Kapasitor Tegangan Tinggi
Referensi Harga FOB: | US$4.000 / Bagian |
---|---|
Pesanan Minimum: | 1 Bagian |
Pesanan Minimum | Referensi Harga FOB |
---|---|
1 Bagian | US$4.000/ Bagian |
Kapasitas Produksi: | 1000sets/Month |
---|---|
Paket Transportasi: | Wooden Pack |
Ketentuan Pembayaran: | L/C, T/T., D/P |
Deskripsi Produk
Informasi Perusahaan
Informasi dasar.
Tidak. Model.
WVP
Type
Ceramic Trimming Capacitor
Application
General Purpose, AC / Motor, Power, Lighting, Air Conditioner, High Voltage, Fan, Automobile
Packaging Type
Surface Mount
Capacitance
>100uf
Structure
Variable Capacitor
Manufacturing Material
Electrolytic
Electrolyte
Electrolytic
Usage
High Frequency Coupling
Tuning
Ceramic Capacitor
Filter
Aluminum Electrolytic Capacitor
Power Factor of Motor
Reaching up to 0.95
IP
IP20 IP30
Merek Dagang
WORLDSURE
Spesifikasi
CE ISO CCC
Asal
Hubei Xiangyang
Deskripsi Produk
perangkat statis SVP seri WVP telah lulus pemeriksaan mutu ketat dan pengujian kinerja sebelum ex-factory. Setelah sampai di lokasi pemasangan, harap periksa apakah ada kerusakan karena ceroboh transportasi, dan apakah model produk sesuai dengan yang dipesan sebelum mengeluarkan bahan dari kemasan. Karena produk terus-menerus ditingkatkan, mungkin ada beberapa bagian atau kata-kata dari peralatan dan produk, yang tidak sesuai dengan bahan periklanan; silakan berkonsultasi dengan kami jika peralatan memenuhi masalah tersebut. Setelah membuka kotak, periksa apakah ada tanda yang memenuhi syarat, keterangan produk, buku panduan garansi produk, dan daftar kemasan dalam kotak dokumen di pintu depan kabinet peralatan. Jika terjadi masalah, hubungi kami atau pemasok.
1. Periksa apakah informasi yang terpasang pada peralatan sudah lengkap dan sesuai dengan isi daftar kemasan
peralatan.
2. Periksa pelat nama pada bodi kabinet untuk memastikan bahwa peralatan sesuai dengan peralatan pesanan
Seri WVP2 menguat statis staf saran
WVP 2 - 600G jenis
Daya Motor: 240 KW : W900*D800*SS*H2000
Motor Rotor Arus 442A N.W.:
20908474 Tanggal Produksi: Agustus 2005
: Aplikasi 1697-2005: Rolling mill bekerja di stand:Q/XWZEI
ELECTRIC GROUP CO., LTD menambahkan
: #1 Worldwide Road Xangyang City, Hubei Province
3. Periksa apakah suku cadang dan komponennya rusak atau hilang. Suku cadang dan komponen cadangan diatur dengan kontrak pengadaan.
Kondisi penggunaan
peralatan elektronik standar yang berlaku yang dilengkapi dengan peralatan kontrol elektronik GB3797-1989
Tegangan Tetapan
AC 3-fase 380V+10%
Daya kontrol
yang diperlukan untuk menyediakan
frekuensi catu daya tiga-kabel
2%
Motor
75KW. 10000KW Kontrol Struktur Pengaman
Tipe Struktur Pengaman Tipe
Platform kumparan lilitan
,
suhu lingkungan IP20
-40 +50C
tidak lebih kelembapan relatif
Ketinggian kerja di atas 90%
tidak lebih dari 2000 mm(Jika lebih dari 2000 mm, bisa didesain khusus sesuai kondisi
Ventilasi tertentu
tidak boleh ada benda lain 500 mm di atas kabinet, misalnya, selokan tertutup, alat saran statis harus overhead 100 mm.
Tidak
boleh ada kebakaran, tidak ada ledakan, tidak
ada peringatan korosi kimia dan Keselamatan Getaran yang berat!
Bebas dari penanganan atau pemasangan rasff, gangguan hujan dan elektromagnetik.
Peringatan!
Cegah anak-anak dan masyarakat untuk tidak menyentuh atau mendekati peralatan ini. Peralatan ini, dengan tegangan yang berbahaya, mengontrol
Peringatan mekanisme putar yang berbahaya!
Peralatan ini hanya boleh digunakan untuk tujuan yang telah ditentukan oleh produsen; modifikasi apa pun tanpa otorisasi atau operasi yang tidak sesuai dengan peraturan
dalam buku panduan ini akan mengakibatkan cedera diri yang parah dan cedera lainnya.
Peringatan!
Baca petunjuk pengoperasian pemasangan dan keselamatan perawatan dalam buku petunjuk ini dengan saksama
sebelum mengoperasikan peralatan ini.
