Tipe | CJX2N-09 | CJX2N-12 | CJX2N-18 | CJX2N-25 | CJX2N-32 | CJX2N-38 | CJX2N-40 | |
Arus kerja tetapan (A) AC-3 Ue≤440V |
9 | 12 | 18 | 25 | 32 | 38 | 40 | |
Arus dengar tetapan ith (A) | 25 | 25 | 32 | 40 | 50 | 50 | 60 | |
UI voltase isolasi tetapan (V) | 690 | 690 | 690 | 690 | 690 | 690 | 1000 | |
Tegangan kerja tetapan (V) Maks. | 690 | 690 | 690 | 690 | 690 | 690 | 1000 | |
Daya operasional tetapan pada AC-3 PE (KW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 9 | 11 |
380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 18.5 | |
415/440V | 4 | 5.5 | 9 | 11 | 15 | 18.5 | 22 | |
500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 18.5 | 22 | |
660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 18.5 | 30 | |
Daya operasional tetapan AC-4 PE (KW) | 220/230V | 1.5 | 1.5 | 2.2 | 3 | 4 | 4 | 4 |
380/400V | 2.2 | 3.7 | 4 | 5.5 | 7.5 | 7.5 | 9 | |
415/440V | 2.2 | 3 | 3.7 | 5.5 | 7.5 | 7.5 | 9/11 | |
500V | 3 | 4 | 5.5 | 7.5 | 9 | 9 | 11 | |
660/690V | 4 | 5.5 | 7.5 | 10 | 11 | 11 | 15 | |
Frekuensi pengoperasian (I/h) | 1200 | 1200 | 1200 | 1200 | 1000 | 1000 | 1000 | |
Ketahanan Listrik (x104) | AC-3 | 100 | 100 | 100 | 100 | 80 | 80 | 80 |
AC-4 | 20 | 20 | 20 | 20 | 20 | 20 | 15 | |
Ketahanan Mekanis (x106) | 15 | 15 | 15 | 15 | 15 | 15 | 6 | |
Rentang voltase pengoperasian coil | Tegangan dekat:(0.85. 1.1)kita memiliki voltase terbuka:(20% 75%)US | |||||||
Konsumsi daya coil (VA) | Mengurangi | 7 | 7 | 7 | 7 | 7 | 7 | 20 |
Memulai | 70 | 70 | 70 | 70 | 70 | 70 | 200 | |
Tegangan isolasi tetapan Kontak ixiitie (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Arus termal konvensional kontak ixiiiputih (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Spesifikasi kontak lebih cepat | AC-15:360VA DC-13:33W |
Tipe | CJX2N-50 | CJX2N-65 | CJX2N-80 | CJX2N-95 | CJX2N-115 | CJX2N-150 | |
Arus kerja tetapan (A) AC-3 Ue≤440V |
50 | 65 | 80 | 95 | 115 | 150 | |
Arus dengar tetapan ith (A) | 80 | 80 | 125 | 125 | 200 | 200 | |
UI voltase isolasi tetapan (V) | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Tegangan kerja tetapan (V) Maks. | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | |
Daya operasional tetapan pada AC-3 PE (KW) | 220/230V | 15 | 18.5 | 22 | 25 | 30 | 40 |
380/400V | 22 | 30 | 37 | 45 | 55 | 75 | |
415/440V | 25/30 | 37 | 45 | 45 | 59 | 80 | |
500V | 30 | 37 | 55 | 55 | 75 | 90 | |
660/690V | 33 | 37 | 45 | 45 | 80 | 100 | |
Daya operasional tetapan AC-4 PE (KW) | 220/230V | 5.5 | 7.5 | 7.5 | 9 | 9 | 11 |
380/400V | 11 | 11 | 15 | 15 | 18.5 | 22 | |
415/440V | 11 | 11/15 | 15 | 15 | 18.5 | 22 | |
500V | 15 | 18.5 | 22 | 22 | 30 | 37 | |
660/690V | 18.5 | 22 | 25 | 25 | 30 | 45 | |
Frekuensi pengoperasian (I/h) | 1000 | 1000 | 750 | 750 | 750 | 750 | |
Ketahanan Listrik (x104) | AC-3 | 60 | 60 | 60 | 60 | 60 | 60 |
AC-4 | 15 | 15 | 15 | 15 | 15 | 15 | |
Ketahanan Mekanis (x106) | 6 | 6 | 4 | 4 | 4 | 4 | |
Rentang voltase pengoperasian coil | Tegangan dekat:(0.85. 1.1)kita memiliki voltase terbuka:(20% 75%)US | ||||||
Konsumsi daya coil (VA) | Mengurangi | 20 | 20 | 20 | 20 | 22 | 22 |
Memulai | 200 | 200 | 200 | 200 | 300 | 300 | |
Tegangan isolasi tetapan Kontak ixiitie (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 |
Arus termal konvensional kontak ixiiiputih (A) | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Spesifikasi kontak lebih cepat | AC-15:360VA DC-13:33W |
Volt | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 | 500 | 660 |
50 Hz | B5 | D5 | E5 | F5 | E5 | F5 | U5 | P5 | V5 | N5 | R5 | S5 | Y5 |
60 Hz | B6 | D6 | E6 | F6 | E6 | F6 | U6 | P6 | - | - | R6 | ||
50/60Hz | B7 | D7 | E7 | F7 | E7 | F7 | U7 | P7 | V7 | N7 | R7 |