Type: | Insulated |
---|---|
Conductor Type: | Stranded |
Application: | Overhead |
Conductor Material: | Aluminum |
Sheath Material: | Crosslinking |
Insulation Material: | PE |
Pemasok dengan izin usaha terverifikasi
0.6/1kv CU/XLPE/SWA/kabel daya inti PVC 4 mm
600/1000 V-DUA KONDUKTOR TEMBAGA XLPE TERISOLASI SWA PVC KABEL (CU/XLPE/PVC/SWA/PVC)
AREA NOMINAL KONDUKTOR | RESISTAN KONDUKTOR MAKSIMUM PADA 20 C | KETEBALAN INSULASI | KETEBALAN PERANGKAT TIDUR EKSTRUSI | DIA (DIA). DARI KABEL BAJA | KETEBALAN SELUBUNG LUAR | PERKIRAAN KESELURUHAN DIAMETER | PERKIRAAN BERAT KABEL | PANJANG KEMASAN STANDAR | UKURAN DRUM | PERKIRAAN BERAT KOTOR |
Sqmm | Ohm/km | mm | mm | mm | mm | mm | Kg/km | Meter±10 % | KG | |
1.5* | 12.1 | 0.7 | 1 | 0.9 | 1.8 | 14.2 | 355 | 1000 | D-10 | 415 |
1.5 | 12.1 | 0.7 | 1 | 0.9 | 1.8 | 14.6 | 370 | 1000 | D-10 | 430 |
2.5* | 7.41 | 0.7 | 1 | 0.9 | 1.8 | 15 | 400 | 1000 | D-10 | 460 |
2.5 | 7.41 | 0.7 | 1 | 0.9 | 1.8 | 15.4 | 415 | 1000 | D-10 | 475 |
4 | 4.61 | 0.7 | 1 | 0.9 | 1.8 | 16.4 | 480 | 1000 | D-11 | 580 |
6 | 3.08 | 0.7 | 1 | 0.9 | 1.8 | 17.6 | 570 | 1000 | D-11 | 670 |
10 | 1.83 | 0.7 | 1 | 1.25 | 1.8 | 20.3 | 820 | 1000 | D-12 | 930 |
16 | 1.15 | 0.7 | 1 | 1.25 | 1.8 | 22.3 | 1030 | 1000 | D-14 | 1180 |
25 | 0.727 | 0.9 | 1 | 1.6 | 1.8 | 26.3 | 1530 | 1000 | D-16 | 1740 |
35 | 0.524 | 0.9 | 1 | 1.6 | 1.8 | 28.5 | 1840 | 1000 | D-18 | 2080 |
50 | 0.387 | 1 | 1 | 1.6 | 1.8 | 30.9 | 2070 | 500 | D-14 | 1190 |
70 | 0.268 | 1.1 | 1 | 1.6 | 2 | 34.9 | 2670 | 500 | D-16 | 1545 |
95 | 0.193 | 1.1 | 1.2 | 2 | 2.1 | 40.1 | 3660 | 500 | D-18 | 2070 |
120 | 0.153 | 1.2 | 1.2 | 2 | 2.2 | 43.7 | 4350 | 500 | D-18 | 2420 |
150 | 0.124 | 1.4 | 1.2 | 2 | 2.3 | 47.5 | 5160 | 500 | D-19 | 2900 |
185 | 0.0991 | 1.6 | 1.4 | 2.5 | 2.5 | 53.3 | 6600 | 250 | D-18 | 1895 |
240 | 0.0754 | 1.7 | 1.4 | 2.5 | 2.7 | 59.1 | 8100 | 250 | D-18 | 2270 |
300 | 0.0601 | 1.8 | 1.6 | 2.5 | 2.8 | 64.1 | 9660 | 250 | D-18 | 2660 |
400 | 0.047 | 2 | 1.6 | 2.5 | 3.1 | 71.3 | 12000 | 250 | D-21 | 3425 |
500 | 0.0366 | 2.2 | 1.6 | 3.15 | 3.3 | 79.8 | 15500 | 250 | D-23 | 4375 |
*konduktor melingkar (Kelas 1).
Semua konduktor melingkar atau terpilin (Kelas 2) yang lain.
Kabel sesuai dengan BS 5467 dan umumnya sesuai dengan IEC 60502 - 1.
