• Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller
  • Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller
  • Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller
  • Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller
Favorit

Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller

Aplikasi: Transduser Umum
Tipe Output: Tiga kali
Prinsip kerja: AC to AC Soft Starter
Beralih Mode (Mode Sakelar): PAM Control (Kontrol PAM)
Tipe Sirkuit Utama: Tegangan
Tegangan Catu Daya: Penggerak Frekuensi Variabel Tegangan Rendah

Hubungi Pemasok

Anggota Berlian Harga mulai 2017

Pemasok dengan izin usaha terverifikasi

Klasifikasi: 5.0/5
Produsen/Pabrik

Informasi dasar.

Tidak. Model.
R1-PR500-11KW
Link Transformasi
Penggerak Frekuensi Variabel AC
Sifat Daya DC
Penggerak Frekuensi Variabel Tegangan
Fungsi
Protect The Motor
Merek
Gwiec
formulir output
output analog dc 4-20ma
fase
tiga fase
warna
abu-abu
nama produk
starter lunak
daya
11 kw
material selubung
semua material refraktori
sertifikasi
ce
garansi
24 bulan
Paket Transportasi
Export Standard Carton Box
Spesifikasi
7.5 KW-315 KW
Merek Dagang
Gwiec
Asal
Yueqing
Kode HS
8511409900
Kapasitas Produksi
5000

Deskripsi Produk

Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller 

Introduce

Soft starter are a far better alternative to star/delta and auto transformer starters.
The star/delta starter reduces start current but introduces a damaging torque transient when switching from star to delta connection. Furthermore star/delta starting does not always selection of the best start current level.
This sometimes means the load cannot accelerate to full speed in star configuration thereby making the star/delta
starter totally in effective.

A star/delta starter does not impact the way the motor stops, thus leaving the voltage ramp down with no control. The auto transformer reduces start current but also allows some control over the level of start current. Auto transformer starters does not eliminate the risk of a jump in torque when shifting voltage.

 

Working Condition

1. Power grid, self-provided power plant, electric generator : three phase 380V or 660V (specifical designed)  ±15%, 50Hz or 60Hz, power capacity have to meet soft starter and motor starting requirement

2. Suitable motor: Squirrel cage three-phase asynchronous motor and the motor reated power shall be match with soft starter power 

3. Starting time frequency: no special requirement, depends on the situation

4. Cooling method: Natural air cooling

5. Protection: IP20

6. Environment condition: altitude under 1000meters, temperature: 0 ~ 40 degree Celsius, humidity:  under 90% RH

 

Pump 

1. Reduce hydraulic shocks in pipelines during start and stop.
2. Minimize mechanical stress on motor shaft.
3. Reduce starting current .
4. Under-current protection preventing damage from blocked pipe or low water situations.
5. Automatic reset functionality ensures continued operation of unmanned pump stations.
6. Phase rotation protection prevents damage from reverse pump rotation.
7. Instantaneous overload protection prevents damage from debris drawn into the pump.

 

Fans

1. Smooth application of torque preventing mechanical stress.
2. Reduced starting times over star/delta starting.

Power Supply: City power, Electricity Generator, Input three phase AC 220/380V/440/660V, 50/60Hz, Battery capacity should comply soft starter boot require.

Suitable For : Three phase squirrel cage induction motor, rated frequency should be match with soft starter
Starting Frequency: No Specific Requirement

Cooling : Natural air cooling
Protect Level : IP 20
Environment : Altitude of 3000 meters below;
Ambient temperature: -25~+40ºC;
Relative humidity : <90%;
Non-condensing, non-flammable, corrosive gases;
Non-conductive dust, good ventilation, low-vibration.

 

Protection

1. Voltage loss, undervoltage, overvoltage 

2. Over-Current while starting or running

3. Soft starter over heat

4. Starting over time 

5. Input or output phase losses

6. Three phase unbalance 

7. Short circuit

 

5 Mode of Start
Ramp voltage start :Require a smooth start occasion, output voltage as Page 1.
Current limit start : Have strict limitation of starting current, motor current curve as Page 2.
Snap action + Ramp voltage start : For heavy load, static friction force too big cause motor not running, starting curve as 
Snap action + Current limit start : For heavy load, static friction force too big cause motor not running, starting curve as 
Heavy load strong shock start : For difficulty of heavy load motor start

 

5 Level Production Setting:
For different occasions, JJR2 production divide into five level, 0=Elementary ; 1: light load ; 2 : Standard 3 : Heavy load 4 : Advanced, Set by F12 Elementary forbid connect Instantaneous stop function, only have over-heat,
short circuit and default phase protection, suitable for Unconditional emergency start, like fir pump.
Light-load / Standard / Heavy-load has most of protection function, only difference is motor over load heat protection time curve as Page 1 & 5Advance as starting protection is more strict, parameters is like Heavy-load

 

Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller

 

10 Optional Functions
Start delay : 0 ~ 999s, shows as timer, start when it goes "0"
Running delay output : 0 ~ 999s, From received the signal, delay output closing contact
Starting interval delay : 0 ~ 999s, Light flash in this period, time's over allow restart
Over-heat unlock delay : 0 ~999s, after over heat happen and release
Error message storage: Last 9 error message
Auto restart : set for 9 times of auto start, used long-term continuous operation & Unattended occasions
0-20A DC analog output : real-time motor current indicator, max-load 300 Ω
Multiply display: Able to indicator power voltage, motor current, apparent power, thermal equilibrium,etc.

Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller
Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor ControllerProtect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller


Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor ControllerProtect The 11 Kw 15 30 7.5kw Starter Soft Start Motor ControllerProtect The 11 Kw 15 30 7.5kw Starter Soft Start Motor ControllerProtect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller

 

Kirim permintaan informasi Anda langsung ke penyedia ini

*Dari:
*Untuk:
*Pesan:

Masukkan antara 20 dan 4000 karakter.

Ini bukan yang Anda cari? Posting Permintaan Sourcing SEKARANG

Temukan Produk Serupa Berdasarkan Kategori

Beranda Pemasok Produk Lainnya Lainnya Protect The 11 Kw 15 30 7.5kw Starter Soft Start Motor Controller