Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer, General-Purpose High-Performance Current Vector |
---|---|
Output Type: | tiga fase |
Principle of Work: | V/F Control Transducer |
Switch Mode: | PAM Control |
Main Circuit Type: | Voltage |
Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
Pemasok dengan izin usaha terverifikasi
YCB2000PV | T | 5D5 | G | |
Contoh | Tegangan output | Daya adaptif | Tipe muatan | |
Photovotaic Inverter |
S: Single Phase AC220V T: Tiga fase AC380V |
0D75:0,75KW 1D5:1,5KW HANYA 2 KW 4D0:4,0KW 5D5:5,5KW 7D5:7,5KW 011:11KW 015:15KW .... 110:110KW |
G: Torsi konstan | |
Contoh | YCB2000PV-S0D7G | YCB2000PV-S1D5G | YCB2000PV-S2D2G | YCB2000PV-T2D2G | YCB2000PV-T40G | ||
Data input | |||||||
Sumber PV | |||||||
Tegangan input maks(VOC)[V] | 400 | 750 | |||||
Tegangan input min, pada mpp[V] | 180 | 350 | |||||
Tegangan yang direkomendasikan,pada mpp | 280VDC VDC | 500 VDC. 600 VDC | |||||
Input amps yang disarankan,pada mpp[A] | 4.7 | 7.3 | 10.4 | 6.2 11.3 | |||
Daya maks yang disarankan pada mpp[kW] | 1.5 | 3 | 4.4 | 11 15 | |||
Generator AC alternatif | |||||||
Tegangan input | 220/230/240VAV(±15%),Fase Tunggal | 380VAV(±15%) tiga Fase | |||||
MAX amps(RMS)[A] | 8.2 | 14.0 | 23 | 5.8 | 10.0 | ||
Daya dan kemampuan va [kVA] | 2.0 | 3.1 | 5.1 | 5.0 | 6.6 | ||
Data output | |||||||
Daya output tetapan[kW] | 0.75 | 1.5 | 2.2 | 2.2 | 4 | ||
Tegangan output tetapan | 220/230/240VAC,Fase Tunggal | 380VAC,tiga Fase | |||||
MAX amps(RMS)[A] | 4.5 | 7.0 | 10 | 5.0 | 9.0 | ||
Frekuensi output | 0-50Hz/60Hz | ||||||
Parameter konfigurasi sistem pompa | |||||||
Daya panel surya yang direkomendasikan (KW) | 1.0-1.2 | 2.0-2.4 | 3.0-3.5 | 3.0-3.5 | 5.2-6.4 | ||
Koneksi panel surya | TAMBAH PENUKAR ASCII KE TAMBAH-PENUKAR ASCII | TAMBAH PENUKAR ASCII KE TAMBAH BINTIK 250W PADA TAMBAH BINTIK | TAMBAH PENUKAR ASCII PENUKAR ASCII PADA TAMBAH BINTIK 25 0W | TAMBAH PENUKAR ASCII [ TAMBAH BINTIK-BINTIK 250W ) PADA TAMBAH BINTIK-BINTIK | TAMBAH PENUKAR ASCII PENUKAR ASCII ASCII PADA TAMBAH BINTIK-BINTIK | ||
Pompa yang berlaku (kW) | 0.37-0.55 | 0.75-1.1 | 1.5 | 1.5 | 2.2-3 | ||
Tegangan motor pompa (V) | 3 fase 220 | 3 fase 220 | 3 fase 220 | 3 fase 380 | 3 fase 380 |
Contoh | YCB2000PV-T5D5G | YCB2000PV-T7D5G | YCB2000PV-T011G | YCB2000PV-T015G | YCB2000PV-T018G | |||
Data input | ||||||||
Sumber PV | ||||||||
Tegangan input maks(VOC)[V] | 750 | |||||||
Tegangan input min, pada mpp[V] | 350 | |||||||
Tegangan yang direkomendasikan,pada mpp | 500 VDC. 600 VDC | |||||||
