Output Type: | Single |
---|---|
Warranty: | 2 Years |
Output Power: | 301 - 400W |
Input Voltage: | 110V/220V |
Connection Mode: | Series Switching Power Supply |
Starting Mode: | Self-excited Switching Power Supply |
Pemasok dengan izin usaha terverifikasi
SPESIFIKASI | ||||||||||||||
OUTPUT | ||||||||||||||
Contoh | LRS-350-3.3 | LRS-350-5 | LRS-350-12 | LRS-350-15 | LRS-350-24 | LRS-350-36 | LRS-350-48 | |||||||
Tegangan DC | 3.3V | 5V | 12 V. | 15V | 24V | 36V | 48V | |||||||
Arus tetapan | 60A | 60A | 29A | 23,2A | 14,6A | 9,7A | 7,3A | |||||||
Rentang saat ini | 0 | 0 | 0 MASUK 29A | 0 23,2A | 0 | 0 | 0. 7,3A | |||||||
Daya Tetapan | 198W | 300W | 348W | 348W | 350.4W | 349.2 2W | 350.4W | |||||||
Riak & Derau | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |||||||
Penyesuaian Tegangan. Rentang | 2.97 | 4.5 - 5,5V | 10 | 13.5 V | 21.6 "28,8V" | 32.4 | 43.2 | |||||||
Toleransi tegangan | ±4.0% | ±3.0% | ±1.5% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |||||||
Regulasi Jalur | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||||
Load Regulation (Muat Peraturan) | ±2.5% | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||||||
Pengaturan, waktu naik | 1300ms, 50ms/230VAC 1300ms, 50ms/115VAC pada beban penuh | |||||||||||||
Waktu tunggu | 16ms/230VAC 12ms/115VAC pada beban penuh | |||||||||||||
Kisaran Tegangan | 90 - 22VAC / 180 - 264VAC dipilih oleh sakelar 254 - 370VDC (sakelar pada 230 VAC) | |||||||||||||
Rentang frekuensi | 47 | |||||||||||||
Efisiensi | 79.5% | 83.5% | 85% | 86% | 88% | 88.5% | 89% | |||||||
Arus AC | 6,8A/115VAC 3,4A/230VAC | |||||||||||||
Lonjakan arus | 60A/115VAC 60A/230VAC | |||||||||||||
Kebocoran arus | <2mA / 240VAC | |||||||||||||
Over Load (Muat lewat) | daya output tetapan 110 140% | |||||||||||||
Tipe proteksi: Mode Hiccup, dipulihkan secara otomatis setelah kondisi kerusakan dihapus | ||||||||||||||
Over Voltage (lewat Tegangan) | 3.8 | 5.75 | 13.8 16,2V | 18 V. 21V | 28.8 - 6V | 41.4 "46,8V" | 55.2 V | |||||||
Tipe proteksi: Mode Hiccup, dipulihkan secara otomatis setelah kondisi kerusakan dihapus | ||||||||||||||
Temperatur lebih tinggi | Mode Hiccup, dipulihkan secara otomatis setelah kondisi kerusakan dihapus | |||||||||||||
Suhu Kerja. | -20 + 70 (lihat "kurva derasi") | |||||||||||||
Kelembapan Kerja | 20 90% RH tanpa kondensasi | |||||||||||||
Suhu Penyimpanan, Kelembapan | -40 +8510, 95% KANAN | |||||||||||||
TEMP. Koefisien | ±0.03%/0 ( ) | |||||||||||||
Getaran | 10 - 5Hz, 5G 10 menit./1 siklus, 60 menit. Masing-masing di sepanjang sumbu X, Y, Z. | |||||||||||||
Standar Keselamatan | UL60950-1 disetujui | |||||||||||||
Tahan Tegangan | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0,5KVAC | |||||||||||||
Resistan isolasi | I/P-O/P, I/P-FG, O/P-FG:100M OHM / 500VDC / 25 70 /% RH | |||||||||||||
Dimensi | 215*115*30MM (L*W*H) | |||||||||||||
Berat | 0,76Kg | |||||||||||||
Berkemas | 15pcs/karton/12,4kg/0,78CU78FT | |||||||||||||
CATATAN | ||||||||||||||
1. Semua parameter YANG TIDAK disebutkan khusus diukur pada input 230VAC, beban tetapan, dan 25 dari temperatur ambien. 2. Riak & derau diukur pada 20MHz dari bandwidth menggunakan kabel pasangan 12" yang terpuntir dihentikan dengan paralel 0,1uf & 47ubf. 3. Toleransi: Termasuk mengatur toleransi, regulasi jalur, dan regulasi beban. 4. Regulasi garis diukur dari garis rendah ke garis tinggi pada beban tetapan. 5. Peraturan beban diukur dari 0% hingga 100% beban tetapan. 6. Catu daya dianggap sebagai komponen yang akan dipasang ke peralatan akhir. Peralatan akhir harus dikonfirmasi ulang bahwa peralatan tersebut masih memenuhi arahan EMC. 7. Lama waktu penyiapan diukur pada penyalaan dingin pertama. Menghidupkan/MEMATIKAN catu daya dengan sangat cepat dapat menyebabkan peningkatan waktu penyetelan. |