☆ kesalahan rasio transformer arus dan kalibrasi kapasitas fase. |
|
☆ mengukur sifat magnetik produk semi-diselesaikan inti. |
|
Rentang saat ini | Stabilitas jangka pendek (%/mnt) |
Ketidakpastian Pengukuran (k=2, ppm*RD+ppm*RG)1 |
Tegangan Beban Maksimum(V) | Distorsi (%) |
||
24 jam (23±1) C |
90 hari (23±5) C |
1 tahun (23±5) C |
||||
2 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
5 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
10 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
20 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
50 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
100 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
200 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
500 mA | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
1 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
2 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
5 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
10 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
20 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
50 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
100 A | 0.003 | 20 + 20 | 25 + 20 | 30 + 20 | 1.2 | < 0.2 |
Catatan: 1 RD adalah nilai hasil pengukuran, RG adalah nilai rentang, sama di bawah. |
AC | Rentang | Resolusi | Ketidakpastian Pengukuran (k=2, ppm*RD +ppm*RG) |
||
24 jam (23±1) C |
90 hari (23±5) C |
1 tahun (23±5) C |
|||
ACV/U2 | 20 mV | 10 NV | 40 + 40 | 50 + 40 | 60 + 40 |
50 mV | 10 NV | 20 + 20 | 25 + 20 | 30 + 20 | |
100 mV | 100 NV | 20 + 20 | 25 + 20 | 30 + 20 | |
200 mV | 100 NV | 20 + 20 | 25 + 20 | 30 + 20 | |
500 mV | 100 NV | 20 + 20 | 25 + 20 | 30 + 20 | |
1 V. | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
2 V. | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
5 V. | 1 μV | 20 + 20 | 25 + 20 | 30 + 20 | |
ACI/I2 | 200 μA | 0.1 NA | 20 + 20 | 25 + 20 | 30 + 20 |
500 μA | 0.1 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
1 mA | 1 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
2 mA | 1 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
5 mA | 1 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
10 mA | 10 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
20 mA | 10 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
50 mA | 10 NA | 20 + 20 | 25 + 20 | 30 + 20 | |
100 mA | 100 NA | 20 + 20 | 25 + 20 | 30 + 20 |
Galat Rasio | Kisaran pengukuran | Arus input transformer arus seperti I1 Arus output transformer arus seperti I2 |
Ketidakpastian Pengukuran (k=2) |
0.01% @ - 45 Hz - 65 Hz | |
Kapasitas Fase | Kisaran pengukuran | 0.000 359.999 |
Ketidakpastian Pengukuran (k=2) |
0.001 45 @ 65 Hz Hz |
Parameter terukur | Ketidakpastian Pengukuran (k=2) |
Pengulangan pengukuran |
μi | 1.5% | 4.0% |
μm | 1.0% | 2.0% |
HC | 0.5% | 1.0% |
Br | 0.3% | 1.0% |
BS | 0.3% | 1.0% |
μa | 1.0% | 3.0% |
BM | 0.5% | 1.0% |
HM | 1.0% | 2.0% |
δ | 1.5% | 5.0% |
HC | 1.0% | 3.0% |
Br | 1.0% | 3.0% |
μ' | 1.0% | 3.0% |
μ telah saya buat | 1.0% | 3.0% |
μL | 1.0% | 3.0% |
Catatan: Inti setrika harus diambil magnetnya sebelum pengujian, dan parameter inti setrika harus dimasukkan bila diperlukan. Suhu pengukuran T: (23±5) C. |