Input amps yang disarankan,pada mpp[A] | 16.2 | 21.2 | 31.2 | 39.6 | 46.8 | |||
Daya maks yang disarankan pada mpp[kW] | 22 | 30 | 22 | 30 | 37 | |||
Generator AC alternatif | ||||||||
Tegangan input | 380VAV(±15%) , tiga Fase | |||||||
MAX amps(RMS)[A] | 15 | 20 | 26.0 | 35.0 | 46.0 | |||
Daya dan kemampuan va [kVA] | 9.0 | 13.0 | 17.0 | 23.0 | 25 | |||
Data output | ||||||||
Daya output tetapan[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 | |||
Tegangan output tetapan | 380VAC,tiga Fase | |||||||
MAX amps(RMS)[A] | 13 | 17 | 25.0 | 32.0 | 37 | |||
Frekuensi output | 0-50Hz/60Hz | |||||||
Parameter konfigurasi sistem pompa | ||||||||
Daya panel surya yang direkomendasikan (KW) | 7.2-8.8 | 9.8-12 | 14.3-17.6 | 19.5-24 | 24-29.6 | |||
Koneksi panel surya | TAMBAH PENUKAR ASCII DENGAN TAMBAH BINTIK RP 40P 2 seri 20 paralel |
TAMBAH PENUKAR ASCII PADA TAMBAH BINTIK 250W PADA TAMBAH BINTIK 2 seri 24 paralel |
TAMBAH BINTIK PADA 250W 60P 30 V. 3 seri 20 paralel |
TAMBAH ASCII PADA TAMBAH BINTIK-BINTIK BINTIK 25 W 4 seri 21 paralel |
TAMBAH TAMBAH PENUKAR ASCII KE TAMBAH PENUKAR ASCII SEBESAR RP 250W 5 seri 20 paralel |
|||
Pompa yang berlaku (kW) | 3.7-4 | 4.5-5.5 | 7.5-9.2 | 11-13 | 15 | |||
Tegangan motor pompa (V) | 3 fase 380 | 3 fase 380 | 3 fase 380 | 3 fase 380 | 3 fase 380 |
Contoh | YCB2000PV-T022G | YCB2000PV-T030G | YCB2000PV-T037G | YCB2000PV-T045G | |||||
Data input | |||||||||
Sumber PV | |||||||||
Tegangan input maks(VOC)[V] | 750 | ||||||||
Tegangan input min, pada mpp[V] | 350 | ||||||||
Tegangan yang direkomendasikan,pada mpp | 500 VDC. 600 VDC | ||||||||
Input amps yang disarankan,pada mpp[A] | 56.0 | 74.0 | 94.0 | 113 | |||||
Daya maks yang disarankan pada mpp[kW] | 44 | 60 | 74 | 90 | |||||
Generator AC alternatif | |||||||||
Tegangan input | 380VAV(±15%), tiga Fase | ||||||||
MAX amps(RMS)[A] | 62.0 | 76.0 | 76.0 | 90.0 | |||||
Daya dan kemampuan va [kVA] | 30.0 | 41.0 | 50.0 | 59.2 | |||||
Data output | |||||||||
Daya output tetapan[kW] | 22 | 30 | 37 | 45 | |||||
Tegangan output tetapan | 380VAC,tiga Fase | ||||||||
MAX amps(RMS)[A] | 45 | 60 | 75 | 90 | |||||
Frekuensi output | 0-50Hz/60Hz | ||||||||
Parameter konfigurasi sistem pompa | |||||||||
Daya panel surya yang direkomendasikan (KW) | 28.6-35.2 | 39-48 | 48.1-59.2 | 58.5-72 | |||||
Koneksi panel surya | TAMBAH PENUKAR ASCII 120P PADA TAMBAH BINTIK 30 V. 6 seri 20 paralel |
TAMBAH PENUKAR ASCII KE TAMBAH-TAMBAH PADA TAMBAH BINTIK 10 seri 20 paralel |
TAMBAH TAMBAH PENUKAR ASCII KE TAMBAH KAMAR 12 seri 22 paralel |
TAMBAH ASCII PADA TAMBAH BINTIK-BINTIK BINTIK 25 W 4 seri 21 paralel |