Umum
di Cina, energi listrik yang digunakan oleh motor meningkat hingga 60% 68 dari semua konsumsi energi industri. Konsumsi Reinduktif yang disebabkan karena beban induktif seperti motor adalah sumber utama konsumsi jaringan listrik yang reaktif, tetapi motor besar dan menengah adalah perangkat tenaga utama yang digunakan dalam perusahaan industri dan pertambangan. Jadi, cara mengurangi konsumsi reaktif yang disebabkan motor ukuran besar dan menengah adalah kunci penghematan energi dan penurunan konsumsi dari banyak perusahaan industri dan pertambangan.
Sementara itu, karena sebagian besar beban motor tidak konstan, beban berubah-ubah sangat bertekstur, dan bahkan memuat mutasi, seperti rolling mesin dan memukul alat berat dengan tahap steeloads, pemberontak dalam industri kayu, menghancurkan mesin pada industri gula dan peralatan crusher di tambang.dalam hal ini, Bila kita menggunakan kapasitor untuk kompensasi daya reaktif, kapasitor akan memberikan kompensasi atau kurang, karena kompensasi kapasitor hanya memberikan kompensasi reaktif untuk jaringan listrik kecuali motor, yang dapat mengurangi jumlah transmisi pada jaringan listrik, tetapi parameter pengoperasian motor itu sendiri seperti arus motor, faktor daya dan seterusnya tidak mengalami perubahan sama sekali. Jika kompensasi kapasitor diambil dalam kondisi layanan itu, jumlah kompensasi tidak dapat berubah ketika beban motor berubah, dengan demikian, kompensasi yang kurang atau kurang akan terjadi dan penggunaan keandalan kapasitor akan dengan mudah dikurangi karena perbedaan arus motor dan letupan yang mendadak dapat terjadi. Jika saran statis biasa saja diambil, kompensasi akan berlebihan atau tidak cukup baik, karena staf yang biasa memberi saran tidak dapat digunakan secara normal karena terlalu berat atau terlalu rendah beban.
Lembaga penelitian ilmiah baik di atas maupun di rumah selalu menerima kompensasi berbagai kondisi pelayanan sebagai masalah yang sulit dihadapi, namun dengan hasil yang cukup sedikit. Perusahaan kami mengorganisir para peneliti yang mengembangkan alat saran statis yang disebut WVP digunakan dalam situasi variasi beban selama dua tahun dengan basis penelitian dan penerapan kompensasi daya reaktif selama bertahun-tahun. Sistem ini berhasil mengatasi masalah yang sulit pada kompensasi daya reaktif dalam kondisi servis berbagai beban.
Staf saran statis seri WVP juga berbeda dari eksitasi sendiri (diputar) saran. Staf anti statik seri WVP mengadopsi teknologi frekuensi bergantian tingkat lanjut dan teknologi kontrol silikon yang dapat melacak status aktif motor eksitasi dan mengubah parameter relatif secara otomatis untuk mendapatkan efek sempurna yang tidak dapat dilakukan oleh eksitasi sendiri. Lebih jauh lagi, staf saran statis seri WVP sudah terlalu sering memberi fasilitas debu, masa pakai yang pendek, perawatan kerap dengan struktur "komutator" dari saran kanker mandiri. Tidak ada bagian yang bisa diputar dari mekanisme advancer, tahan debu, sangat andal, nyaman untuk perawatan dan dengan masa pakai lama, yang merupakan produk canggih ideal untuk menggantikan eksitasi sendiri.
Saran statis seri WVP digunakan secara luas untuk kompensasi di lokasi motor asinkron yang besar dan sedang terjadi di ladang semen, industri kimia, kayu, gula, besi dan baja, metalurgi, pertambangan, dan sebagainya.
II. Prinsip pengoperasian
WVP seri advancer statis terhubung pada loop rotor, melihat status pengoperasian motor dengan menghubungkan arus operasi motor, sinyal tegangan, Dan perlakukan informasi ini dan sinyal arus rotor dari sensor arus rotor serta sinyal sinkronisasi dari tegangan frekuensi daya dalam SCM pada saat yang sama, sesuaikan jumlah kompensasi secara otomatis sesuai pengoperasian motor, sadari kompensasi otomatis. secara tepat waktu, memberi urutan pemicu yang diperbesar oleh papan pemicu untuk mengontrol perangkat frekuensi alternatif yang terdiri dari 12 thistor, untuk mengubah catu daya frekuensi ke frekuensi arus rotor yang sama dan menerapkan posisi fase canggih pada loop motor. Mengubah hubungan fase antara arus dan tegangan rotor, semakin mengubah arus stator dan hubungan fase tegangan melalui medan magnetik, sehingga dapat mengurangi faktor daya, Dan akhirnya, tambah faktor daya motor, kurangi arus stator, untuk merealisasikan kompensasi
saat motor berjalan pada beban, arus rotor-nya I2e, dan arus stator I1e. Diagram vektor ditunjukkan sebagai berikut:
Dalam diagram:
U:vektor voltase
I1:vektor saat ini stator
I2:vektor arus rotor
IM:vektor Mwaktu saat ini di lapangan
I1e:
vektor peringkat stator I2e:vektor yang saat ini dinilai saat ini adalah
Φ1: Φ2 sudut faktor daya setelah mengompensasi
dari mekanik yang kita tahu bahwa arus di lapangan IM dapat diperoleh melalui IM=I1e-I2e,dan IM juga dapat diperoleh dari diagram vektor. Setelah potensi listrik alat saran statis ditumpangkan pada loop rotor, posisi fase penggantian arus rotor ke I2 dalam diagram. Bidang saat ini IM tidak berubah karena pemuatan tidak berubah. Sekarang, stator yang sedang digunakan harus diperoleh sesuai dengan I1=IM+I2 sebagai diagram vektor yang ditunjukkan di atas. Dari diagram ini kita dapat melihat bahwa sudut faktor daya dan nilai amplitudo I1 semuanya lebih kecil daripada I1e, yang menunjukkan faktor daya motor meningkat dan arus stator berkurang.
