0.6/1KV-Aksesori Kabel dingin
Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) | Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) |
0.6/1kV 3-core Kit Penghentian dingin Shrinkable | VLZ-1/3.0 | 10-16 | 0.6/1kV 3-core Cold Shrinkable Joint | VLJ-1/3.0 | 10-16 |
VLZ-1/3.1 | 25-50 | VLJ-1/3.1 | 25-50 | ||
VLZ-1/3.2 | 70-120 | VLJ-1/3.2 | 70-120 | ||
VLZ-1/3.3 | 150-240 | VLJ-1/3.3 | 150-240 | ||
VLZ-1/3.4 | 300-400 | VLJ-1/3.4 | 300-400 | ||
0.6/1kV 4-core Kit Penghentian dingin Shrinkable | VLZ-1/4.0 | 10-16 | 0.6/1kV 4-core Cold Shrinkable Joint | VLJ-1/4.0 | 10-16 |
VLZ-1/4.1 | 25-50 | VLJ-1/4.1 | 25-50 | ||
VLZ-1/4.2 | 70-120 | VLJ-1/4.2 | 70-120 | ||
VLZ-1/4.3 | 150-240 | VLJ-1/4.3 | 150-240 | ||
VLZ-1/4.4 | 300-400 | VLJ-1/4.4 | 300-400 | ||
0.6/1kV 5-core Kit Penghentian dingin Shrinkable | VLZ-1/5.0 | 10-16 | 0.6/1kV 5-core Cold Shrinkable Joint | VLJ-1/5.0 | 10-16 |
VLZ-1/5.1 | 25-50 | VLJ-1/5.1 | 25-50 | ||
VLZ-1/5.2 | 70-120 | VLJ-1/5.2 | 70-120 | ||
VLZ-1/5.3 | 150-240 | VLJ-1/5.3 | 150-240 | ||
VLZ-1/5.4 | 300-400 | VLJ-1/5.4 | 300-400 |
Proyek Uji | Persyaratan Standar | Hasil Uji/Kesimpulan | |||
Uji Tegangan Frekuensi Daya | 4kV/1mnt,tanpa henti melayang tanpa melayang | Lulus,memenuhi persyaratan | |||
Uji Tegangan Frekuensi Daya | 2,4kV/4 jam,tanpa menyebabkan siapapun yang melayang | Lulus,memenuhi persyaratan |
Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) | Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) |
8.7/15kV 3-core Kit Penghentian ruang dingin yang dapat diminum | VLN-10/3.1 | 25-50 | Kit Penghentian dalam ruang satu Inti Tunggal 8.7/15kV | VLN-10/1.1 | 25-50 |
VLN-10/3.2 | 70-120 | VLN-10/1.2 | 70-120 | ||
VLN-10/3.3 | 150-240 | VLN-10/1.3 | 150-240 | ||
VLN-10/3.4 | 300-400 | VLN-10/1.4 | 300-400 | ||
VLN-10/3.5 | 500-630 | VLN-10/1.5 | 500-630 | ||
Kit Penghentian ruang secara luar-ruang 3/15kV 8.7-core | VLW-10/3.1 | 25-50 | Kit Penghentian ruang secara luar-ruang Inti Tunggal 8.7/15kV | VLW-10/1.1 | 25-50 |
VLW-10/3.2 | 70-120 | VLW-10/1.2 | 70-120 | ||
VLW-10/3.3 | 150-240 | VLW-10/1.3 | 150-240 | ||
VLW-10/3.4 | 300-400 | VLW-10/1.4 | 300-400 | ||
VLW-10/3.5 | 500-630 | VLW-10/1.5 | 500-630 | ||
8.7/15kV 3-core Cold Shrinkable Joint | VLJ-10/3.1 | 25-50 | 8.7/15kV satu Sambungan dingin yang bisa diminum | VLJ-10/1.1 | 25-50 |
VLJ-10/3.2 | 70-120 | VLJ-10/1.2 | 70-120 | ||
VLJ-10/3.3 | 150-240 | VLJ-10/1.3 | 150-240 | ||
VLJ-10/3.4 | 300-400 | VLJ-10/1.4 | 300-400 | ||
VLJ-10/3.5 | 500-630 | VLJ-10/1.5 | 500-630 |
Proyek Uji | Persyaratan Standar | Hasil Uji/Kesimpulan | |||
Tegangan Frekuensi Daya | 39kV 5mnt tidak Flashover dan bukan Pemutusan | Lulus | |||
Pelepasan sebagian | Di bawah 15kV, Volume pembuangan≤10pc | Lulus | |||
Tes Tegangan Impuls | Di bawah 95kV, ±10 kali,tanpa pecahan tanpa perlu melayang | Jangan Mengambang dan tidak rusak | |||
