Tipe | NB48-10KDZ | NB96-10KDZ | NB120-10KDZ | NB240-10KDZ | |
Input DC | Input tegangan tetapan | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Arus tetapan input | 231 A | 116 A | 93 A | 46 A | |
Rentang voltase DC input | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
Input AC | Memungkinkan kisaran tegangan input | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | |||
Arus tetapan input | 91A / 104A / 45.5 A / 42A | ||||
Waktu transfer pintasan | ≤40 ms(dapat disesuaikan ≤4ms Version) | ||||
Output AC | Daya tetapan output | 10KW | |||
Tegangan dan frekuensi tetapan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Arus tetapan output | 91A / 104A / 45.5 A /42A | ||||
Akurasi tegangan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | ||||
Akurasi frekuensi output | 50Hz / 60Hz ± 0.05% | ||||
Distorsi bentuk gelombang (THD, Waveform distorsi). | ≤3% (Beban linear) | ||||
Waktu respons dinamis (Muat 0←→100%) |
2 md | ||||
Faktor daya (PF, Power Factor) | 1 | ||||
Kapasitas beban berlebih | 120 %,5 menit;200 %,3 detik | ||||
Faktor diam (CF) | 3:1 | ||||
Efisiensi Inverter | 94% | ||||
Lingkungan Kerja | Kekuatan dielektrik | 1500 VAC,1 menit | |||
Noise (1m) | ≤50dB | ||||
Suhu sekitar | -20 | ||||
Kelembapan | 0 90%, tanpa kondensasi | ||||
Ketinggian | Daya tetapan <6000m lebih tinggi daripada 2000m harus dikurangi | ||||
Fungsi Produksi | Perlindungan input mundur, input dengan tegangan rendah, perlindungan kelebihan beban output, perlindungan hubung-singkat output, perlindungan panas | ||||
Dilengkapi dengan transformer isolasi | Ya | ||||
Gelombang Sinus murni | Ya | ||||
Pengisi Daya AC | Tersedia, opsional | ||||
Pengisi Daya Baterai Solar | Tersedia, opsional | ||||
Kontak kering | Tersedia. Opsional | ||||
Ukuran | 550*480*1200 mm | ||||
Berat | 130kg |
Tipe | NB48-15KDZ | NB96-15KDZ | NB120-15KDZ | NB240-15KDZ | |
Input DC | Input tegangan tetapan | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Arus tetapan input | 347 A | 174 A | 139 A | 69 A | |
Rentang voltase DC input | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
Input AC (AC Bypass) |
Memungkinkan kisaran tegangan input | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | |||
Arus tetapan input | 136A / 125A / 68A / 62,5A | ||||
Waktu transfer pintasan | ≤100 ms(dapat disesuaikan ≤4ms Version) | ||||
Output AC | Daya tetapan output | 15KW | |||
Tegangan dan frekuensi tetapan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Arus tetapan output | 136A / 125A / 68A / 62,5A | ||||
Akurasi tegangan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | ||||
Akurasi frekuensi output | 50Hz / 60Hz ± 0.05% | ||||
Distorsi bentuk gelombang (THD, Waveform distorsi). | ≤3% (Beban linear) | ||||
Waktu respons dinamis (Muat 0←→100%) |
2 md | ||||
Faktor daya (PF, Power Factor) | 1 | ||||
Kapasitas beban berlebih | 120 %,5 menit;200 %,3 detik | ||||
Faktor diam (CF) | 3:1 | ||||
Efisiensi Inverter | 94% | ||||
Lingkungan Kerja | Kekuatan dielektrik | 1500 VAC,1 menit | |||
Noise (1m) | ≤50dB | ||||
Suhu sekitar | -20 | ||||
Kelembapan | 0 90%, tanpa kondensasi | ||||
Ketinggian | <6000m (Lebih tinggi dari 2000m daya tetapan harus dikurangi) |
||||
Fungsi Produksi | Perlindungan input mundur, input dengan tegangan rendah, perlindungan kelebihan beban output, perlindungan hubung-singkat output, perlindungan panas | ||||
Dilengkapi dengan transformer isolasi | Ya | ||||
Gelombang Sinus murni | Ya | ||||
Pengisi Daya AC | Tersedia, opsional | ||||
Pengisi Daya Baterai Solar | Tersedia, opsional | ||||
Kontak kering | Tersedia. Opsional | ||||
Ukuran | 550*480*1200 mm | ||||
Berat | 200 kg |
