After-sales Service: | 10024-97-2 |
---|---|
Warranty: | 1year |
Function: | Storage Pressure Vessel, Heat Pressure Vessel |
Application: | Liquefied Gas |
Material: | Stainless Steel |
Pressure: | 1.6MPa≤p<10.0MPa |
Pemasok dengan izin usaha terverifikasi
tangki mikro-bulk 2m3
Model:CFL-2/2.6
Volume geometrik:2,1M3
Volume efektif:2M3
Tekanan:26bar
Material dalam:S30408
Material luar:S30408
Dimensi eksternal:1800*1800*2696 mm
Lihat produk lainnya, harap klik di sini https://dswgascylinder.en.made-in-china.com/product-group/aeRnSgPJIzhI/Micro-bulk-tank-1.html
Anda juga bisa mengecek di sini, kami memiliki volume yang lebih berbeda 1000L,3000L,5000L dan tekanan kerja 16bar, 22bar dan 34bar
SPESIFIKASI | ||||||||||||||||||
DESKRIPSI | CDL 1/1.6 |
CDL 1.6/1 LNG |
CDLS 1/2.2 CO2 |
CDLS 1/3.4 |
CDLS 2/1.6 |
CDLS 1.6/2 LNG |
CDLS 2/2.2 CO2 |
CDLS 2/3.4 |
CDLS 3/1.6 |
CDLS 1.6/3 LNG |
CDLS 3/2.2 CO2 |
CDLS 3/3.4 |
CFLSX 2/1.6 |
CFLSX 2/3.4 |
CFLSX 3/1.6 |
CFLSX 1.6/3 LNG |
CFLSX 3/2.2 CO2 |
CFLSX 3/3.4 |
Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | Alas Palet | |
KAPASITAS(L) | ||||||||||||||||||
Kotor | 1,060 | 1,112 | 1,060 | 1,060 | 2,100 | 2,200 | 2,100 | 2,100 | 3,230 | 3,400 | 3,230 | 3,230 | 2,100 | 2,100 | 3,230 | 3,400 | 3,230 | 3,230 |
Bersih | 1,000 | 1,000 | 1,000 | 1,000 | 2,000 | 2,000 | 2,000 | 2,000 | 3,000 | 3,000 | 3,000 | 3,000 | 2,000 | 2,000 | 3,000 | 3,000 | 3,000 | 3,000 |
psig | 232 | 232 | 320 | 494 | 232 | 232 | 320 | 494 | 232 | 232 | 320 | 494 | 232 | 494 | 232 | 232 | 320 | 494 |
tongkang | 16.0 | 16.0 | 22.0 | 34.0 | 16.0 | 16.0 | 22.0 | 34.0 | 16.0 | 16.0 | 22.0 | 34.0 | 16.0 | 34.0 | 16.0 | 16.0 | 22.0 | 34.0 |
SPESIFIKASI DESAIN | ||||||||||||||||||
GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | GB150 | |
BAHAN UTAMA | ||||||||||||||||||
SS | SS | SS | SS | SS | SS | SS | SS | SS | SS | SS | SS | SS/CS | SS/CS | SS/CS | SS/CS | SS/CS | SS/CS | |
KAPASITAS PENYIMPANAN | ||||||||||||||||||
Nitrogen | ||||||||||||||||||
SCF | 22,697 | TIDAK TERSEDIA | TIDAK TERSEDIA | 22,697 | 45,395 | TIDAK TERSEDIA | TIDAK TERSEDIA | 45,395 | 68,094 | TIDAK TERSEDIA | TIDAK TERSEDIA | 68,094 | 45,395 | 45,395 | 68,094 | TIDAK TERSEDIA | TIDAK TERSEDIA | 68,094 |
Nm3 | 643 | TIDAK TERSEDIA | TIDAK TERSEDIA | 643 | 1,286 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,286 | 1,929 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,929 | 1,286 | 1,286 | 1,929 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,929 |
Oksigen | ||||||||||||||||||
SCF | 28,240 | TIDAK TERSEDIA | TIDAK TERSEDIA | 28,240 | 40,480 | TIDAK TERSEDIA | TIDAK TERSEDIA | 40,480 | 84,720 | TIDAK TERSEDIA | TIDAK TERSEDIA | 84,720 | 40,480 | 40,480 | 84,720 | TIDAK TERSEDIA | TIDAK TERSEDIA | 84,720 |
Nm3 | 800 | TIDAK TERSEDIA | TIDAK TERSEDIA | 800 | 1600 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1600 | 2400 | TIDAK TERSEDIA | TIDAK TERSEDIA | 2400 | 1600 | 1600 | 2400 | TIDAK TERSEDIA | TIDAK TERSEDIA | 2400 |
Argon | ||||||||||||||||||
SCF | 27,534 | TIDAK TERSEDIA | TIDAK TERSEDIA | 27,534 | 55,068 | TIDAK TERSEDIA | TIDAK TERSEDIA | 55,068 | 82,602 | TIDAK TERSEDIA | TIDAK TERSEDIA | 82,602 | 55,068 | 55,068 | 82,602 | TIDAK TERSEDIA | TIDAK TERSEDIA | 82,602 |
Nm3 | 780 | TIDAK TERSEDIA | TIDAK TERSEDIA | 780 | 1560 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1560 | 2340 | TIDAK TERSEDIA | TIDAK TERSEDIA | 2340 | 1560 | 1560 | 2340 | TIDAK TERSEDIA | TIDAK TERSEDIA | 2340 |
NG | ||||||||||||||||||
SCF | TIDAK TERSEDIA | 21,180 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 42,360 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 63,540 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 63,540 | TIDAK TERSEDIA | TIDAK TERSEDIA |
Nm3 | TIDAK TERSEDIA | 600 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,200 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,800 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,800 | TIDAK TERSEDIA | TIDAK TERSEDIA |