Jadi kita dapat melihat perbedaan mendasar antara staf statis seri WVP yang memberikan saran-saran daya reaktif untuk kompensasi daya motor dan kompensasi sisi stator motor kapasitor parallel Diagram skematis kompensasi kapasitor dan saran statis, kompenser adalah sebagai berikut:
Pada diagram, motor bersifat disederhanakan, dan R1, X1 adalah resistansi dan induktansi sirkuit setara stator motor; R2, X2 resistan dan induktansi sirkuit setara rotor dari motor; C adalah kapasitas berkompensasi di lokasi; Uf adalah sirkuit yang setara dengan alat pencanggih; M adalah antarmuka kabel motor.
Kita dapat melihat dari diagram:Kompensasi kapasitas memiliki fungsi untuk memasok motor dengan daya reaktif dan mengurangi input reaktif jaringan listrik dengan mengurangi daya reaktif yang diserap jaringan listrik oleh motor guna meningkatkan faktor daya jaringan listrik. Namun konsumsi daya motor tidak berkurang dan arus stator motor dan faktor dayanya tidak berubah, yaitu tidak ada perubahan status pengoperasian motor. Fungsi penggantian alat saran statis menambah catu daya tambahan dalam loop rotor dan mengubah hubungan posisi fase antara arus rotor dan tegangan rotor, selain mengubah hubungan posisi fase antara arus stator dan tegangan stator oleh medan magnetik untuk mengurangi konsumsi reaktif motor. Dengan cara ini, status motor yang sedang berjalan diubah, dan arus stator berkurang, sehingga faktor daya jaringan listrik bertambah karena faktor daya motor sendiri meningkat. Selain itu, pengurangan arus stator menurunkan kerugian tembaga motor, dan meningkatkan efisiensi motor serta temperatur turun motor. Kapasitas beban berlebih ini juga ditingkatkan dan produk jam alat berat meningkat, sementara konsumsi tunggal berkurang.
III. Karakteristik kinerja
perangkat statis serial WVP merupakan hasil berteknologi tinggi untuk daya reaktif pada kompensasi lokasi motor lilitan besar atau sedang, yang berlaku hingga 75 deret motor asinkron luka 10000kW. Kinerja yang sangat baik khususnya ditunjukkan dalam aspek berikut:
1) mengatasi masalah sulit ganti rugi di lokasi motor dengan variasi beban, yang mengisi teknologi dan produk kosong di area ini.
2) Pilih teknologi frekuensi bolak-balik dan teknologi kontrol mikro canggih, dengan keandalan tinggi.
3) faktor daya motor hingga 0.95:0.99,daya reaktif turun hingga kurang dari 60%.
4) arus stator motor turun hingga 10% 20,penurunan kabel, penurunan tembaga hingga 20%-30%.
5) penurunan suhu motor yang Rapid, peningkatan efisiensi dan kapasitas beban berlebih yang sangat besar, masa pakai motor yang lama.
6) Kinerja Kompensasi lebih tinggi daripada kompensasi kapasitansi: Tidak hanya meningkatkan faktor daya sirkuit, tetapi juga meningkatkan faktor daya pada motor itu sendiri.
7) performa bundar lebih baik dari sekadar alat saran yang diputar: Dikontrol oleh komputer mikro dan dapat secara otomatis melacak keadaan berjalan motor dan secara otomatis mengubah parameter relatif untuk mendapatkan efek sempurna; kemampuan tinggi untuk beradaptasi dengan lingkungan karena tidak ada bagian yang lari.
8) Kinerja Kompensasi jauh lebih baik daripada yang biasa naik oleh fase statis dalam kondisi beban variabel: Kontrol CPU ganda, dapat menyesuaikan parameter secara tepat waktu sesuai dengan perubahan beban, untuk mencapai tujuan kompensasi yang dinamis, menjadikan faktor daya selalu dalam
9 antarmuka manusia-alat berat yang ramah, kemudahan operasi, kesulitan yang secara otomatis melindungi fungsi, perawatan tanpa mengganggu produksi.
