Informasi dasar.
Tidak. Model.
YJV/YJV22/YJV32
Aplikasi
Konstruksi, Di bawah tanah, Industri, Power
Tegangan
Kabel Tegangan Rendah dan sedang
Bahan Inti Kabel
Kawat tembaga Kosong
Sertifikasi
ISO, CE, SABS
Voltage Rating
0.6/1 Kv 3.6/6 Kv
Armor
Steel Tape, Steel Wire or Aluminum Interlocked Arm
Applicable Standard
IEC60502 IEC60331 DIN BS
Max Working Temp
90 Degrees
Max Shott Circuit Temp
250 Degrees
Paket Transportasi
Wooden Drums
Spesifikasi
IEC, ASTM, DIN, BS, GB, Any standard
Deskripsi Produk
Low Voltage 1kV XLPE Insulated Power Cable
Application:
Low Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on;Only the halogen free cables shall be generally produced complied with IEC61034 and 60754.
Designing and manufacturing special power cable according to the other standards required by the
1)0.6/1kV, Single Core, Cu or Al/XLPE/PVC Power Cable;
0.6/1kV, Single Core, Cu or Al/XLPE/PVC/AWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Diameter of Al Wires | Nominal Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight |
Cu Conductor | Al Conductor |
AWA | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA | UnAr | AWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | - | - | 1.4 | - | 5.7 | - | 44 | - | - | - |
2.5 | 2.0 | 0.7 | - | - | 1.4 | - | 6.2 | - | 57 | - | - | - |
4 | 2.6 | 0.7 | - | - | 1.4 | - | 6.7 | - | 74 | - | - | - |
6 | 3.1 | 0.7 | - | - | 1.4 | - | 7.3 | - | 96 | - | - | - |
10 | 3.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 7.9 | 12.4 | 134 | 235 | 74 | 175 |
16 | 4.8 | 0.7 | 1.0 | 0.8 | 1.4 | 1.4 | 8.9 | 13.4 | 196 | 307 | 99 | 209 |
25 | 6.0 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 10.6 | 15.1 | 289 | 417 | 139 | 267 |
35 | 7.1 | 0.9 | 1.0 | 0.8 | 1.4 | 1.4 | 11.7 | 16.2 | 382 | 522 | 172 | 309 |
50 | 8.4 | 1.0 | 1.0 | 1.25 | 1.4 | 1.5 | 13.2 | 18.7 | 503 | 710 | 220 | 427 |
70 | 10.0 | 1.1 | 1.0 | 1.25 | 1.4 | 1.5 | 15.0 | 20.5 | 702 | 936 | 293 | 522 |
95 | 11.7 | 1.1 | 1.0 | 1.25 | 1.5 | 1.5 | 16.8 | 22.4 | 950 | 1209 | 384 | 638 |
120 | 13.3 | 1.2 | 1.0 | 1.6 | 1.5 | 1.6 | 18.6 | 25.1 | 1186 | 1531 | 469 | 806 |
150 | 14.5 | 1.4 | 1.0 | 1.6 | 1.5 | 1.6 | 20.4 | 26.7 | 1458 | 1820 | 567 | 923 |
185 | 16.4 | 1.6 | 1.0 | 1.6 | 1.5 | 1.7 | 22.7 | 29.2 | 1810 | 2219 | 698 | 1105 |
240 | 18.7 | 1.7 | 1.0 | 1.6 | 1.6 | 1.8 | 25.4 | 31.9 | 2348 | 2802 | 889 | 1335 |
300 | 20.4 | 1.8 | 1.0 | 1.6 | 1.7 | 1.8 | 27.4 | 33.7 | 2917 | 3393 | 1091 | 1568 |
400 | 23.2 | 2.0 | 1.2 | 2.0 | 1.8 | 2.0 | 30.9 | 38.5 | 3713 | 4377 | 1379 | 2043 |
500 | 26.4 | 2.2 | 1.2 | 2.0 | 1.9 | 2.1 | 34.7 | 42.3 | 4770 | 5512 | 1767 | 2510 |
630 | 30.0 | 2.4 | 1.2 | 2.0 | 2.1 | 2.2 | 39.1 | 46.5 | 6105 | 6914 | 2248 | 3058 |
800 | 34.0 | 2.6 | 1.4 | 2.5 | 2.2 | 2.4 | 43.6 | 52.6 | 7893 | 9008 | 2867 | 3981 |
1000 | 41.4 | 2.8 | 1.4 | 2.5 | 2.3 | 2.5 | 51.6 | 60.8 | 10189 | 11524 | 3690 | 5025 |
Note:
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 800mm2 are compact round condctor.