CO2 | ||||||||||||||||||
SCF | TIDAK TERSEDIA | TIDAK TERSEDIA | 19,415 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 38,830 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 58,245 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 58,245 | TIDAK TERSEDIA |
Nm3 | TIDAK TERSEDIA | TIDAK TERSEDIA | 550 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,100 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,650 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,650 | TIDAK TERSEDIA |
PERFORMA TERMAL (NER %/HARI) | ||||||||||||||||||
N2 | 0.80% | 0.80% | 0.80% | 0.80% | 0.70% | 0.70% | 0.70% | 0.70% | 0.60% | 0.60% | 0.60% | 0.60% | 1.00% | 1.00% | 0.90% | 0.90% | 0.90% | 0.90% |
O2 | 0.53% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.53% | 0.47% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.47% | 0.40% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.40% | 0.67% | 0.67% | 0.60% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.60% |
Ar | 0.56% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.56% | 0.49% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.49% | 0.42% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.42% | 0.70% | 0.70% | 0.63% | TIDAK TERSEDIA | TIDAK TERSEDIA | 0.63% |
TINGKAT PENGIRIMAN GAS (LIN/LO2/LAR) | ||||||||||||||||||
SCF/H | 882.5 | TIDAK TERSEDIA | TIDAK TERSEDIA | 882.5 | 1,412 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,412 | 1,412 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,412 | 1,412 | 1,412 | 1,412 | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,412 |
Nm3/H | 25 | TIDAK TERSEDIA | TIDAK TERSEDIA | 25 | 40 | TIDAK TERSEDIA | TIDAK TERSEDIA | 40 | 40 | TIDAK TERSEDIA | TIDAK TERSEDIA | 40 | 40 | 40 | 40 | TIDAK TERSEDIA | TIDAK TERSEDIA | 40 |
TINGKAT PENGIRIMAN GAS (LNG) | ||||||||||||||||||
SCF/H | TIDAK TERSEDIA | 776.6 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,341 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,341 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 1,341 | TIDAK TERSEDIA | TIDAK TERSEDIA |
Nm3/H | TIDAK TERSEDIA | 22 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 38 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 38 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 38 | TIDAK TERSEDIA | TIDAK TERSEDIA |
LAJU PEMBERIAN GAS (CO2) | ||||||||||||||||||
SCF/H | TIDAK TERSEDIA | TIDAK TERSEDIA | 282.4 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 423.6 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 423.6 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 423.6 | TIDAK TERSEDIA |
Nm3/H | TIDAK TERSEDIA | TIDAK TERSEDIA | 8 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 12 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 12 | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | TIDAK TERSEDIA | 12 | TIDAK TERSEDIA |
DIMENSI | ||||||||||||||||||
Diameter | ||||||||||||||||||
in | 55 | 55 | 55 | 55 | 67 | 67 | 67 | 67 | 75 | 75 | 75 | 75 | 67 | 67 | 91 | 91 | 91 | 91 |
mm | 1,400 | 1,400 | 1,400 | 1,400 | 1,700 | 1,700 | 1,700 | 1,700 | 1,900 | 1,900 | 1,900 | 1,900 | 1,700 | 1,700 | 2,300 | 2,300 | 2,300 | 2,300 |
Tinggi | ||||||||||||||||||
in | 96.8 | 99.9 | 96.6 | 96.8 | 119.5 | 124.3 | 119.5 | 119.5 | 122 | 128 | 122 | 122 | 150.7 | 150.7 | 155.8 | 161.8 | 155.8 | 155.8 |
mm | 2,458.40 | 2,538.40 | 2,453 | 2,458.40 | 3,035 | 3,155 | 3,035 | 3,035 | 3,104 | 3,254 | 3,104 | 3,104 | 3,826 | 3,826 | 3,956 | 4,108 | 3,956 | 3,956 |
Bobot Tara | ||||||||||||||||||
lbs | 2,433 | 2,492 | 2,442 | 2,642 | 3,454 | 3,454 | 3,454 | 4,092 | 4,396 | 4,508 | 4,816 | 5,232 | 6,494 | 7,139 | 7,825 | 8,039 | 8,292 | 8,703 |
kg | 1,106 | 1,132.50 | 1,110 | 1,201 | 1,570 | 1,570 | 1,570 | 1,860 | 1,998 | 2,049 | 2,189 | 2,378 | 2,952 | 3,245 | 3,557 | 3,654 | 3,769 | 3,956 |
Q1: Jika Anda adalah perusahaan pabrik atau perusahaan perdagangan?
kami adalah produsen dengan lebih dari 20 tahun.Pemasok dengan izin usaha terverifikasi