Type: | Head Mounted Temperature Transmitter |
---|---|
Measuring Medium: | Temperature |
Site Display: | Not Site Display |
Accuracy: | 0.1 |
Certification: | CE |
Customized: | Customized |
Pemasok dengan izin usaha terverifikasi
Input (masukan) | |
Sinyal input | Detektor temperatur resistan (RTD, Resistance temperature temperature detektor), TERMOKOPEL (TC), dan resistan linear. |
Lingkup temperatur kompensasi persimpangan-dingin | -20 DERAJAT CELCIUS |
Presisi kompensasi | ±1CELCIUS |
Output | |
Sinyal output | 4-20mA |
Resistan beban | RL≤(Ue-12)/0.021 |
Arus output alarm luapan batas atas dan bawah |
IH=21mA,IL=3,8mA |
Catu daya | |
Tegangan catu daya | DC12-40V |
Parameter lainnya | |
Pergeseran suhu | 0.02%FS/ (Standar) |
0.0075%FS/ (terisolasi) | |
Waktu Respons | Jangkauan hingga 90% dari nilai akhir untuk 1 |
Temperatur lingkungan yang digunakan | -40 CELCIUS |
Suhu penyimpanan | -40 CELCIUS |
Micheitas | 4g/2 Masuk 150Hz |
Sudut pemasangan | Tak terbatas |
Area instalasi | Pemasangan kaset atas jenis B. |
Kompatibilitas elektromagnetik | Sesuai dengan GB/T18268 peralatan industri Persyaratan aplikasi (IEC 61326-1) |
Tipe terisolasi | |
Kekuatan insulasi (antara input dan output) | 1500 Vrms (1 mnt, tanpa bunga) |
Resistan isolasi (antara input dan output) | ≥100MΩ(di bawah 500 VDC) |
Contoh | Tipe | Pengukuran lingkup |
Minimum lingkup pengukuran |
Rentang skala | Akurasi konversi |
Detektor temperatur resistan (RTD, Resistance temperature detektor) | Pt100 | -200.0 CELCIUS RP. | 10 | ≤100 DERAJAT CELCIUS | 0.20% |
> 100 DERAJAT CELCIUS | 0.10% | ||||
CU50 | -50.0 CELCIUS | 10 | ≤100 DERAJAT CELCIUS | 0.20% | |
> 100 DERAJAT CELCIUS | 0.10% | ||||
TERMOKOPEL (TC) | B | 400 DERAJAT CELCIUS | 500 DERAJAT | ≤300 | 0.20% |
300 DERAJAT CELCIUS | 0.10% | ||||
E | -100 1.000 CELCIUS | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
J | -1 -1200 100 ORANG | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
K | -180 | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
N | -180 CELCIUS | 50 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
R | -50 CELCIUS | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
S | -50 CELCIUS | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
T | 200 DERAJAT CELCIUS | 50 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
Mengubah 3an3-25 | 0 | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
Wre5-26 | 0 | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% |
Contoh | Tipe | Pengukuran lingkup |
Minimum lingkup pengukuran |
Rentang skala | Akurasi konversi |
Detektor temperatur resistan (RTD, Resistance temperature detektor) | Pt100 | -200.0 CELCIUS RP. | 20 DERAJAT CELCIUS | ≤100 DERAJAT CELCIUS | 0.20% |
> 100 DERAJAT CELCIUS | 0.10% | ||||
CU50 | -50.0 CELCIUS | 20 DERAJAT CELCIUS | ≤100 DERAJAT CELCIUS | 0.20% | |
> 100 DERAJAT CELCIUS | 0.10% | ||||
TERMOKOPEL (TC) | B | 400 DERAJAT CELCIUS | 500 DERAJAT | ≤300 | 0.20% |
300 DERAJAT CELCIUS | 0.10% | ||||
E | -100 1.000 CELCIUS | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
J | -1 -1200 100 ORANG | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
K | -180 | 50 DERAJAT | ≤300 | 0.20% | |
300 DERAJAT CELCIUS | 0.10% | ||||
N | -180 CELCIUS | 50 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
R | -50 CELCIUS | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
S | -50 CELCIUS | 500 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% | ||||
T | 200 DERAJAT CELCIUS | 50 DERAJAT | ≤500 | 0.20% | |
> 500DERAJAT | 0.10% |
Pemasok dengan izin usaha terverifikasi