IV Parameter teknis
1. Indeks kinerja
l meningkatkan faktor daya motor ke 0.95 atau lebih (atau menambah 20% atau lebih)
l menurunkan arus stator motor ke 10%-20%
l menurunkan kenaikan temperatur kumparan motor ke 10% atau lebih
2.
Input dan Input Parameter output:
Sinyal l dari arus stator motor(01,04): Output sinyal 0 5A standar dari transformer arus fase tertentu.
Sinyal l tegangan stator motor(05, 06): Output sinyal sinyal tegangan standar 100V dari tegangan kabel dua fase melalui transformer tegangan untuk motor tegangan tinggi; Output sinyal standar 380V dari tegangan-kabel dua-fase yang langsung menuju ke depan untuk motor
l tegangan rendah: Sinyal arus stator motor tidak akan sama dengan salah satu tegangan stator. Dengan kata lain, sinyal tegangan hanya boleh berupa fase B atau fase C jika sinyal saat ini adalah fase.
Sinyal Selesai Start l(W,111):berasal dari sinyal hubung-singkat rotor starter, yang biasanya disuplai oleh kontaktor hubung-singkat titik-bintang. Sinyal ini diperlukan untuk disimpan dan kapasitas kontak adalah 5A, 380V.
Output:
l Start Allowable(Ready)Signal(121,123): Sinyal ini digunakan untuk interlock kabinet primer motor, yang menggabungkan dalam loop tombol start. Kapasitas kontak ini
adalah sinyal AC380, 5A. L Stop (trip)(125, 129)dan(131,133):sinyal ini digunakan untuk interlock kabinet primer motor, memilih salah satu dari dua sinyal sesuai dengan kondisi yang berbeda: (125, 129) untuk sakelar perjalanan listrik pemutus arus. Sistem penyambungan paralel dengan tombol stop;(131, 133) untuk sakelar perjalanan elektrik jenis kontaktor. Gabung dengan tombol stop. Kapasitas kontak adalah 5A, 380V.
3. Catu daya layanan
WVP Series EGadvancer statis memerlukan perangkat eksternal untuk menyuplai suplai daya empat kabel tiga fase. Kapasitas di bawah:
Kapasitas spesifikasi tipe kapasitas
pasokan daya area bagian kabel
WVP2-400 tipe
6 mm2
WVP2-600 tipe
20A
6 mm2
WVP2-800jenis 25A
6 mm2
WVP2-1000 tipe
30A
10 mm2
WVPe2-1200 tipe
40A
10 mm2
Wmm2 W5mm2-1400 tipe
50mm2 W5mm2 W5mm2 WPL
-
1600 jenis
16- jenis 50mm2 WPL- jenis 50mm2 WPL-- jenis 50mm2 jenis jenis- jenis
Metode pemilihan tipe V.
5.1. Petunjuk model
W VP
C: Dengan PLC Z: Dengan DCS
G (D):cocok untuk motor tegangan tinggi (rendah)
Nomor desain rotor maks. Beban
yang berubah-ubah perangkat statis penggerak Shari Sedunia
5.2 meja
saran Statis model
perangkat adaptif
aliran arus (A)
rotor tetapan (A)
WVP2-
400D
≤420
≤245
380
W5S5405-
≤420
≤245 VP51260
≥
-
380 3000
WVP2-600G
-5-2000
-2001
≥3000
WVP2-800D
560-4.000
HINGGA 1250
380
WVP2-800G
-800-1500 560-5700051.5 -50
≥3000
3000-VP002 -1.2 -1.917 -000,00 ≥-650
3000 ≥V50 3000 3000 ≥-≥-51.2-4VP000,00 3000 ≥3000 ≥
WVP2-1200G menunjukkan bahwa alat adver statis sesuai untuk motor yang arus rotor tidak lebih dari 1200 A,
Pada penukar
-penukar penukar penukar penukar penukar penukar penukar ASCII pada penukar ASCII biasa
saja pada para penukar ASCII 6.1
-VP2D-900 pada penukar ASCII 760-2000 600 VP2V-VWVWVWVP2-640-1000 VWVP2D-800 Halaman 700-VP2V 2000 600-VWVWVWVWVWV 1200-960 Halaman 2000 900-VWVWVP2D-VWVWVWVWVWVWVWVWVWV 840-1300
1400
-Halaman 1060-2200 1000 1160-VWVWVWVWVWVWVWV 940 2200 1200 1040
² Perangkat harus dipasang dengan aman dan erat.
² sebelum digunakan, pastikan peralatan tersebut benar dan dapat diandalkan sesuai dengan persyaratan keselamatan listrik nasional dan standar lain yang terkait.