Siklus beban Tegangan konstan (di udara) | Tegangan yang digunakan konduktor 23kV,dan dipanaskan ke (95-100). Di mana kestabilan temperatur 2H,pendingin 3h, total 3 siklus | Tidak berhenti mengambang dan dinilai oleh hasil tes berikut | |||
Pelepasan sebagian (Pengoperasian normal pada suhu tinggi dan konduktor 5-10) | Di bawah 15kV, Volume pembuangan≤10pc | Lulus | |||
Uji Siklus beban konstan | Tegangan yang digunakan konduktor 23kV, dan dipanaskan ke (95-100). Di mana kestabilan temperatur 2H, pendingin 3h, total 60 siklus | Tidak berhenti mengambang dan dinilai oleh hasil tes berikut | |||
Pelepasan sebagian (Pengoperasian normal pada suhu tinggi dan konduktor 5-10, dan pada suhu sekitar) | Di bawah 15kV, Volume pembuangan≤10pc | Lulus | |||
Uji stabilitas Termal | Pada 23 KA, SHORT circuit 2 kali, tidak ada kerusakan yang terlihat | Lulus | |||
Pengujian stabilitas Dinamis | Pada 81 KA, SHORT circuit 1 kali, tidak ada kerusakan yang terlihat | Lulus | |||
Tes Tegangan Impuls | 95kV, ±10 kali | Jangan Mengambang dan tidak rusak | |||
Tegangan bertahan AC | 23kV, 15 mnt | Jangan Mengambang dan tidak rusak | |||
Tes Temperatur Tide | 11kV, 300h | Tidak Flashover,bukan kerusakan, dan tidak ada Rilis arus berlebih | |||
Tes Penyemprotan SALT | 11kV, 1000h | Tidak Flashover,bukan kerusakan, dan tidak ada Rilis arus berlebih |
Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) | Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) |
Kit Penghentian dalam ruang dengan Engine dingin 18/20kV 3-core | VLN-20/3.1 | 35-70 | Kit Penghentian dalam ruang satu Inti Tunggal 18/20kV | VLN-10/1.1 | 35-70 |
VLN-20/3.2 | 95-185 | VLN-10/1.2 | 95-185 | ||
VLN-20/3.3 | 240-400 | VLN-10/1.3 | 240-400 | ||
VLN-20/3.4 | 500-630 | VLN-10/1.4 | 500-630 | ||
Kit Penghentian ruang secara luar ruangan 18/20kV 3-core | VLW-20/3.1 | 35-70 | Kit Penghentian ruang secara luar-ruang 18/20kV Core | VLW-10/1.1 | 35-70 |
VLW-20/3.2 | 95-185 | VLW-10/1.2 | 95-185 | ||
VLW-20/3.3 | 240-400 | VLW-10/1.3 | 240-400 | ||
VLW-20/3.4 | 500-630 | VLW-10/1.4 | 500-630 | ||
18/20kV 3-core Cold Shrinkable Joint | VLJ-20/3.1 | 35-70 | 18/20kV Sambungan dingin satu Inti | VLJ-10/1.1 | 35-70 |
VLJ-20/3.2 | 95-185 | VLJ-10/1.2 | 95-185 | ||
VLJ-20/3.3 | 240-400 | VLJ-10/1.3 | 240-400 | ||
VLJ-20/3.4 | 500-630 | VLJ-10/1.4 | 500-630 |
Proyek Uji | Persyaratan Standar | Hasil Uji/Kesimpulan | |||
Tegangan Frekuensi Daya | 5,55 kV tidak Flashover dan tidak Breaking | Lulus | |||
Pelepasan sebagian | Di bawah 20kV, Volume pembuangan≤10pc | Lulus | |||
Tes Tegangan Impuls | Di bawah 125kV, ±10 kali,tanpa pecahan tanpa melayang | Jangan Mengambang dan tidak rusak | |||
Siklus beban Tegangan konstan (di udara) | Tegangan yang digunakan konduktor 35 kV, dan dipanaskan (95-100). Di mana kestabilan temperatur 2H,pendingin 3h, total 3 siklus | Tidak berhenti mengambang dan dinilai oleh hasil tes berikut | |||
