Tipe Output: | Tunggal |
---|---|
Garansi: | 2 tahun |
Daya Output: | 51 - 100W |
Tegangan Input: | 110-220V |
Mode Koneksi: | Catu Daya Pengalihan Seri |
Mode Start: | Catu Daya Pengalihan dengan semangat terpisah |
Pemasok dengan izin usaha terverifikasi
CONTOH | M DR-60-5 | M DR-60-12 | M DR-60-24 | M DR-60-48 | |
TEGANGAN DC | 5V | 12 V. | 24V | 48V | |
ARUS TETAPAN | 10 A | 5A | 5A | 1,25A | |
RENTANG SAAT INI | 0 - 10A | 0 5A | 0 -2,5A | 0-1,25A | |
DAYA TETAPAN | 50W | 60W | 60W | 60W | |
RIAK & DERAU (maks.) Takada.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
OUTPUT | PENGATURAN TEGANGAN. RENTANG | 5 -6V | 12-15V | 24 - 30V | 48 - 56V |
Catatan TOLERANSI TEGANGAN.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
PENGATURAN JALUR | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
PENGATURAN MUATAN | ±1.5% | ±1.0% | ±1.0% | ±1.0% | |
PENGATURAN, CATATAN WAKTU TERBIT.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC pada beban penuh | ||||
WAKTU TUNGGU (TIP.) | 50ms/230VAC 20ms/115VAC pada beban penuh | ||||
KISARAN TEGANGAN | 85 - 264VAC 120-370VDC | ||||
RENTANG FREKUENSI | 47 | ||||
INPUT (MASUKAN) | EFISIENSI (Tip.) | 78% | 86% | 88% | 87% |
ARUS AC (Tip.) | 1,8 A/115VAC 1A/230VAC | ||||
ARUS TIDAK BURU (Tipikal) | START DINGIN 30A/115VAC,60A/230VAC | ||||
KEBOCORAN ARUS | <1mA/240VAC | ||||
KELEBIHAN BEBAN | daya output tetapan 105 - 150% | ||||
PERLINDUNGAN | Tipe proteksi: Pembatasan arus konstan, pulih secara otomatis setelah kondisi kerusakan dihapus | ||||
TEGANGAN BERLEBIH | 6.25-7,25V | 15.6 - 18V | 31.2-36V | 57.6 - 64,8V | |
Jenis perlindungan: Matikan tegangan o/p, hidupkan ulang daya untuk memulihkan | |||||
FUNGSI | SINYAL OK DC | Peringkat kontak relai (maks.): 30V/1A resistif | |||
SUHU PENGOPERASIAN. | -20 - +70 C (lihat "Kurva penurunan Daya") | ||||
KELEMBAPAN KERJA | 20 90% RH tanpa kondensasi | ||||
LINGKUNGAN | SUHU PENYIMPANAN, KELEMBAPAN | -40 +85 O C, 10 - 95% RH | |||
TEMP. KOEFISIEN | ±0.03% - 0 50 C | ||||
GETARAN | Komponen: 10 - 500Hz, 10 g./1 siklus, jangka waktu 60 mnt. Masing-masing sepanjang X, Y, sumbu Z; Pemasangan: Kepatuhan terhadap IEC60068-2-6 | ||||
STANDAR KESELAMATAN | UL508, UL60950-1, DISETUJUI TUV EN60950-1 | ||||
KESELAMATAN & | TAHAN TEGANGAN | L/P-0/P:3KVAC L/P-FG:2KVAC 0/P-FG:0,5KVAC | |||
EMC | RESISTAN ISOLASI | L/P-O/P, L/P-FG, 0/P-FG:>100M OHM/500VDC/25 C/70% RH | |||
(Catatan 4) | EMISI EMC | Sesuai dengan EN55011, EN55022 (CISPR22), EN61204-3 Kelas B, EN61000-3-2,-3 | |||
IMUNITAS EMC | Kepatuhan terhadap EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, tingkat industri berat, Kriteria A | ||||
MTBF | MIL-HDBK-217F (25 derajat C) | ||||
LAINNYA | DIMENSI | 40*90*100 MM (W*H*D) | |||
BERKEMAS | 0,33Kg; 42pcs/14,8G/0,82CFT | ||||
CATATAN | 1. Semua parameter YANG TIDAK disebutkan khusus diukur pada input 230VAC, beban tetapan dan suhu sekitar 25 C. | ||||
Riak & derau diukur pada 20MHz dari bandwidth menggunakan kabel pasangan 12" yang terpuntir dihentikan dengan kapasitor paralel 0.1 uf & 47uf. 2 | |||||
3. Toleransi : mencakup toleransi pengaturan, regulasi jalur, dan regulasi beban. | |||||
4. Catu daya dianggap sebagai komponen yang akan dipasang ke peralatan akhir. Peralatan akhir harus dikonfirmasi ulang bahwa peralatan tersebut masih memenuhi arahan EMC. Untuk panduan tentang cara menjalankan uji EMC ini, lihat "Tes EMI suplai komponen. | |||||
5. 5.Panjang waktu pengaturan diukur pada penyalaan dingin pertama. Menghidupkan/MEMATIKAN catu daya dapat menyebabkan peningkatan waktu pengaturan. | |||||