1000m2 should be compact round segments conductor.
UnAr: Unarmoured/AWA: Aluminum Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(2) 0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Two Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 10.2 | 13.0 | 14.7 | 110 | 227 | 325 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.2 | 14.0 | 15.7 | 142 | 270 | 378 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.2 | 15.0 | 16.7 | 181 | 321 | 438 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.4 | 16.2 | 17.9 | 233 | 386 | 516 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.3 | 1.7 | 1.5 | 1.7 | 14.8 | 17.6 | 20.2 | 315 | 483 | 763 | 194 | 363 | 643 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.3 | 1.7 | 1.5 | 1.7 | 16.9 | 19.6 | 22.3 | 455 | 646 | 963 | 259 | 450 | 767 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 20.2 | 23.0 | 26.3 | 646 | 892 | 1413 | 363 | 591 | 1112 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.5 | 25.2 | 28.6 | 857 | 1110 | 1682 | 434 | 683 | 1242 |
50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.6 | 28.3 | 31.7 | 1123 | 1411 | 2061 | 555 | 838 | 1474 |
70 | 10.0 | 1.1 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.9 | 22.7 | 25.6 | 29.1 | 1427 | 1692 | 2295 | 591 | 836 | 1382 |
95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.2 | 2.0 | 1.9 | 1.7 | 2.0 | 25.8 | 28.6 | 33.3 | 1935 | 2222 | 3132 | 782 | 1050 | 1914 |
120 | 13.3 | 1.2 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 29.2 | 33.6 | 36.7 | 2431 | 3072 | 3777 | 971 | 1573 | 2226 |
150 | 14.5 | 1.4 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.2 | 31.9 | 36.5 | 39.3 | 2984 | 3696 | 4450 | 1171 | 1845 | 2545 |
185 | 16.4 | 1.6 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 36.5 | 41.2 | 45.4 | 3721 | 4545 | 5840 | 1461 | 2246 | 3442 |
240 | 18.7 | 1.7 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 41.3 | 46.0 | 50.3 | 4841 | 5770 | 7190 | 1924 | 2852 | 4272 |
300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.6 | 44.7 | 49.6 | 53.8 | 6023 | 7041 | 8575 | 2363 | 3381 | 4915 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(3)0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Three Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Three Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 10.7 | 13.5 | 15.2 | 130 | 253 | 355 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.7 | 14.5 | 16.2 | 173 | 308 | 420 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.9 | 15.7 | 17.4 | 227 | 374 | 500 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 14.1 | 16.9 | 18.6 | 297 | 458 | 596 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.7 | 18.4 | 21.1 | 413 | 591 | 886 | 236 | 414 | 709 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.9 | 20.7 | 23.3 | 609 | 811 | 1142 | 314 | 517 | 847 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.5 | 24.3 | 27.6 | 903 | 1145 | 1691 | 451 | 694 | 1240 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.9 | 26.7 | 30.0 | 1187 | 1456 | 2068 | 550 | 814 | 1413 |
50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.3 | 30.2 | 33.6 | 1563 | 1881 | 2571 | 712 | 1025 | 1701 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 1.9 | 26.4 | 29.4 | 33.9 | 2097 | 2403 | 3321 | 849 | 1133 | 1981 |
95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 29.8 | 34.6 | 37.6 | 2834 | 3517 | 4238 | 1111 | 1751 | 2420 |
120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.3 | 33.2 | 38.2 | 42.4 | 3560 | 4332 | 5510 | 1377 | 2105 | 3226 |
