Usage: | Telephone, Computer, Workstation, Server, Mobile phone, Data Center |
---|---|
Type: | Both Wired and Wireless |
Support Network: | Ethernet, GPRS, Data, Voice |
Information content: | Data, Voice, Message |
Certification: | CE, ISO, RoHS, FCC |
Condition: | New |
Pemasok dengan izin usaha terverifikasi
Parameter | Simbol | Min. | Tip. | Maks. | Satuan | Catatan |
Suhu Penyimpanan | TS | -40 | - | 85 | ||
Kelembapan relatif | KANAN | 5 | - | 95 | % | |
Tegangan Catu Daya | VCC | -0,3 | - | 4 | V | |
Tegangan Input sinyal | Vcc-0.3 | - | Vcc+0.3 | V |
Parameter | Simbol | Min. | Tip. | Maks. | Satuan | Catatan |
Suhu Pengoperasian Kasus | Kasus | 0 | - | 70 | Tanpa aliran udara | |
Tegangan Catu Daya | VCC | 3.14 | 3.3 | 3.47 | V | |
Arus Catu Daya | ICC | - | 450 | MA | ||
Laju Data | BR | 10.3125 | Gbps | |||
Jarak Transmisi | TD | - | 10 | km | ||
Serat yang disambungkan | Serat mode tunggal | 9/125um SMF |
Parameter | Simbol | Min | Tip | Maks. | Satuan | CATATAN |
Transmitter (Transmiter) | ||||||
Pilihan Output. Daya | POUT | -6 | -0,5 | DBm | 1 | |
Gelombang Optik | λ | 1260 | 1310 | 1355 | mil laut | |
Lebar Spektral (-20dB) | σ | 1 | mil laut | |||
Rasio optical upport | ER | 3.5 | DB | |||
Masker mata Output | Sesuai dengan IEEE 802.3ae | |||||
Penerima | ||||||
Sensitivitas RX | RSENS | 14,4 | DBm | 2 | ||
Daya Saturasi Input (Beban Berlebih) | Sab | 0.5 | DBm | |||
Rentang panjang gelombang | λC | 1270 | 1610 | mil laut | ||
Los De -menyatakan | LOSD | 17 | DBm | |||
Los harus ada | LOSA | 30 | DBm | |||
LOS Hysteresis (Histeresis) | 0.5 | 1.0 | DB |
Parameter | Simbol | Min | Tip | Maks. | Satuan | CATATAN |
Tegangan Suplai | Vcc | 3.14 | 3.3 | 3.46 | V | |
Arus suplai | ICC | 450 | MA | |||
Transmitter (Transmiter) | ||||||
Impedansi diferensial input | Rin | 100 | Ω | 1 | ||
Ayunan input data satu kali diakhiri | Vin,pp | 180 | 700 | MV | ||
Mentransmisikan Tegangan Non Aktif | VD | Vcc-1.3 | Vcc | V | ||
Mentransmisikan Aktifkan Tegangan | VEN | VEE | VEE+ 0.8 | V | 2 | |
Waktu menyatakan Penonaktifan Transmisi | 10 | as | ||||
Penerima | ||||||
Ayunan output data diferensial | Vout, pp | 300 | 850 | MV | 3 | |
Waktu kenaikan output data | tr | 28 | ps | 4 | ||
Waktu penurunan output data | tf | 28 | ps | 4 | ||
Kerusakan LOS | Kesalahan VLOS | Vcc-1.3 | VccHOST | V | 5 | |
LOS Normal | VLOS Norm (norma VLOS) | VEE | VEE+0.8 | V | 5 | |
Penolakan Catu Daya | PSR | 100 | MVpp | 6 |
Pin | Simbol | Nama/Deskripsi | CATATAN |
1 | VEET | Ground Transmitter (Umum dengan Ground Penerima) | 1 |
2 | TFAULT | Transmitter Fault (kerusakan Transmiter). | 2 |
3 | TDIS | Transmitter Disable (Penonaktifan Pemancar). Output laser dinonaktifkan pada tinggi atau terbuka. | 3 |
4 | SDA | Baris Data Antarmuka Seri 2-kabel | 4 |
5 | SCL | Baris jam Antarmuka Serial 2-kabel | 4 |
6 | MOD_ABS | Modul tidak ada. Terhubung ke ground di dalam modul | 4 |
7 | RS0 | Tarif Pilih 0 | 5 |
8 | LOS | Indikasi sinyal hilang. Logika 0 mengindikasikan operasi normal. | 6 |
9 | RS1 | Tidak diperlukan koneksi | 1 |
10 | VEER | Ground Penerima (biasa dengan Transmitter Ground/Ground Transmiter) | 1 |
11 | VEER | Ground Penerima (biasa dengan Transmitter Ground/Ground Transmiter) | 1 |
12 | RD- | Penerima MENGELUARKAN DATA terbalik. AC tersambung | |
13 | RD+ | Data keluar tanpa inversi penerima. AC tersambung | |
14 | VEER | Ground Penerima (biasa dengan Transmitter Ground/Ground Transmiter) | 1 |
15 | VCCR | Catu Daya Penerima | |
16 | VCCT | Catu Daya Pemancar | |
17 | VEET | Ground Transmitter (Umum dengan Ground Penerima) | 1 |
18 | TD+ | Transmitter dengan DATA tidak terbalik di. AC tersambung. | |
19 | TD- | Transmiter DATA pendiam. AC tersambung. | |
20 | VEET | Ground Transmitter (Umum dengan Ground Penerima) | 1 |
Pemasok dengan izin usaha terverifikasi