Tipe Output: | Tunggal |
---|---|
Garansi: | 2 tahun |
Daya Output: | 51 - 100W |
Tegangan Input: | Full range |
Mode Koneksi: | Catu Daya Pengalihan Seri |
Mode Start: | Catu Daya Pengalihan dengan semangat |
Pemasok dengan izin usaha terverifikasi
SPESIFIKASI | |||||||
OUTPUT | |||||||
Contoh | LRS-100-3.3 | LRS-100-5 | LRS-100-12 | LRS-100-15 | LRS-100-24 | LRS-100-36 | LRS-100-48 |
Tegangan DC | 3.3V | 5V | 12 V. | 15V | 24V | 36V | 48V |
Arus tetapan | 20 A | 18A | 8,5A | 7A | 4,5A | 2.8A | 2,3A |
Rentang saat ini | 0 MASUK 20A | 0 A. | 0 | 0 | 0 | 0 A. | 0 |
Daya Tetapan | 66W | 90W | 102W | 105W | 108W | 100.8W | 10.4W |
Riak & Derau | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | 200mVp-p |
Penyesuaian Tegangan. Rentang | 2.97 | 4.5 - 5,5V | 10.2 | 13.5 V | 21.6 "28,8V" | 32.4 | 43.2 |
Toleransi tegangan | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% |
Regulasi Jalur | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load Regulation (Muat Peraturan) | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Pengaturan, waktu naik | 500ms, 30ms/230VAC 500ms, 30ms/115VAC pada beban penuh | ||||||
Waktu tunggu | 55ms/230VAC 10ms/115VAC pada beban penuh | ||||||
Kisaran Tegangan | 85 - 264VAC 120 - 373 VDC | ||||||
Rentang frekuensi | 47 | ||||||
Efisiensi | 84.50% | 86% | 88% | 88.50% | 90% | 90.50% | 91% |
Arus AC | 1,9A/115VAC 1,2A/230VAC | ||||||
Lonjakan arus | Penyalaan dingin 50A/230VAC | ||||||
Kebocoran arus | <0,75mA / 240VAC | ||||||
Over Load (Muat lewat) | daya output tetapan 110 150% | ||||||
Tipe proteksi: Mode Hiccup, dipulihkan secara otomatis setelah kondisi kerusakan dihapus | |||||||
Over Voltage (lewat Tegangan) | 3.8 | 5.75 | 13.8 16,2V | 18.75 21.75V | 28.8 - 6V | 41.4. 48.6V | 55.2 V |
Jenis perlindungan: Matikan tegangan o/p, hidupkan ulang daya untuk memulihkan | |||||||
Suhu Kerja. | -30 +70 (rujuk ke "kurva derasi") | ||||||
Kelembapan Kerja | 20 90% RH tanpa kondensasi | ||||||
Suhu Penyimpanan, Kelembapan | -40 +8510, 95% KANAN | ||||||
TEMP. Koefisien | ±0.03%/0 () | ||||||
Getaran | 10 - 5Hz, 5G 10 menit./1 siklus, 60 menit. Masing-masing di sepanjang sumbu X, Y, Z. | ||||||
Standar Keselamatan | UL60950-1, TUV EN60950-1, EN60335-1/-2-16, DISETUJUI CCC GB4943 | ||||||
Tahan Tegangan | I/P-O/P:3,75KVAC I/P-FG:2KVAC O/P-FG:1,25KVAC | ||||||
Resistan isolasi | I/P-O/P, I/P-FG, O/P-FG:100M OHM / 500VDC / 25 70 /% RH | ||||||
Emisi EMC | KEPATUHAN TERHADAP EN55022(CISPR22), GB9254 CLASS B, EN55014 EN 61000-3-2,-3 | ||||||
Imunitas EMC | Kesesuaian dengan EN61000-4,4,5,2,3,6,8,11, EN61000-6 2(EN50082-2), tingkat industri berat, kriteria A | ||||||
Dimensi | 129*97*30MM (L*W*H) | ||||||
Berat | 0,34Kg | ||||||
Berkemas | 40pcs/karton/14,6kg/0,92CFT | ||||||
CATATAN | |||||||
1. Semua parameter YANG TIDAK disebutkan khusus diukur pada input 230VAC, beban tetapan, dan 25 dari temperatur ambien. | |||||||
2. Riak & derau diukur pada 20MHz dari bandwidth menggunakan kabel pasangan 12" yang terpuntir dihentikan dengan paralel 0,1uf & 47ubf. | |||||||
3. Toleransi: Termasuk mengatur toleransi, regulasi jalur, dan regulasi beban. | |||||||
4. Regulasi garis diukur dari garis rendah ke garis tinggi pada beban tetapan. | |||||||
5. Peraturan beban diukur dari 0% hingga 100% beban tetapan. | |||||||
6. Catu daya dianggap sebagai komponen yang akan dipasang ke peralatan akhir. Peralatan akhir harus dikonfirmasi ulang bahwa peralatan tersebut masih memenuhi arahan EMC. | |||||||
7. Lama waktu penyiapan diukur pada penyalaan dingin pertama. Menghidupkan/MEMATIKAN catu daya dengan sangat cepat dapat menyebabkan peningkatan waktu penyetelan. |
Pemasok dengan izin usaha terverifikasi