150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 37.9 | 42.5 | 46.9 | 4406 | 5247 | 6577 | 1693 | 2492 | 3762 |
185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.5 | 42.9 | 47.8 | 52.1 | 5491 | 6476 | 7960 | 2109 | 3050 | 4473 |
240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.6 | 48.0 | 53.1 | 57.4 | 7144 | 8261 | 9914 | 2707 | 3779 | 5368 |
300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 52.5 | 57.5 | 61.8 | 8903 | 10119 | 11914 | 3337 | 4508 | 6235 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(4)0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
mm2 | mm | mm | mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 22.6 | 25.4 | 28.7 | 1064 | 1318 | 1890 | 514 | 769 | 1340 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.6 | 27.4 | 30.7 | 1340 | 1617 | 2241 | 610 | 883 | 1509 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.4 | 31.4 | 34.7 | 1808 | 2139 | 2870 | 807 | 1134 | 1851 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 29.7 | 32.6 | 37.3 | 2446 | 2789 | 3831 | 988 | 1309 | 2280 |
95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.7 | 38.1 | 41.1 | 3313 | 4049 | 4865 | 1307 | 2000 | 2764 |
120 | 13.3 | 1.2 | 70 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 36.3 | 40.9 | 43.9 | 4223 | 5033 | 5913 | 1631 | 2396 | 3223 |
150 | 14.5 | 1.4 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.1 | 2.4 | 41.3 | 46.0 | 50.2 | 5061 | 5993 | 7415 | 1940 | 2826 | 4190 |
185 | 16.4 | 1.6 | 95 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 46.6 | 51.4 | 55.6 | 6400 | 7446 | 9076 | 2453 | 3454 | 4983 |
240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 52.4 | 57.3 | 61.8 | 8291 | 9484 | 11337 | 3137 | 4284 | 6032 |
300 | 20.4 | 1.8 | 150 | 1.5 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.8 | 58.0 | 63.0 | 67.1 | 10322 | 11659 | 13632 | 3864 | 5155 | 7058 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(5)0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Four Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Four Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 11.5 | 14.3 | 16.0 | 156 | 288 | 398 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.7 | 15.4 | 17.2 | 211 | 355 | 478 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 13.9 | 16.7 | 19.3 | 279 | 438 | 704 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.4 | 18.1 | 20.8 | 370 | 544 | 831 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 17.1 | 19.8 | 22.5 | 527 | 720 | 1036 | 286 | 479 | 795 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 19.5 | 22.3 | 25.6 | 778 | 999 | 1509 | 386 | 607 | 1116 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 23.6 | 26.4 | 29.7 | 1161 | 1427 | 2025 | 559 | 825 | 1423 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.8 | 26.3 | 29.1 | 32.6 | 1533 | 1828 | 2519 | 690 | 981 | 1658 |
50 | 8.4 | 1.0 | 1.2 | 1.0 | 0.2 | 2.0 | 1.7 | 1.6 | 1.9 | 30.1 | 33.0 | 37.3 | 2029 | 2379 | 3410 | 890 | 1235 | 2243 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.8 | 1.7 | 2.1 | 30.7 | 35.2 | 38.5 | 2764 | 3443 | 4222 | 1104 | 1739 | 2467 |
95 | 11.7 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 2.0 | 2.2 | 35.3 | 40.1 | 43.1 | 3746 | 4551 | 5417 | 1454 | 2212 | 3026 |
120 | 13.3 | 1.2 | 1.3 | 1.4 | 0.5 | 2.5 | 2.0 | 2.0 | 2.4 | 38.0 | 43.0 | 47.4 | 4697 | 5578 | 6942 | 1790 | 2624 | 3890 |
150 | 14.5 | 1.4 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 43.8 | 48.4 | 52.9 | 5816 | 6785 | 8368 | 2203 | 3126 | 4609 |