² Jika terjadi kecelakaan, terminal pembumian harus terhubung ke ground dengan baik, jika tidak, sengatan listrik dapat terjadi
6.2. Sketsa kabel dan peringatan
pemasangan perangkat statis WVP bisa dihubungkan ke ground dengan benar sesuai modus perkabelan yang ditampilkan pada sketsa di bawah.
Catatan:
² meminimalkan kontaktor dan relai elektromagnetik, serta sumber interferensi lain yang dekat dengan alat saran.
² saat sirkuit utama kabel, ukuran harus dipilih sesuai dengan persyaratan keselamatan listrik nasional.
² Arus motor dan rotor tidak boleh melebihi kapasitas tetapan dari alat saran statis
² Peralatan kabel harus terhubung dengan saluran kontrol dalam, kemudian daya.
² saat perangkat dialiri daya, jangan menyentuh papan sirkuit internal dan komponen, jika terjadi kejutan listrik.
² saat pemutusan daya, jangan menyentuh papan sirkuit dalam dan suku cadang dengan segera.
Tombol
instruksi fungsi tombol Panel Operasi VII 7.1
-tekan tombol ID
Key-press name instruction
Set key (ID Kunci)
1. Tekan tombol ini untuk mengatur parameter
2. Tekan tombol ini untuk melihat kode fungsi berikutnya dan
tombol penambahan Parameter
meningkatkan jumlah saat mengubah
tombol potongan parameter
mengurangi jumlah saat mengubah parameter
dalam fase
dalam tombol fase, tekan tombol ini untuk fase
ke arah fase out
tombol fase
, tekan tombol ini Untuk keluar
diagram fase 7.2 Aliran dari parameter pengontrol
Tabel fungsi Setelan parameter Pengontrol 7.3: Tabel fungsi
pengaturan nilai
Kode instruksi Pabrik
P01
metode kerja Pengontrol
0,1
0
0:tanpa mengembalikan fungsi perbedaan
1:dengan fungsi Return Difference P02
koreksi kesalahan tampilan -50-50 -50
0
kesalahan kecil
dari rasio transformer P03 arus
--2000
CT 200, Dari nilai default 5A,
motor beban ringan P04 dan motor beban sekunder
0-2000
50
P01 ditetapkan ke 0, menunjukkan kondisi pengoperasian motor yang menentukan arus ambang; P01 ditetapkan ke 1, Mengatakan kondisi pengoperasian motor menentukan ambang batas minimum histeresis
P05
arus motor kelebihan beban
0-2000 hanya
100
berlaku bila P01 ditetapkan ke 1, Menunjukkan kondisi pengoperasian motor menentukan batas arus ambang batas hysteresis
P06
Password Setting
(Pengaturan Kata Sandi) 0-2000
0
pilihan untuk parameter
P07
Phase valid
0-2000
0
P07) arus motor saat fase <P04 dalam fase tidak valid; nilai arus motor saat dimasukkan
7.4 Instruction of function parameters
1. Controller work method (function code P01)
Controller has two work modes:P01 can be set to (0,1).
"0" means no return difference function, that's to say, the judgment of motor operation is according to P04, if motor operation current is more than P04, it is overload, if less than P04, it is light-load
"1" means with return difference function, that's to say, the judgment of motor operation is according to both P04 and P05, when motor operation current is more than P05, it is overload, when less than P04, it is light-load
2. Current display error correction (function code P02)
It is mainly used for correcting the error between the controller display current and the motor running current, correction range is (-50A ~ +50 A).
3. Transformer ratio (function code P03)
Setting this parameter according to the current signal taken from the primary current transformer, and the default secondary side is rated 5A
4. Motor light load current (function code P04)
When P01 is set to 0, this parameter indicates the threshold current which shows the judgement of motor operation. When P01 is set to 1, this parameter represents the threshold current return difference lower limit of motor operation
5. Motor over load current (function code P05)
This parameter is valid only when P01 is set to 1, it indicates the threshold current return difference upper limit of motor operation
6..Password setting (function code P06)
Used for parameter setting protection, in case of modification of the setted parameter without permission.
7. Phase in valid fixed value (function code P07)
This fixed value is valid only when motor operation current is less than P04, when P07 is less than motor operation current value, and the motor operation current value is less than P04, it means in phase is invalid; when motor operation current is less than P07, it means in phase is valid. (P07 fixed value must be less than P04)
7.5 In power operation
7.5.1 Check before being powered
1. Before connecting the controlling power resource, make sure the AC input voltage is in the rank of permission.
2. Check all connecting screws of all parts are not loose.
3. Confirm there is no short circuit between SCR anode and cathode and the cabinet, and check the SCR resistance value is correct or not. (the following condition is correct: resistance of Cathode and anode is dozens of kilohm, the control electrode and the anode is dozens of kilohm, the control electrode and the Cathode is dozens of ohms )
7.5.2 Test (before turning on motor )
1, Make "W" and "111" of the terminal short circuit (analog start completion signal).