600/1000V-TIGA KONDUKTOR TEMBAGA XLPE TERISOLASI SWA PVC SHEA PVC (CU/XLPE/PVC/SWA/PVC)
AREA NOMINAL KONDUKTOR | RESISTAN KONDUKTOR MAKSIMUM PADA 20 C | KETEBALAN INSULASI | KETEBALAN TEMPAT TIDUR | DIA (DIA). DARI KABEL BAJA | KETEBALAN SELUBUNG LUAR | PERKIRAAN KESELURUHAN DIAMETER | PERKIRAAN BERAT KABEL | PANJANG KEMASAN STANDAR | UKURAN DRUM | PERKIRAAN BERAT KOTOR | ||||
Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | |||||||
Sqmm | Ohm/km | mm | mm | mm | mm | mm | Kg/km | Meter±10 % | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.3 | - | 330 | - | 1000 | D-10 | 390 | - |
1.5 | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.7 | - | 350 | - | 1000 | D-10 | 410 | - |
2.5* | 7.41 | 0.7 | 0.8 | - | 0.9 | 1.4 | 14.4 | - | 390 | - | 1000 | D-10 | 450 | - |
2.5 | 7.41 | 0.7 | 0.8 | 0.9 | 1.4 | 14.8 | - | 415 | - | 1000 | D-10 | 475 | - | |
4 | 4.61 | 0.7 | 0.8 | - | 0.9 | 1.4 | 15.9 | - | 490 | - | 1000 | D-11 | 590 | - |
6 | 3.08 | 0.7 | 0.8 | - | 0.9 | 1.4 | 17.2 | - | 580 | - | 1000 | D-12 | 690 | - |
10 | 1.83 | 0.7 | 0.8 | - | 1.25 | 1.5 | 19.6 | - | 850 | - | 1000 | D-12 | 960 | - |
16 | 1.15 | 0.7 | 0.8 | - | 1.25 | 1.6 | 22.2 | - | 1110 | - | 1000 | D-14 | 1260 | - |
25 | 0.727 | 0.9 | 1 | 0.8 | 1.6 | 1.7 | 24.3 | 23.2 | 1520 | 1420 | 500 | D-11 | 870 | 810 |
35 | 0.524 | 0.9 | 1 | 0.8 | 1.6 | 1.8 | 26.9 | 25.8 | 1910 | 1790 | 500 | D-12 | 1065 | 1010 |
50 | 0.387 | 1 | 1 | 0.8 | 1.6 | 1.8 | 30.1 | 29 | 2400 | 2250 | 500 | D-12 | 1350 | 1230 |
70 | 0.268 | 1.1 | 1 | 0.8 | 1.6 | 1.9 | 32.8 | 31.7 | 3100 | 2950 | 500 | D-14 | 1700 | 1630 |
95 | 0.193 | 1.1 | 1.2 | 0.8 | 2 | 2.1 | 38.2 | 36.7 | 4310 | 4060 | 500 | D-16 | 2400 | 2270 |
120 | 0.153 | 1.2 | 1.2 | 0.8 | 2 | 2.2 | 41.8 | 40.3 | 5170 | 4920 | 500 | D-18 | 2830 | 2700 |
150 | 0.124 | 1.4 | 1.4 | 0.8 | 2.5 | 2.3 | 46.4 | 44.5 | 6620 | 6290 | 500 | D-18 | 3550 | 3390 |
185 | 0.0991 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 50.8 | 48.9 | 7860 | 7510 | 250 | D-18 | 2210 | 2090 |
240 | 0.0754 | 1.7 | 1.4 | 0.8 | 2.5 | 2.6 | 56.9 | 55 | 9810 | 9410 | 250 | D-18 | 2690 | 2590 |
300 | 0.0601 | 1.8 | 1.6 | 0.8 | 2.5 | 2.7 | 61.8 | 59.5 | 11910 | 11430 | 250 | D-18 | 3220 | 3100 |
400 | 0.047 | 2 | 1.6 | 0.8 | 2.5 | 2.9 | 69.2 | 66.9 | 14910 | 14330 | 250 | D-19 | 3300 | 3110 |
*konduktor melingkar (Kelas 1).
Konduktor yang termasuk melingkar 163,8 mm (Kelas 2).
25sql8 mm dan konduktor bentuk di atasnya(Kelas 2)
Kabel sesuai dengan BS 5467 dan umumnya sesuai dengan IEC 60502-1.