185 | 16.4 | 1.6 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.6 | 48.2 | 53.1 | 57.5 | 7239 | 8342 | 10050 | 2734 | 3791 | 5395 |
240 | 18.7 | 1.7 | 1.5 | 1.5 | 0.5 | 2.5 | 2.4 | 2.4 | 2.8 | 53.9 | 59.0 | 63.6 | 9424 | 10676 | 12612 | 3514 | 4718 | 6545 |
300 | 20.4 | 1.8 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.5 | 3.0 | 61.5 | 66.6 | 71.2 | 11782 | 13205 | 15361 | 4366 | 5742 | 7824 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(6)0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,4C+E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.9 | 27.7 | 31.0 | 1337 | 1618 | 2255 | 621 | 901 | 1539 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 27.4 | 30.4 | 33.7 | 1709 | 2028 | 2733 | 753 | 1068 | 1759 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.2 | 0.2 | 2.0 | 1.8 | 1.7 | 2.0 | 31.8 | 34.8 | 39.4 | 2313 | 2681 | 3808 | 1009 | 1372 | 2476 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.1 | 33.2 | 37.6 | 40.7 | 3129 | 3857 | 4653 | 1340 | 2127 | 3000 |
95 | 11.7 | 1.1 | 50 | 1.3 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.3 | 37.6 | 42.2 | 45.2 | 4226 | 5064 | 5975 | 1755 | 2658 | 3616 |
120 | 13.3 | 1.2 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 42.3 | 47.0 | 51.1 | 5402 | 6356 | 7786 | 2244 | 3291 | 4882 |
150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.4 | 2.2 | 2.5 | 45.7 | 50.4 | 54.7 | 6489 | 7515 | 9080 | 2641 | 3779 | 5532 |
185 | 16.4 | 1.6 | 95 | 1.5 | 1.5 | 0.5 | 2.5 | 2.5 | 2.4 | 2.7 | 50.6 | 55.5 | 59.9 | 8171 | 9323 | 11084 | 3329 | 4625 | 6592 |
240 | 18.7 | 1.7 | 120 | 1.6 | 1.5 | 0.5 | 2.5 | 2.7 | 2.6 | 2.9 | 57.0 | 62.2 | 66.3 | 10599 | 11940 | 13888 | 4233 | 5738 | 7873 |
300 | 20.4 | 1.8 | 150 | 1.7 | 1.5 | 0.5 | 3.15 | 2.9 | 2.8 | 3.1 | 63.3 | 68.9 | 74.0 | 13205 | 14742 | 17671 | 5200 | 6914 | 10136 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(7)0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,Five Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,Five Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.8 | 28.6 | 31.9 | 1411 | 1701 | 2366 | 658 | 949 | 1614 |
35 | 7.1 | 0.9 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.6 | 1.8 | 28.9 | 31.9 | 35.2 | 1889 | 2226 | 2954 | 832 | 1163 | 1878 |
50 | 8.4 | 1.0 | 1.2 | 1.2 | 0.2 | 2.0 | 1.9 | 1.8 | 2.0 | 33.4 | 36.4 | 40.9 | 2498 | 2883 | 4040 | 1110 | 1489 | 2623 |
70 | 10.0 | 1.1 | 1.2 | 1.2 | 0.5 | 2.0 | 2.0 | 1.9 | 2.2 | 36.6 | 41.1 | 44.3 | 3470 | 4271 | 5184 | 1471 | 2296 | 3211 |
95 | 11.7 | 1.1 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.3 | 41.3 | 45.9 | 50.1 | 4706 | 5621 | 7080 | 1940 | 2883 | 4353 |
120 | 13.3 | 1.2 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.2 | 2.4 | 45.9 | 50.8 | 54.9 | 5910 | 6962 | 8538 | 2426 | 3533 | 5179 |
150 | 14.5 | 1.4 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 51.5 | 56.4 | 60.5 | 7299 | 8476 | 10212 | 2948 | 4178 | 5981 |
185 | 16.4 | 1.6 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.5 | 61.6 | 65.9 | 9097 | 10407 | 12338 | 3685 | 5084 | 7136 |
240 | 18.7 | 1.7 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.7 | 3.0 | 63.8 | 69.2 | 73.2 | 11840 | 13363 | 15505 | 4704 | 6322 | 8574 |
300 | 20.4 | 1.8 | 1.7 | 1.7 | 0.5 | 3.15 | 3.0 | 2.9 | 3.2 | 70.7 | 76.3 | 81.7 | 14765 | 16474 | 19793 | 5783 | 7591 | 11067 |
1.5mm2 to 6mm2 are normal round stranded conductor, 10mm2 to 50mm2 are compact round condctor.