2.Turn down the air switch QF1 in the static phase, at the same time, the out put indicator light on the cabinet door is on, KM1 contactor pull-in, check the main contact with the multimeter, it should be connected.
3, Make the DIP switch of main control panel in test status, as the following diagram shows
: ON
OFF
1
2
3
4
4, Turn down the air switch QF2 in the static phase, WVP controller displays "A05 FA05" or "A06 FA06", and the indicator light on the controller is on; control board L1, L2, l3 periodic cycles, in addition to L5 is off, the other four lights always on. The lights (totally 12) on the driver board are on
5, Press" in phase" button, KM2 pull in, KM1 disconnected. In phase lights on the cabinet door and the the controller are on. Out phase light is off. Inside motor start working. Every lights on the control panel is the same as before in phase. In out phase for several times, KM1, KM2 pull in easily, and no cable wiring.
6, Press out phase button, turn off air switch QF2 and QF1, restore the short circle "W" and "111" on the terminal XT2,
7.5.3 Phase in with load
1, Make DIP switch on the main control panel in the WVP working condition, as the following diagram shows
ON
OFF
1
2
3
4
2, Turn off the air switch QF1 and QF2 in the static phase cabinet, and set the parameters reasonably according to the parameters function diagram
3. After starting the motor, the controller shows the motor running current and power factor, control board L1, L2, l3 periodic cycle, the other five lights are on all the time, the lights on the driver board are shining bright or minor. (If the LED status does not match, you can not enter phase)
4, Press the button to enter phase, the motor current should decrease and the power factor should be increased, if the current increase, should be immediately out phase, turn off the air switch QF2 inside, and exchange TC's 0V and 6V phase on synchronous transformer
5. Adjust compensation transformer voltage and the controller parameter setting value according to the actual effects. (Note: This operation must be carried out under the withdrawal phase state)
Note:
1. Before starting the main motor phase inside air switch (QF1) must be turned off, make the static phase powered, or, the host can not start (pressing starting button is invalid.)
2. Forbid turning off the phase power when the host is still working. Turn off the air switch QF1 in the phase, or cut off the 380V power Otherwise, it will make the main motor stop.
3, When restart the equipment in the condition of fully repair or the static phase is out of work for some time, please check the lights on the control unit in the cabinet are normal or not, then can be put into phase.
4. When in phase, if the stator current changing sharply, should withdraw phase immediately. Find out the reason, repair it and then put into use.
5. Forbid frequently entering phase and withdrawal phase, the repeat operation interval is not less than 1 minute.
6. Forbid pulling out and inserting control interval at will.
7. Overhaul the static phase can not be carried out when the phase is in phase, please withdrawal phase immediately if there is any problem.
8. Strictly observe the boot order of "start first, enter phase secondly" and the stop order of "withdrawal phase first, enter phase second", and shall not operate in reverse order
VIII. Basic maintenance
1) Check if the cooling fan stops running regularly, recede in time and inspect or replace the fan if it stops to avoid burning the thyristor.
2) Inspect the contacts of the two contactors of the advancer timely to prolong the service lifespan of the contactor and to guarantee the safe operation of the advancer and the motor.
3) Sweep and clear away the dust on the advancer timely to avoid that too much dust affects the normal radiation of the thyristor inside the advancer and of the transformer as well as to avoid the normal operation of the control unit. Dusting must be done especially when the advancer is reused after a long time non-use.
IX. Inspection manual
9.1 The maintenance of light current trouble
9.1.1 The meanings that each indicator light presents on the WVP pane are as follows:
the main board
L1, L2, L3, three-phase current direction of the motor stator
L4,+5Vdirection of power supply
L5, direction of heat trouble
L6, direction of phase-open and automatically trouble protection
L7, +15Vdirection of power supply
L8, -15Vdirection of power supply
the drive panel
There are 12 lights on the two drive panel , respectively represent the triggering signal of the 12 thyristors, they are on and shinning lightly on normal condition.
9.1.2 Common troubleshooting
1. All the lights on the control panel are not normal
.a. if some of the lights on the three panels are not on:
Replace IC210 on the main board;
Replace 2004 if does not work.
b. if one or two lights on the three panels are not on:
Check if the panel is inserted well.
Replace 555 chips on two drive panels
c. if all of the lights on the three panels are not on:
Check if the main panel is inserted well.