Tipe | NB48-20KDZ | NB96-20KDZ | NB120-20KDZ | NB240-20KDZ | |
Input DC | Input tegangan tetapan | 48 VDC | 96 VDC | 120 VDC | 240 VDC |
Arus tetapan input | 463 A | 231 A | 185 A | 93 A | |
Rentang voltase DC input | 40-62 VDC | 80-124 VDC | 100-155 VDC | 200-310 VDC | |
Input AC (AC Bypass) |
Memungkinkan kisaran tegangan input | 110 VAC /120 VAC /220 VAC /240 VAC ± 15% VAC | |||
Arus tetapan input | 182A / 167A / 91 A / 83A | ||||
Waktu transfer pintasan | ≤100 ms(dapat disesuaikan ≤4ms Version) | ||||
Output AC | Daya tetapan output | 20KW | |||
Tegangan dan frekuensi tetapan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC , 50 Hz / 60 Hz | ||||
Arus tetapan output | 182A / 167A / 91 A / 83A | ||||
Akurasi tegangan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC±1% | ||||
Akurasi frekuensi output | 50Hz / 60Hz ± 0.05% | ||||
Distorsi bentuk gelombang (THD, Waveform distorsi). | ≤3% (Beban linear) | ||||
Waktu respons dinamis (Muat 0←→100%) |
2 md | ||||
Faktor daya (PF, Power Factor) | 1 | ||||
Kapasitas beban berlebih | 120 %,5 menit;200 %,3 detik | ||||
Faktor diam (CF) | 3:1 | ||||
Efisiensi Inverter | 90% | ||||
Lingkungan Kerja | Kekuatan dielektrik | 1500 VAC,1 menit | |||
Noise (1m) | ≤50dB | ||||
Suhu sekitar | -20 | ||||
Kelembapan | 0 90%, tanpa kondensasi | ||||
Ketinggian | Daya tetapan <6000m lebih tinggi daripada 2000m harus dikurangi | ||||
Fungsi Produksi | Perlindungan input mundur, input dengan tegangan rendah, perlindungan kelebihan beban output, perlindungan hubung-singkat output, perlindungan panas | ||||
Dilengkapi dengan transformer isolasi | Ya | ||||
Gelombang Sinus murni | Ya | ||||
Pengisi Daya AC | Tersedia, opsional | ||||
Pengisi Daya Baterai Solar | Tersedia, opsional | ||||
Kontak kering | Tersedia. Opsional | ||||
Ukuran | 610*950*1300mm | ||||
Berat | 210kg |
30KW pada parameter teknis inverter fase tunggal
Tipe | NB120-30KDZ | NB240-30KDZ | NB380-30KDZ | |
Input DC | Input tegangan tetapan | 120 VDC | 240 VDC | 380 VDC |
Arus tetapan input | 278 A | 139 A | 88 A | |
Rentang voltase DC input | 100-155 VDC | 200-310 VDC | 320-496VDC | |
Input AC (AC Bypass) |
Memungkinkan kisaran tegangan input | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% VAC | ||
Arus tetapan input | 272A / 250A / 136 A / /125MM | |||
Waktu transfer pintasan | ≤100 ms(dapat disesuaikan ≤4ms Version) | |||
Output AC | Daya tetapan output | 30KW | ||
Tegangan dan frekuensi tetapan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | |||
Arus tetapan output | 272A / 250A / 136 A / /125MM | |||
Akurasi tegangan output | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 1% | |||
Akurasi frekuensi output | 50Hz / 60Hz ±0.05% | |||
Distorsi bentuk gelombang (THD, Waveform distorsi). | ≤3% (Beban linear) | |||
Waktu respons dinamis (Muat 0←→100%) |
2 md | |||
Faktor daya (PF, Power Factor) | 1 | |||
Kapasitas beban berlebih | 120 %,5 menit;200 %,3 detik | |||
Faktor diam (CF) | 3:1 | |||
Efisiensi Inverter | 94% | |||
Lingkungan Kerja | Kekuatan dielektrik | 1500 VAC,1 menit | ||
Noise (1m) | ≤50dB | |||
Suhu sekitar | -20 | |||
Kelembapan | 0 90%, tanpa kondensasi | |||
Ketinggian | Daya tetapan <6000m lebih tinggi daripada 2000m harus dikurangi | |||
Fungsi Produksi | Perlindungan input mundur, input dengan tegangan rendah, perlindungan kelebihan beban output, perlindungan hubung-singkat output, perlindungan panas | |||
Dilengkapi dengan transformer isolasi | Ya | |||
Gelombang Sinus murni | Ya | |||
Pengisi Daya AC | Tersedia, opsional | |||
Pengisi Daya Baterai Solar | Tersedia, opsional | |||
Kontak kering | Tersedia. Opsional | |||
Ukuran (mm) | 800*600*2260mm | |||
Berat(kg) | 360 kg |