Nature of Source Flow: | Active Inverter |
---|---|
Certification: | CCC, ISO9001, RoHS, CE, SAA |
Output Power: | 1-3kw |
Grid Type: | Grid Inverter |
Output Type: | Single |
Circuit Topologies: | Full-Bridge Type |
Pemasok dengan izin usaha terverifikasi
Data Teknis | Ahasta-1P1K1G | Ahasta-1P2K1G | Ahasta-1P3K1G |
Deskripsi | Cukup tinggi Austickeneffefisien 1KW 2KW kisi inverter tali diikat Dengan pengontrol MPPT | ||
Sumber energi | PV tersambung kisi | ||
Sisi Input | |||
Daya Input Maks.DC(kW) | 1.3 | 2.6 | 3.9 |
Tegangan Input Maks.DC(V) | 500 | 500 | 500 |
Tegangan Input DC Start(V) On-up | 80 | 120 | 120 |
Rentang Pengoperasian MPPT(V) | 70-500 | 100-500 | 100-500 |
Arus Input Maks.DC(A) | 13 | 13 | 13 |
Jumlah MPPT/String per MPPT | 1/1 | 1/1 | 1/1 |
Sisi Output | |||
Daya Output Tetapan(kW) | 1 | 2 | 3 |
Daya Maks.Aktif(kW) | 1.1 | 2.2 | 3.3 |
Tegangan Kisi AC Tetapan (V) | 230 | 230 | 230 |
Rentang Tegangan Grid AC(V) | 160-300 | 160-300 | 160-300 |
Frekuensi Grid Tetapan (Hz) | 50/60(Opsional) | 50/60(Opsional) | 50/60(Opsional) |
Fase Operasi | Fase tunggal | Fase tunggal | Fase tunggal |
Arus Output Kisi AC Tetapan (A) | 4.3 | 8.7 | 13.1 |
Arus Output Maks.AC(A) | 4.7 | 9.6 | 14 |
Faktor Daya Output | 0.8 mengarah ke 0.8 gurut | ||
Grid Current THD | <3% | <3% | <3% |
DC injeksi Arus(mA) | <0.5% | <0.5% | <0.5% |
Rentang Frekuensi Kisi | 47-52 atau 57-62(Opsional) | 47-52 atau 57-62(Opsional) | 47-52 atau 57-62(Opsional) |
Efisiensi | |||
Efisiensi Maks. | 0.973 | 0.973 | 0.975 |
Efisiensi Euro | 0.971 | 0.971 | 0.973 |
Efisiensi MPPT | >99% | >99% | >99% |
Perlindungan | |||
Perlindungan Anti-islanding | Terintegrasi | ||
Perlindungan polaritas Balik DC | Terintegrasi | ||
Perlindungan lonjakan Listrik DC | Terintegrasi(Tipe II) | ||
Perlindungan lonjakan Listrik AC | Terintegrasi(Tipe II) | ||
Perlindungan hubung-singkat AC | Terintegrasi | ||
Output AC Perlindungan Arus Berlebih | Terintegrasi | ||
Perlindungan tegangan berlebih output | Terintegrasi | ||
Pemantauan Kisi AC | Terintegrasi | ||
Monitoring kerusakan arde | Terintegrasi | ||
Perlindungan resistan Isolasi | Terintegrasi | ||
Residual Current Monitoring Unit (Unit Pemantauan Arus residu) | Terintegrasi | ||
Perlindungan Temperatur | Terintegrasi | ||
Sakelar DC Terpadu | Opsional | ||
Data Umum | |||
Ukuran (mm) | 330W*310H*115D | ||
Berat(kg) | 6 kg | ||
Topologi | Tanpa TransformemerLanguage | ||
Konsumsi internal | <1W(malam) | ||
Suhu Pengoperasian | -25-60 | ||
Proteksi masuknya benda asing (ingress) | IP65 | ||
Emisi bising(Tipikal) | <30dB | ||
Konsep pendingin | Pendinginan yang cerdas | ||
Ketinggian Pengoperasian Maks. tanpa penurunan Daya | 2000 m | ||
Didesain seumur hidup | >20 tahun | ||
Kelembapan sekitar Pengoperasian | 0-100% | ||
Fitur | |||
Koneksi DC | DAPAT berubah menjadi mc-4 | ||
Koneksi AC | Sumbat tetapan IP65 | ||
Tampilan | LCD1602 | ||
Antarmuka | RS485/RS232 | ||
Sertifikasi&Standar | |||
Pengaturan Grid (Kisi) | IEC61727 /62116 /60068 /61683 | IEC61727 /62116 /60068 /61683 | IEC61727 /62116 /60068 /61683 /INMETRO (ABNTNBR 16149 /16150) |
Peraturan Keselamatan | IEC/EN62109-1/2 | ||
Peraturan EMC | / |
Pemasok dengan izin usaha terverifikasi