Check if the star contactor is closed. Check is the constantly open auxiliary contact (W, 111) is connected or not
2. Lights on the control panel are not normal:
Observe that if L1~L3 twinkle normally and roundly, and observe that if L4~L8 are constantly on.
a. replace IC211 chip if some light is roundly on well someone is no of L1~L3, as well as other lights are all on:
If L6 is off and others are all on, replace IC210 chip;
Check the current transformer is normal or not.
b. L1~L3 all don't circle:
Replace IC211 if L4~L8 are all on;
If L6 is not on and others are all on, replace IC210,IC205,IC207 chips
c. L6 is off on the control panel and others are normal:
Replace IC207 chip of the control panel;
Replace IC209 chip of the control panel;
d. Each light on the panel is normal well the one on the SSR is off, and then check:
If the temperature of TM output copper row is too high or not,check the axial fan is normal or not, SCR is breakdown or not
If the temperature is not high, check whether the temperature switch is open and solid state relay is bad
3. Lights on drive panel are not normal.
a. Some of the lights on the drive panel are not on, replace 2004;
b. All of the lights on the drive panel are not on, replace 555
9.2. The inspection of heavy current trouble
When the advancer is in trouble, please observe if the indicator lights on the control panel is normal in normal operating state of the host. If it is normal, please inspect as the process of the inspection of heavy current trouble.
1. The motor can't be started
a, Check if the air switch is closed (it shall be closed). Check if the power supply is normal;
b, Check if KM1 is closed normally.
c, Check if the auxiliary contacts 121, 123 of KM1 are closed and connecting normally.
d, Check the starting equipment and the interlock of other starting device.
2. Press phase-in button to advance; press phase-in releasing button to recede immediately.
a,Check if the insurance FU is good
b,Check if the circuit bundle of KM3 is in good condition and can close normally. It shall be no impermanent short circuit. The contact shall not be ablated or burned;
c,Check if the axial flow fan MF is normal
d,Check if KM4 is in good condition and can close normally. It shall be no short circuit or open circuit. The contact shall not be ablated
e,Check if the contactor of KM2 can close normally; check if it has dither phenomenon (can add 380V AC voltage test alone; but attention must be paid to check if the circuit bundle has short circuit condition) and if the auxiliary contact is burned or felt; check if the constant closed point KA is felt without closing and if the constant closed point KMI is not closed.
3. The host stops after phase-in
a,Make sure the phase sequence of the power supply (or it of the rotor) has not been changed. Please change the phase sequence again if it was changed
b,Make sure the voltage of the power supply ( including the stator power supply of the host and the control power supply) is normal;
c,after stopping the main motor, power off the primary cabinet (that is open the high voltage isolator or open the knife switch of low voltage air switch)
d,Cut off the air switch QF2 in the advancer, and turn the code switch of the main panel to test state. See it in page 13 and then close the air switch QF2
e, Remove the stop interlock wire (125,129,131or 133) which goes to the primary cabinet on the terminal. Check if the auxiliary contacts on KM2 or KM3 have dirty or felt phenomenon.
f, Short circuit the two wires W1, 111 on the terminal;
g, Press phase-in button to observe if the contactor KM2 tingles and check if 125, 129 have closed phenomenon or 131, 133 have open phenomenon. Poor connection of the contact if there are above phenomenon.
h, If KM2 tingles and sounds or can't closed, please remove the coil and replace some of the voltage dividing capacitors in the circuit bundle.
4. Swag in wide range after advance
a,Make sure the phase sequence of the control power supply has not been changed. Please change the phase sequence again if it was changed.
b,Make sure if the power supply of the motor swags in wide range regularly after phase-out. If so, it is affected by load. If not, please conduct inspection as follows.
c,check if the connection wire behind the control panel is loose weld, rosin joint and unwelded;
d,Check if KM2 is closed well. There shall be no sound, otherwise inspect the coil.
e,Check if the axial fan runs normally. If not, please check if KM3, FU are normal and the zero line is connected;
f,Check if the three indicator lights (L1,L2,L3) on the control panel (the one in the middle) are on roundly and regularly. If there is abnormal twinkling, please replace the relevant TA transducer.
g,Close the air switch QF2, and check if the negative electrode and positive electrode resistance is normal by measuring with the multimeter with 200KΩ or MΩ position. Close QF2, check if the trigger voltage of the silicon controlled is normal, if not, and please replace the relative thyristor.
Note:
1. The inspection of the advancer must be done by technicians, casual handling by laymen is not allowed.
2. The trouble shooting of the advancer is: light current inspection before heavy current inspection. That is, firstly check if the control unit (the control panel) is normal, and then check the trouble of heavy current control loop, check if the control unit is normal.
3. If the put-in and take-out of the control panel is needed for inspection, the single phase air- switch QF2 (no affect on the host operation) of the advancer in phase-out state shall be cut off at first. Moreover, overexertion should be avoided during insertion to avoid the damage of the contact pin.
4. Any circuit variety related to the advancer (such as phase sequence of the main loop, phase sequence of the power supply and so on) must be all debugged again.
5. Please contact our company in time in case of any unsettled problem. We will supply you with technology support at any time.
X. Quality assurance
The quality assurance of this product shall be handled according to the following rules and regulations:
1.The maintenance period of this product shall be 12 months after purchase, but should not exceed 15 months after the manufacturing date recorded on the nameplate. However, failures due to the following reasons shall be repaired for compensation even in the maintenance period.
l Problems due to incorrect operation or impermissible repair and reconstruction of one's own-self.
l Problems due to using exceeding the requirements of standard specification.
l Damage due to falling or carrying ferociously after purchasing.
l Aging or failures of the device resulting from using in the circumstances not conforming to the requirements of this manual.
l Failures resulting from earthquake, fire, wind and flood disaster, lightning stroke, abnormal voltage or other natural disasters, or the causes concomitant.
