After-sales Service: | Yes |
---|---|
Warranty: | Yes |
Sifat Aliran Sumber: | Inverter Aktif |
Fase: | Tiga |
Daya Output: | 501 - 1000W |
Sertifikasi: | CE, ISO9001 |
Pemasok dengan izin usaha terverifikasi
GROWATT SPH 4000- SPH 10000TL3 BH-UP
|
||||||
Spesifikasi
|
SPH4000TL3 BH-UP
|
SPH5000TL3 BH-UP
|
SPH6000TL3 BH-UP
|
SPH7000L3 BH-UP
|
SPH8000TL3 BH-UP
|
SPH10000TL3 BH-UP
|
Data input (PV)
|
||||||
Daya PV maks (STC)
|
600 0W
|
7500W
|
9000W
|
10500W
|
1200 0W
|
1500 0W
|
Tegangan DC maks
|
1000V
|
|||||
Tegangan start
|
120V
|
|||||
Kisaran Tegangan MPP
|
120V-1000V/600V
|
|||||
Jumlah pelacak MPP
|
2
|
|||||
No. String PV per pelacak MPP
|
1
|
|||||
Arus input maks. Per pelacak MPP
|
13,5A
|
|||||
Arus hubung-singkat maks per pelacak MPP
|
16,9A
|
|||||
Data output(AC)
|
||||||
Daya nominal AC
|
4000W
|
5000W
|
600 0W
|
700 0W
|
800 0W
|
10000W
|
Maks. Daya nyata AC
|
4000VA
|
5000 VA
|
6000VA
|
7000VA
|
8000VA
|
10000VA
|
Tegangan AC nominal (kisaran*)
|
230V/400V (310-476V)
|
|||||
Frekuensi kisi AC (rentang)
|
50Hz/60Hz (45Hz-55Hz/55Hz-65Hz)
|
|||||
Arus output maks
|
6,1A
|
7,6A
|
9,1A
|
10,6A
|
12,1A
|
15,2A
|
Faktor daya yang dapat disesuaikan
|
0,8memimpin... 0,8tertinggal
|
|||||
THDi
|
<3%
|
|||||
Tipe koneksi kisi AC
|
3W+N+PE
|
|||||
Data baterai (DC)
|
||||||
Rentang voltase baterai
|
100
|
|||||
Pengisian dan pengosongan arus maks
|
25A
|
|||||
Pengisian daya kontinu dan pengosongan arus
|
4000W
|
5000W
|
600 0W
|
700 0W
|
800 0W
|
10000W
|
Jenis baterai
|
Baterai lithium
|
|||||
Daya cadangan(AC)
|
||||||
Maks. Daya output AC
|
4000W
|
5000W
|
600 0W
|
700 0W
|
800 0W
|
10000W
|
Maks. Daya nyata AC
|
4000VA
|
5000 VA
|
6000VA
|
7000VA
|
8000VA
|
10000VA
|
Arus output maks
|
6,1A
|
7,6A
|
9,1A
|
10,6A
|
12,1A
|
15,2A
|
Tegangan output AC nominal
|
230V/400V
|
|||||
Frekuensi output AC nominal
|
50/60HZ
|
|||||
THDv
|
<3%
|
|||||
Beralih waktu
|
<10ms
|
|||||
Efisiensi
|
||||||
Efisiensi Maks.
|
97.6%
|
97.8%
|
98.0%
|
98.2%
|
98.2%
|
98.2%
|
Efisiensi Eropa
|
97.0%
|
97.2%
|
97.3%
|
97.4%
|
97.4%
|
97.5%
|
Perangkat perlindungan
|
||||||
Sakelar DC
|
Ya
|
|||||
Pelindung polaritas terbalik DC
|
Ya
|
|||||
Perlindungan lonjakan daya AC/DC
|
Tipe II
|
|||||
Perlindungan baterai mundur
|
Ya
|
|||||
Perlindungan hubung-singkat AC
|
Ya
|
|||||
Pemantauan kerusakan ground
|
Ya
|
|||||
Pemantauan kisi
|
Ya
|
|||||
Perlindungan anti-pendaratan
|
Ya
|
|||||
Unit pemantauan arus residu
|
Ya
|
|||||
Pemantauan resistan isolasi
|
Ya
|
Pemasok dengan izin usaha terverifikasi