Above 70m2 are compact semicircle conductor.
UnAr: Unarmoured/STA: Double Steel Tape Armoured/SWA: Galvanized Steel Wire Amoured
Only the halogen free cables shall be generally complied with IEC61034 and 60754.
(8)0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,,Cu or Al/XLPE/PVC/STA/PVC Power Cable;
0.6/ 1kV ,3C+2E Cores,Cu or Al/XLPE/PVC/SWA/PVC Power Cable;
Nominal Cross Section | Approx. Overall Diameter of Conductor | Nominal Thickness of XLPE Insulation | Nominal Cross Section of Earth Conductor | Nominal Thickness of PVC Inner Sheath | Thickness of Steel Tape or Diameter of Steel Wire | Thickness of PVC Outer Sheath | Approx.Overall Diameter | Approx. Weight Cable |
Cu Conductor | Al Conductor |
STA | SWA | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA | UnAr | STA | SWA |
mm2 | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | kg/km | kg/km |
1.5 | 1.6 | 0.7 | 1.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 12.3 | 15.1 | 16.8 | 182 | 324 | 444 | - | - | - |
2.5 | 2.0 | 0.7 | 2.5 | 1.2 | 1.0 | 0.2 | 0.8 | 1.7 | 1.5 | 1.7 | 13.7 | 16.4 | 18.2 | 249 | 404 | 537 | - | - | - |
4 | 2.6 | 0.7 | 4 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 15.1 | 17.9 | 20.5 | 334 | 506 | 784 | - | - | - |
6 | 3.1 | 0.7 | 6 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 16.7 | 19.5 | 22.1 | 446 | 635 | 944 | - | - | - |
10 | 3.8 | 0.7 | 10 | 1.2 | 1.0 | 0.2 | 1.25 | 1.7 | 1.5 | 1.7 | 18.6 | 21.3 | 24.0 | 636 | 846 | 1192 | 335 | 545 | 891 |
16 | 4.8 | 0.7 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 21.3 | 24.1 | 27.4 | 953 | 1194 | 1741 | 463 | 704 | 1251 |
25 | 6.0 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 24.0 | 26.8 | 30.1 | 1234 | 1505 | 2116 | 578 | 849 | 1460 |
35 | 7.1 | 0.9 | 16 | 1.2 | 1.0 | 0.2 | 1.6 | 1.7 | 1.5 | 1.7 | 25.9 | 28.7 | 32.0 | 1506 | 1797 | 2462 | 679 | 966 | 1617 |
50 | 8.4 | 1.0 | 25 | 1.2 | 1.0 | 0.2 | 1.6 | 1.8 | 1.7 | 1.9 | 30.4 | 33.3 | 36.6 | 2078 | 2429 | 3200 | 922 | 1269 | 2027 |
70 | 10.0 | 1.1 | 35 | 1.2 | 1.2 | 0.5 | 2.0 | 1.9 | 1.8 | 2.0 | 32.3 | 36.7 | 39.7 | 2817 | 3527 | 4307 | 1201 | 1950 | 2773 |
95 | 11.7 | 1.1 | 50 | 1.2 | 1.2 | 0.5 | 2.0 | 2.1 | 2.0 | 2.2 | 36.6 | 41.0 | 44.0 | 3813 | 4611 | 5487 | 1593 | 2436 | 3348 |
120 | 13.3 | 1.2 | 70 | 1.3 | 1.4 | 0.5 | 2.5 | 2.2 | 2.0 | 2.4 | 41.9 | 46.5 | 50.9 | 4967 | 5894 | 7365 | 2044 | 3027 | 4569 |
150 | 14.5 | 1.4 | 70 | 1.4 | 1.4 | 0.5 | 2.5 | 2.3 | 2.1 | 2.4 | 44.7 | 49.5 | 53.7 | 5764 | 6773 | 8305 | 2343 | 3418 | 5052 |
185 | 16.4 | 1.6 | 95 | 1.5 | 1.4 | 0.5 | 2.5 | 2.4 | 2.3 | 2.6 | 50.0 | 54.9 | 59.0 | 7353 | 8496 | 10216 | 2975 | 4199 | 6006 |
240 | 18.7 | 1.7 | 120 | 1.5 | 1.5 | 0.5 | 2.5 | 2.6 | 2.5 | 2.8 | 56.2 | 61.3 | 65.6 | 9461 | 10763 | 12700 | 3778 | 5171 | 7227 |