2.You will enjoy the tech support lifetime and paid services whenever and wherever using our product.
l The sales, production and agency of our company across the country shall provide after-sale service.
l If the products fail to operate, our company has the right to assign other persons for maintenance.
3.Matters concerning dissolution of responsibility
l Our company will not undertake the responsibilities resulting or reducing from using this product departing from the regulations of this manual.
l Our company will not be responsible for compensating the losses or affected and subsequent damage of your party due to the failure of the product.
XI. Ordering notice
Please offer the following data to the manufacturer when make an order:
l Motor type,, rated power, stator current, stator voltage, rotor current, rotor voltage, rated power factor cosj, and transformation ratio of current transformer in the motor control cabinet
l The surface color of the cabinet
l We can provide high and low voltage switch cabinet, WYQ series liquid resistance starter according to the requirements of customer
l Please negotiate with our company when you have special requirements.
[Attached] inspection method for the thyristor:
The one lead out from the air duct of the thyristor and was fastened on isolating board by the screws of M4 is the trigger electrode of the thyristor. And that radiator terminal connected with the trigger wire is the negative electrode of the thyristor. The easy method to inspect if the thyristor is good is to measure the resistance of its each electrode. The resistance among each electrode of good thyristor is as follows:
Trigger electrode and negative electrode --dozens of ohms;
Trigger electrode and positive electrode --dozens of kilohm,
Negative electrode and positive electrode --dozens of kilohm
Alamat:
No.1 Wanzhou Road, Xiangyang City, Hubei Province, Xiangyang, Hubei, China
Jenis Usaha:
Produsen/Pabrik
Jangkauan Bisnis:
Listrik & Elektronik, Perlengkapan Industri & Komponen
Produk Utama:
Starter lembut, switchgear, Kabinet Sakelar, Hemat Daya, Distribusi Daya, Switchgear Tegangan Rendah
Pengenalan Perusahaan:
Co., (disebut di seluruh dunia untuk keperluan singkat) adalah perusahaan patungan teknologi yang berspesialisasi dalam R&D, manufaktur dan operasi. Produk kami adalah peralatan hemat energi & pengendali elektromotor, hemat energi & otomatisasi sistem listrik, kabinet saklar tinggi & rendah, dan sistem turn-key, alat berat kontrol angka, dll. mereka secara luas digunakan dalam bahan bangunan, industri kimia, metalurgi, pertambangan, mesin, mesin mobil rumah tangga, perkotaan, tenaga rumah tangga dan seterusnya.
Sejak didirikan pada tahun 2000, seluruh dunia mematuhi konsepsi manajemen tentang "membuat produk merek terkenal, menawarkan layanan merek terkenal, menjadi perusahaan merek terkenal", yang bertujuan menyediakan produk yang unggul dan layanan berkualitas tinggi bagi pelanggan di seluruh dunia. Kita bersikeras tentang kemajuan dan inovasi ilmiah, dan 17 jenis produk kita memenangkan paten nasional. Selama 10 tahun pembangunan, di seluruh dunia merupakan sebuah kelompok terkemuka di bidang listrik dan elektronik China yang memiliki 3 anak perusahaan, lebih dari 600 karyawan, hampir $80 juta penjualan tahunan dan skala perusahaan mencapai angka No. 1 di bidang perdagangan.
Dalam beberapa tahun ke depan, seluruh dunia akan meningkatkan mekanisme manajemen operasi untuk mencapai penjualan tahunan sebesar $150 juta guna mewujudkan cita-cita kami yang "berakar dari China luas, serta aspirasinya bagi seluruh dunia".
Sejak didirikan pada tahun 2000, seluruh dunia mematuhi konsepsi manajemen tentang "membuat produk merek terkenal, menawarkan layanan merek terkenal, menjadi perusahaan merek terkenal", yang bertujuan menyediakan produk yang unggul dan layanan berkualitas tinggi bagi pelanggan di seluruh dunia. Kita bersikeras tentang kemajuan dan inovasi ilmiah, dan 17 jenis produk kita memenangkan paten nasional. Selama 10 tahun pembangunan, di seluruh dunia merupakan sebuah kelompok terkemuka di bidang listrik dan elektronik China yang memiliki 3 anak perusahaan, lebih dari 600 karyawan, hampir $80 juta penjualan tahunan dan skala perusahaan mencapai angka No. 1 di bidang perdagangan.
Dalam beberapa tahun ke depan, seluruh dunia akan meningkatkan mekanisme manajemen operasi untuk mencapai penjualan tahunan sebesar $150 juta guna mewujudkan cita-cita kami yang "berakar dari China luas, serta aspirasinya bagi seluruh dunia".