Pelepasan sebagian (Pengoperasian normal pada suhu tinggi dan konduktor 5-10) | Di bawah 20kV, Volume pembuangan≤10pc | Lulus | |||
Uji Siklus beban konstan | Tegangan yang digunakan konduktor 35 kV, dan dipanaskan (95-100). Di mana kestabilan temperatur 2H, pendingin 3h, total 60 siklus | Tidak berhenti mengambang dan dinilai oleh hasil tes berikut | |||
Pelepasan sebagian (Pengoperasian normal pada suhu tinggi dan konduktor 5-10, dan pada suhu sekitar) | Di bawah 20kV, Volume pembuangan≤10pc | Lulus | |||
Uji stabilitas Termal | Pada 23 KA, SHORT circuit 2 kali, tidak ada kerusakan yang terlihat | Lulus | |||
Pengujian stabilitas Dinamis | Pada 81 KA, SHORT circuit 1 kali, tidak ada kerusakan yang terlihat | Lulus | |||
Tes Tegangan Impuls | 125 kV, ±10 kali | Jangan Mengambang dan tidak rusak | |||
Tegangan bertahan AC | 30kV, 15 mnt | Jangan Mengambang dan tidak rusak | |||
Tes Temperatur Tide | 15kV, 300h | Tidak Flashover,bukan kerusakan, dan tidak ada Rilis arus berlebih | |||
Tes Penyemprotan SALT | 15kV, 1000h | Tidak Flashover,bukan kerusakan, dan tidak ada Rilis arus berlebih |
Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) | Nama | No. Item | Menyesuaikan area bagian kabel (sqlmm) |
26/35kV 3-core Kit Penghentian Start dalam ruang yang dingin Drini | VLN-35/3.1 | 50-95 | Kit Penghentian dalam ruang 26/35kV satu Inti yang dapat diminum | VLN-35/1.1 | 35-70 |
VLN-35/3.2 | 120-185 | VLN-35/1.2 | 95-185 | ||
VLN-35/3.3 | 240-400 | VLN-35/1.3 | 240-400 | ||
VLN-35/3.4 | 500-630 | VLN-35/1.4 | 500-630 | ||
Kit Penghentian ruang 3-core dingin yang dapat diminum/35kV 26 | VLW-35/3.1 | 50-95 | Kit Penghentian ruang 26/35kV satu Inti dingin yang dapat diminum | VLW-35/1.1 | 35-70 |
VLW-35/3.2 | 120-185 | VLW-35/1.2 | 95-185 | ||
VLW-35/3.3 | 240-400 | VLW-35/1.3 | 240-400 | ||
VLW-35/3.4 | 500-630 | VLW-35/1.4 | 500-630 | ||
26/35kV 3-core Cold Shrinkable Joint | VLJ-35/3.1 | 50-95 | 26/35kV satu Sambungan dingin yang bisa diminum | VLJ-35/1.1 | 35-70 |
VLJ-35/3.2 | 120-185 | VLJ-35/1.2 | 95-185 | ||
VLJ-35/3.3 | 240-400 | VLJ-35/1.3 | 240-400 | ||
VLJ-35/3.4 | 500-630 | VLJ-35/1.4 | 500-630 |
Proyek Uji | Persyaratan Standar | Hasil Uji/Kesimpulan | |||
Tegangan Frekuensi Daya | 105kV 1mnt bukan Flashover (melayang) dan bukan rincian | Lulus | |||
Pelepasan sebagian | Di bawah 39kV, Volume pembuangan≤10pc | Lulus | |||
Siklus beban Tegangan konstan (di udara) | Tegangan yang digunakan konduktor 23kV,dan dipanaskan ke (95-100). Di mana kestabilan temperatur 2H,pendingin 3h, total 3 siklus | Tidak berhenti mengambang dan dinilai oleh hasil tes berikut | |||
Tes Tegangan Impuls | Di bawah 250 kV, ±10 kali,tidak ada kerusakan yang mengapung | Jangan Mengambang dan tidak rusak | |||
Tegangan DC | 156kV, 15 mnt | Jangan Mengambang dan tidak rusak | |||
Tegangan bertahan AC | 104kV, 4h | Jangan Mengambang dan tidak rusak |