300 | 20.4 | 1.8 | 150 | 1.6 | 1.5 | 0.5 | 2.5 | 2.8 | 2.6 | 3.0 | 62.7 | 67.9 | 72.0 | 11766 | 13238 | 15382 | 4632 | 6193 | 8413 |
Factory viewQC&Testing machineCustomer visitLoading details
Alamat:
Building 18, No. 283 Xisanhuan Road, High-Tech District, Zhengzhou, Henan, China
Jenis Usaha:
Produsen/Pabrik
Jangkauan Bisnis:
Listrik & Elektronik
Sertifikasi Sistem Manajemen:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Produk Utama:
Kabel, Kabel Daya, Kabel Listrik, konduktor telanjang, ACSR, Kabel Ekstra, AAC, AAAC, ABC, Kabel Berinsulasi XLPE, Kabel Opgw
Pengenalan Perusahaan:
Henan Jiapu Cable Group berlokasi di Zhengzhou, ibukota Henan propinsi, juga politik, budaya, ekonomi dan pusat transportasi. Kelompok ini memiliki 3 perusahaan anak perusahaan yang mengkhususkan diri dalam bidang manufaktur dan menyediakan berbagai jenis kabel dan kawat. Dengan upaya dan pengembangan lebih dari 15 tahun, perusahaan tersebut telah menjadi produsen kabel dan kawat yang berpengaruh dalam membuat mesin di Cina.
Produk utama adalah sebagai berikut:
Konduktor telanjang (AAC, AAAC, ACSR, ACAR, AACSR, ACSR/AW)
Kabel Bundel 1kV-35kV (Kabel ABC)
Kabel PVC Terpadu (Fleksibel) dan Kabel Daya PVC terisolasi dan Berpelindung (digosok)
Rendah, sedang, Tegangan Tinggi (1kV-220kV) XLPE Terinsulasi (armor)
Kabel pengelasan, Kabel Kontrol, Kabel
Serat Karet,
Kabel Serat Optik Modular set tegangan, insulator, peredam getaran, kotak sambungan, Terminal diset, penangkal petir, dll. )
Kami dapat merancang dan membuat kabel & kabel sesuai dengan standar GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, Produk-produk kami telah dipasok luas ke berbagai fasilitas pembangkit listrik, distributor bahan listrik, dan dealer, perusahaan konstruksi dan rekayasa, kontraktor-kontraktor listrik, atau perusahaan industri di seluruh dunia, serta Afrika, Timur Tengah, Asia Tenggara, Amerika Selatan, Amerika Tengah, Amerika Utara, Eropa, Australia dan lain-lain. Selamat datang di pesanan OEM dan ODM Anda.
Kami bekerja keras sepanjang waktu untuk meningkatkan lini produksi, mengembangkan produk baru, berfokus pada kebutuhan pelanggan, dan mencoba yang terbaik untuk menawarkan layanan profesional terbaik, berupaya memenuhi kebutuhan pelanggan. Kita menjalankan tujuan "mutu, reputasi, dan pelayanan yang lebih dulu" dan mematuhi prinsip dagang "kesetaraan dan keuntungan bersama". Kita memenangkan kepercayaan pelanggan domestik dan pelanggan dari berbagai negara. Kita akan mengambil semangat perusahaan dalam "Kesatuan dan berjuang, menentukan, dan Berinovasi, pelopor dan kemajuan, kejujuran dan menjadi mematuhi hukum". Dan kita akan bekerja sama dengan teman-teman dari berbagai kalangan baik di dalam maupun luar negeri dengan isyarat baru.