) | 2.0A | 4,2A atau 8A | 4,2A atau 8A | |||||
Tegangan pengisian | 220Vdc ± 1% | |||||||
Bypass | Transfer Otomatis | Beban berlebih dan kegagalan UPS | ||||||
Sebelum Daya UPS dinyalakan | Default "TIDAK" dapat disesuaikan pengguna ke "YA" | |||||||
Waktu transfer | Nol | |||||||
Indikator | Tampilan LED | Status UPS, voltase I/P & O/P& frekuensi, Tegangan baterai, Kapasitas baterai, memuat, Kode kerusakan | ||||||
Alarm Suara | Bypass, pada mode baterai, Baterai lemah, Beban Berlebih, kerusakan | |||||||
Noise akustik | Pada jarak 1 meter | <55dB | <60dB | |||||
Komunikasi mereka | Port seri RS232 cerdas | Windows 98/NT/2000/XP/2003, Linux, Sun Solaris, IBM Aix, Compaq True64, SGI IRIX, FreeBSD, HP-UX, dan MAC | ||||||
SNMP (Opsional) | Manajemen daya dari manajer SNMP dan browser web | |||||||
USB (Opsional) | Perangkat lunak keluarga Windows dan Mac OS | |||||||
Lingkungan | Suhu Pengoperasian | 0-40 | ||||||
Kelembapan Pengoperasian | 20 90% (Non kondensasi) | |||||||
Berat | Berat bersih (kg) | 57 | 67.5 | 18 | 20 | 27 | 35 | 35 |
Dimensi UPS | L*W*T (MM) | 500*248*616 | 500*248*616 | 500*240*460 | 500*240*460 | 500*248*616 | 500*248*616 | 500*248*616 |
Ada dua jenis: Tipe standar dan Tipe profesional, Tipe profesional dengan EPO, pemeliharaan online, dan fungsi lainnya. |