600/1000V-EMPAT KONDUKTOR TEMBAGA INTI XLPE TERISOLASI KABEL PVC TERISOLASI DAN SHELT (CU/XLPE/PVC/SWA/PVC)
AREA NOMINAL KONDUKTOR | RESISTAN KONDUKTOR MAKSIMUM PADA 20 C | KETEBALAN INSULASI | KETEBALAN TEMPAT TIDUR | DIA (DIA). DARI KABEL BAJA | KETEBALAN SELUBUNG LUAR | PERKIRAAN KESELURUHAN DIAMETER | PERKIRAAN BERAT KABEL | PANJANG KEMASAN STANDAR | UKURAN DRUM | PERKIRAAN BERAT KOTOR | ||||
Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | Kasur ekstrusi | Kasur pecah | |||||||
Sqmm | Ohm/km | mm | mm | mm | mm | mm | Kg/km | Meter±10 % | KG | |||||
1.5* | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.3 | - | 330 | - | 1000 | D-10 | 390 | - |
1.5 | 12.1 | 0.7 | 0.8 | - | 0.9 | 1.3 | 13.7 | - | 350 | - | 1000 | D-10 | 410 | - |
2.5* | 7.41 | 0.7 | 0.8 | - | 0.9 | 1.4 | 14.4 | - | 390 | - | 1000 | D-10 | 450 | - |
2.5 | 7.41 | 0.7 | 0.8 | 0.9 | 1.4 | 14.8 | - | 415 | - | 1000 | D-10 | 475 | - | |
4 | 4.61 | 0.7 | 0.8 | - | 0.9 | 1.4 | 15.9 | - | 490 | - | 1000 | D-11 | 590 | - |
6 | 3.08 | 0.7 | 0.8 | - | 0.9 | 1.4 | 17.2 | - | 580 | - | 1000 | D-12 | 690 | - |
10 | 1.83 | 0.7 | 0.8 | - | 1.25 | 1.5 | 19.6 | - | 850 | - | 1000 | D-12 | 960 | - |
16 | 1.15 | 0.7 | 0.8 | - | 1.25 | 1.6 | 22.2 | - | 1110 | - | 1000 | D-14 | 1260 | - |
25 | 0.727 | 0.9 | 1 | 0.8 | 1.6 | 1.7 | 24.3 | 23.2 | 1520 | 1420 | 500 | D-11 | 870 | 810 |
35 | 0.524 | 0.9 | 1 | 0.8 | 1.6 | 1.8 | 26.9 | 25.8 | 1910 | 1790 | 500 | D-12 | 1065 | 1010 |
50 | 0.387 | 1 | 1 | 0.8 | 1.6 | 1.8 | 30.1 | 29 | 2400 | 2250 | 500 | D-12 | 1350 | 1230 |
70 | 0.268 | 1.1 | 1 | 0.8 | 1.6 | 1.9 | 32.8 | 31.7 | 3100 | 2950 | 500 | D-14 | 1700 | 1630 |
95 | 0.193 | 1.1 | 1.2 | 0.8 | 2 | 2.1 | 38.2 | 36.7 | 4310 | 4060 | 500 | D-16 | 2400 | 2270 |
120 | 0.153 | 1.2 | 1.2 | 0.8 | 2 | 2.2 | 41.8 | 40.3 | 5170 | 4920 | 500 | D-18 | 2830 | 2700 |
150 | 0.124 | 1.4 | 1.4 | 0.8 | 2.5 | 2.3 | 46.4 | 44.5 | 6620 | 6290 | 500 | D-18 | 3550 | 3390 |
185 | 0.0991 | 1.6 | 1.4 | 0.8 | 2.5 | 2.4 | 50.8 | 48.9 | 7860 | 7510 | 250 | D-18 | 2210 | 2090 |
240 | 0.0754 | 1.7 | 1.4 | 0.8 | 2.5 | 2.6 | 56.9 | 55 | 9810 | 9410 | 250 | D-18 | 2690 | 2590 |
300 | 0.0601 | 1.8 | 1.6 | 0.8 | 2.5 | 2.7 | 61.8 | 59.5 | 11910 | 11430 | 250 | D-18 | 3220 | 3100 |
400 | 0.047 | 2 | 1.6 | 0.8 | 2.5 | 2.9 | 69.2 | 66.9 | 14910 | 14330 | 250 | D-19 | 3300 | 3110 |
600/1000V-EMPAT KONDUKTOR TEMBAGA INTI XLPE TERISOLASI KABEL PVC TERISOLASI DAN SHELT (CU/XLPE/PVC/SWA/PVC)
*semua konduktor membentuk menggantung(Kelas 2)
Kabel sesuai dengan IEC 60502-1
Ukuran drum yang diberikan di atas adalah untuk kabel dengan perlengkapan tidur ekstrusi
Pemasok dengan izin usaha terverifikasi