|||||
Pompa yang berlaku (kW) | 18.5 | 22-26 | 30 | 37-40 | |||||
Tegangan motor pompa (V) | 3 fase 380 | 3 fase 380 | 3 fase 380 | 3 fase 380 |
Contoh | YCB2000PV-T055G | YCB2000PV-T075G | YCB2000PV-T090G | YCB2000PV-T110G | ||||
Data input | ||||||||
Sumber PV | ||||||||
Tegangan input maks(VOC)[V] | 750 | |||||||
Tegangan input min, pada mpp[V] | 350 | |||||||
Tegangan yang direkomendasikan,pada mpp | 500 VDC. 600 VDC | |||||||
Input amps yang disarankan,pada mpp[A] | 105 | 140 | 160 | 210 | ||||
Daya maks yang disarankan pada mpp[kW] | 55 | 75 | 90 | 110 | ||||
Generator AC alternatif | ||||||||
Tegangan input | 380VAV(±15%), tiga Fase | |||||||
MAX amps(RMS)[A] | 113 | 157 | 180 | 214 | ||||
Daya dan kemampuan va [kVA] | 85 | 114 | 134 | |||||
160 | ||||||||
Data output | ||||||||
Daya output tetapan[kW] | 55 | 75 | 93 | 110 | ||||
Tegangan output tetapan | 380VAC,tiga Fase | |||||||
MAX amps(RMS)[A] | 112 | 150 | 176 | 210 | ||||
Frekuensi output | 0-50Hz/60Hz | |||||||
Parameter konfigurasi sistem pompa | ||||||||
Daya panel surya yang direkomendasikan (KW) | 53-57 | 73-80 | 87-95 | 98-115 | ||||
Koneksi panel surya | 400W*147P*30V 21seri 7 paralel |
400W*200P*30V 10 seri 20 paralel |
400W*240P*30V 12 seri 20 paralel |
400W*280P*30V 4 seri 20 paralel |
||||
Pompa yang berlaku (kW) | 55 | 75 | 90 | 110 | ||||
Tegangan motor pompa (V) | 3PH 380V | |||||||
Contoh | Ukuran | W(mm) | H(mm) | D(mm) | A(mm) | B(mm) | Pemasangan Apertur |
||||||||||||||||
YCB2000PV-S0D7G | 125 | 185 | 163 | 115 | 175 | 4 | |||||||||||||||||
YCB2000PV-S1D5G | |||||||||||||||||||||||
YCB2000PV-S2D2G | |||||||||||||||||||||||
YCB2000PV-T0D7G | |||||||||||||||||||||||
YCB2000PV-T1D5G | |||||||||||||||||||||||
YCB2000PV-T2D2G | |||||||||||||||||||||||
YCB2000PV-T30G | 150 | 246 | 179 | 136 | 230 | 4 | |||||||||||||||||
YCB2000PV-T40G | |||||||||||||||||||||||
YCB2000PV-T5D5G | |||||||||||||||||||||||
YCB2000PV-T7D5G | |||||||||||||||||||||||
YCB2000PV-T011G | 218 | 320 | 218 | 201 | 306 | 5 | |||||||||||||||||
YCB2000PV-T015G | |||||||||||||||||||||||
YCB2000PV-T018G | |||||||||||||||||||||||
YCB2000PV-T022G | 235 | 420 | 210 | 150 | 404 | 5 | |||||||||||||||||
YCB2000PV-T030G | 270 | 460 | 220 | 195 | 433 | 6 | |||||||||||||||||
YCB2000PV-T037G | |||||||||||||||||||||||
YCB2000PV-T045G | 320 | 565 | 275 | 240 | 537 | 6 | |||||||||||||||||
YCB2000PV-T055G | |||||||||||||||||||||||
YCB2000PV-T075G | 380 | 670 | 272 | 274 | 640 | 8 | |||||||||||||||||
YCB2000PV-T090G | |||||||||||||||||||||||
YCB2000PV-T110G |