Type: | Fiber Transceiver |
---|---|
Wiring Devices: | Fiber Switch, Router, Network Cark, SDH, Server |
Certification: | ISO, RoHS |
Condition: | New |
tarif: | 1,25 gbps |
antarmuka: | lc |
Pemasok dengan izin usaha terverifikasi
Parameter | Simbol | Min | Maks. | Satuan |
Tegangan Suplai | Vcc | -0,5 | 4.5 | V |
Suhu Penyimpanan | TS | -40 | +85 | SBP |
Kelembapan Pengoperasian | - | 5 | 85 | % |
Parameter | Simbol | Min | Tipikal | Maks. | Satuan | |
Suhu kotak Pengoperasian | Standar | TC | 0 | SBP | ||
Diperpanjang | -20 | SBP | ||||
Industri | -40 | +85 | SBP | |||
Tegangan Catu Daya | Vcc | 3.135 | 3.30 | 3.465 | V | |
Arus Catu Daya | ICC | 300 | MA | |||
Laju Data | 155 | Mbps |
Parameter | Simbol | Min | Tipikal | Maks. | Satuan | Catatan | ||
Transmitter (Transmiter) | ||||||||
Garis Panjang Gelombang Tengah | λc | 1530 | 1550 | 1570 | mil laut | |||
Lebar Spektral (-20dB) | Δλ | 1 | mil laut | |||||
Rasio penekanan Mode Samping | SMSR | 30 | - | - | DB | |||
Daya Output Rata-rata | Pout | -5 | +1 | DBm | 1 | |||
Rasio Pemupusan | ER | 9.0 | DB | |||||
Diferensial Ayun Input Data | VIN | 180 | 1200 | MV | 2 | |||
Impedansi Diferensial Input | ZIN | 90 | 100 | 110 | Ω | |||
TX Disable (Nonaktifkan TX) | Nonaktifkan | 2.0 | Vcc | V | ||||
Aktifkan | 0 | 0.8 | V | |||||
Kerusakan TX | Kerusakan | 2.0 | Vcc | V | ||||
Normal | 0 | 0.8 | V | |||||
Penerima | ||||||||
Garis Panjang Gelombang Tengah | λc | 1260 | 1610 | mil laut | ||||
Sensitivitas Penerima | -33 | DBm | 3 | |||||
Penerima Beban Berlebih | -8 | DBm | 3 | |||||
Los De-MARTE | LOSD | -34 | DBm | |||||
Los harus ada | LOSA | -45 | DBm | |||||
LOS Hysteresis (Histeresis) | 0.5 | 4 | DB | |||||
Diferensial Ayun Data | Vout | 600 | 800 | 1000 | MV | 4 | ||
LOS | Tinggi | 2.0 | Vcc | V | ||||
Rendah | 0.8 | V | ||||||
Parameter | Simbol | Min | Tipikal | Maks. | Satuan |
Penonaktifan TX menolak waktu | t_on | 1 | ms | ||
Waktu menyatakan Penonaktifan TX | t_off | 10 | µs | ||
Waktu untuk melakukan inisialisasi, termasuk Reset kerusakan Tx | t_init | 300 | ms | ||
Waktu menyatakan kerusakan TX | t_fault | 100 | µs | ||
TX Disable to Reset (Nonaktifkan TX untuk Reset) | t_reset | 10 | µs | ||
Waktu yang ditentukan OLEH LOS | t_loss_on | 100 | µs | ||
Waktu Los De-menegaskan | t_loss_off | 100 | µs | ||
Laju jam ID Serial | f_serial_clock | 100 | 400 | KHz | |
MOD_DEF (0:2)-Tinggi | VH | 2 | Vcc | V | |
MOD_DEF (0:2)-Rendah | VL | 0.8 | V |
Parameter | Rentang | Satuan | Akurasi | Kalibrasi |
Suhu | 0 hingga +70 | SBP | ±3 C | Internal |
-20 hingga +80 | ||||
-40 hingga +85 | ||||
Tegangan | 3.0 hingga 3.6 | V | ±3% | Internal |
Arus bias | 0 hingga 100 | MA | ±10% | Internal |
Daya Tx | -5 hingga +1 | DBm | ±3dB | Internal |
Rx Power | -33 hingga -6 | DBm | ±3dB | Internal |
Pin | Nama sinyal | Deskripsi | Urutan colokan. | Catatan |
1 | VEET | Ground Pemancar | 1 | |
2 | KESALAHAN TX | Indikasi kerusakan transmiter | 3 | Catatan 1 |
3 | TX NONAKTIF | Transmitter Disable (Penonaktifan Pemancar) | 3 | Catatan 2 |
4 | SDA | Sinyal Data Seri SDA | 3 | |
5 | SCL | Sinyal SCL Serial Clock | 3 | |
6 | MOD_ABS | Modul tidak ada. Terhubung ke ground di dalam modul | 3 | |
7 | RS0 | Tidak tersambung | 3 | |
8 | LOS | Sinyal hilang | 3 | Catatan 3 |
9 | VEER | Ground receiver | 1 | |
10 | VEER | Ground receiver | 1 | |
11 | VEER | Ground receiver | 1 | |
12 | RD- | INV. Data yang diterima | 3 | Catatan 4 |
13 | RD+ | Data yang diterima | 3 | Catatan 4 |
14 | VEER | Ground receiver | 1 | |
15 | VCCR | Catu Daya Penerima | 2 | |
16 | VCCT | Catu Daya Pemancar | 2 | |
17 | VEET | Ground Pemancar | 1 | |
18 | TD+ | Transmit Data in (kirimkan Data dalam) | 3 | Catatan 5 |
19 | TD- | INV. Transmit Data in (kirimkan Data dalam) | 3 | Catatan 5 |
20 | VEET | Ground Pemancar | 1 |
Pemasok dengan izin usaha terverifikasi