• Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
  • Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
  • Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
  • Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
  • Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
  • Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer
Favorit

Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer

Classification: Imaging Diagnostic Equipment
Type: Digital Imaging System
Certification: ISO13485
waran: 1 tahun
Paket Transportasi: Standard Export Package
Spesifikasi: standard

Hubungi Pemasok

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik

Informasi dasar.

Tidak. Model.
CCENT-ST10
Merek Dagang
Comcernmed
Asal
China
Kapasitas Produksi
500units/Month

Deskripsi Produk

medical Ophthalmic Portable Fully Automatic Icare Tonometer 

Model:CCENT-ST10

Medical Ophthalmic Auto 3-D Positioning Portable Fully Automatic Icare Non-Contact Tonometer

Technical parameters          

Basic Specifications

Intraocular pressure (IOP) measuring range: 1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)

Measuring system: dual sensor system of light and pressure

Working distance:≥11mm 

R/L: automatic detection and display

Measuring result: 10 times per eye; 3 times result printing per eye

Recording: build-in printer

Measuring mode: auto/manual

Focus: when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it's good focus, the frame will turn yellow into green, and click to start the measurement

Error indication: if the measurement signal is weak, the IOP will be enclosed by ( ), or display "ERR "

Safety limit button: install measurement for minimum distance between head and patient

Safety functions: the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head. 

Movement range:≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)

Jaw layer vertical movement: 0~65mm with under jaw layer

Display mode: 10.1-inch HDMI color LED touch monitor

Output port: USB2.0

Working platform: electric elevating platform

 

Others

Size:380 mm (L) x 460mm (W) x 505mm (H)

Weight:19.7kg

Power supply: 220V/50HZ

 

Note:with development of technology, specifications and design are subject to change without notice.

 

Product features

 

Auto tonometer utilizes image control and feature recognition for auto 3-D positioning of xyz with reliable judgment and measurement results, and easy to operate. The air non-contact approach to measure IOP can also be used for corneal thickness 

 

Performance Features

 

Auto 3-D positioning of xyz results in precise and reliable measurement

Full-auto measurement for both right and left eye data without manual switch

Easy to operate the tonometer with color touch monitor

Stable data of IOP through soft air measurement

To compensate corneal thickness measurement of IOP


We CONCERNMED make one-stop shopping hospital medical equipment:
 
one-stop shopping
hospital medical equipment
x ray room x ray machine
processor
x ray film
cassette
Intensifying screen
lead clothings(lead glove, lead glasses,
lead cap, lead apron, lead collar)
ultrasound b/w 2D ultrasound
2/3/4D color ultrasound
laboratory room chemistry analyzer
hematology analyzer
microplate elisa reader
microplate washer
centrifuge
pipette
water bath
urine analyzer
operation room anesthesia machine
ventilator
operating lamp
operation table
pendant
medical drill and saw
ECG 
patient monitor 
defibrillator
infusion pump 
electrocoagulation
oxygen generator
electric suction device
autoclave sterilizer
ect.


Medical Ophthalmic Auto 3-D Positioning Portable Fully Automatic Icare Non-Contact Tonometer
Medical Ophthalmic Auto 3-D Positioning Portable Fully Automatic Icare Non-Contact Tonometer
Medical Ophthalmic Auto 3-D Positioning Portable Fully Automatic Icare Non-Contact Tonometer

Kirim permintaan informasi Anda langsung ke penyedia ini

*Dari:
*Untuk:
*Pesan:

Masukkan antara 20 dan 4000 karakter.

Ini bukan yang Anda cari? Posting Permintaan Sourcing SEKARANG

Temukan Produk Serupa Berdasarkan Kategori

Beranda Pemasok Produk THT & mata Tonometer Medical ofthalmic Otomatis 3-D dengan Pengaturan Portabel penuh Otomatis ICARE Non-Kontak Tonometer

Anda Mungkin Juga Menyukai

Grup produk

Hubungi Pemasok

Anggota Berlian Harga mulai 2022

Pemasok dengan izin usaha terverifikasi

Produsen/Pabrik
Ketentuan Pembayaran
LC, T/T., Western Union, Money Gram