• Aswich Sakelar Load Disconnect Isolasi 1500V
  • Aswich Sakelar Load Disconnect Isolasi 1500V
  • Aswich Sakelar Load Disconnect Isolasi 1500V
  • Aswich Sakelar Load Disconnect Isolasi 1500V
  • Aswich Sakelar Load Disconnect Isolasi 1500V
  • Aswich Sakelar Load Disconnect Isolasi 1500V
Favorit

Aswich Sakelar Load Disconnect Isolasi 1500V

Type: High-voltage
Installation: Indoor High-voltage
Operation: Electric
Movement Mode: Horizontal Rotary Type
Number of Poles: 2p,3p,4p
Structure of Operating: Electric

Hubungi Pemasok

Tur Virtual 360°

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik

Informasi dasar.

Tidak. Model.
EHD
Certification
CE, SAA
Brand
Aswich
ui tegangan
1000v/1500v
saat ini
315A
Paket Transportasi
by Sea/Air
Spesifikasi
box
Merek Dagang
Aswich
Asal
China
Kode HS
853650
Kapasitas Produksi
1000000PC/Year

Deskripsi Produk

The produced energy can be used to power a local load (off-grid systems) or it can be fed into the public power-grid (grid-connected systems). As the PV generator output is direct DC and most loads and public grids generally accept only AC, PV inverters are used to perform the necessary DC-AC conversion. As the current and voltage output of a PV generator are not constant, the inverter must also adjust to the changes at its input circuit so that the maximum possible power is drawn from the generator. By way of an example, the amount of light available naturally contributes to the PV cells' current output, whereas the voltage output is inversely affected by the cell temperature. Between the PV panels and the AC grid are the so-called balance-of-system (BOS) components. These include the inverter, the interconnecting cables, wires, over-current and surge protection, earthing equipment and a means for switching and disconnecting different parts of the circuit. For example, the international standard IEC 60364-7-712 requires a means for disconnecting the inverter from both sides. Moreover, the standard specifically demands a switch disconnector to be provided on the DC side of the PV inverter. This allows the disconnection and reliable isolation of the inverter from all DC sources. Additional switch equipment can be used for disconnecting parts of the PV array, for system earthing or for switching possible energy-storage circuits.

Advantages

High breaking performance

A glass fibre reinforced polyester break chamber with an arc extinguishing system provides a patented safety disconnection system offering rapid extinguishing of the electric arc up to 1500 VDC and current interruption up to 800 A.

Remotely operated product

ASWICH PV are intended for use in photovoltaic installations and solar inverters. They can be remotely controlled via volt-free contacts, from either an external automatic controller or a switch.

Manual emergency operation

In addition to its motorised operation, the ASWICH PV also includes a manual operation facility, enabling the switch position to be changed directly on the device if required.



Detail

Aswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect Switch



About us


Aswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect SwitchAswich 1500V Isolation Load Disconnect Switch

Aswich 1500V Isolation Load Disconnect Switch

Aswich 1500V Isolation Load Disconnect Switch

Kirim permintaan informasi Anda langsung ke penyedia ini

*Dari:
*Untuk:
*Pesan:

Masukkan antara 20 dan 4000 karakter.

Ini bukan yang Anda cari? Posting Permintaan Sourcing SEKARANG

Temukan Produk Serupa Berdasarkan Kategori

Anda Mungkin Juga Menyukai

Hubungi Pemasok

Tur Virtual 360°

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik
Modal Terdaftar
100000 RMB
Area Pabrik
>2000 meter persegi