Nature of Source Flow: | Active Inverter |
---|---|
Certification: | CCC, ISO9001, CE, SAA |
Output Power: | 80kw |
Grid Type: | Grid Inverter |
Output Type: | Triple |
Circuit Topologies: | Full-Bridge Type |
Pemasok dengan izin usaha terverifikasi
Data Teknis | Aosta-3P60K1G | Ahasta-3P70K1G | Auta-3P75K1G | Auta-3P80K1G |
Deskripsi | 80 kw biaya Inverter String yang efektif untuk Grid yang tersambung ke Sistem PV | |||
Sumber energi |
PV tersambung kisi
|
|||
Sisi Input | ||||
Daya Input Maks.DC(kW)
|
78 | 91 | 97.5 | 100 |
Tegangan Input Maks.DC(V)
|
1000
|
1000
|
1000
|
1000
|
Tegangan Input DC Start(V) On-up
|
250
|
250
|
250
|
250
|
Rentang Pengoperasian MPPT(V)
|
200-850
|
200-850
|
200-850
|
200-850
|
Arus Input Maks.DC(A)
|
39+39+39+39
|
56+56+56+56
|
56+56+56+56
|
56+56+56+56
|
Jumlah MPPT/String per MPPT
|
4/3
|
4/4
|
4/4 | 4/4 |
Sisi Output
|
||||
Daya Output Tetapan(kW)
|
60 | 70 | 75 | 80 |
Daya Maks.Aktif(kW)
|
66 | 77 | 82.5 | 88 |
Tegangan Kisi AC Tetapan (V)
|
380/400
|
380/400
|
380/400
|
380/400
|
Rentang Tegangan Grid AC(V)
|
277-460
|
277-460
|
277-460
|
277-460
|
Frekuensi Grid Tetapan (Hz)
|
50/60(Opsional)
|
50/60(Opsional)
|
50/60(Opsional)
|
50/60(Opsional)
|
Fase Operasi
|
Tiga fase
|
Tiga fase
|
Tiga fase
|
Tiga fase
|
Arus Output Kisi AC Tetapan (A)
|
87.8 | 101.5 | 108.7 | 115.9 |
Arus Output Maks.AC(A)
|
95.7 | 111.6 | 119.6 | 127.5 |
Faktor Daya Output
|
0.8 mengarah ke 0.8 gurut
|
|||
Grid Current THD
|
<3%
|
<3%
|
<3%
|
<3%
|
DC injeksi Arus(mA)
|
<0.5%
|
<0.5%
|
<0.5%
|
<0.5%
|
Rentang Frekuensi Kisi
|
47-52/57-62(Opsional)
|
|||
Efisiensi
|
||||
Efisiensi Maks.
|
98.9%
|
98.9%
|
98.9%
|
98.9%
|
Efisiensi Euro
|
98.3%
|
98.3%
|
98.3%
|
98.3%
|
Efisiensi MPPT
|
>99%
|
>99%
|
>99%
|
>99%
|
Perlindungan
|
||||
Perlindungan Anti-islanding
|
Terintegrasi
|
|||
Perlindungan polaritas Balik DC
|
Terintegrasi
|
|||
Perlindungan lonjakan Listrik DC
|
Terintegrasi(Tipe II)
|
|||
Perlindungan lonjakan Listrik AC
|
Terintegrasi(Tipe II)
|
|||
Perlindungan hubung-singkat AC
|
Terintegrasi
|
|||
Output AC Perlindungan Arus Berlebih
|
Terintegrasi
|
|||
Perlindungan tegangan berlebih output
|
Terintegrasi
|
|||
Pemantauan Kisi AC
|
Terintegrasi
|
|||
Monitoring kerusakan arde
|
Terintegrasi
|
|||
Perlindungan resistan Isolasi
|
Terintegrasi
|
|||
Residual Current Monitoring Unit (Unit Pemantauan Arus residu)
|
Terintegrasi
|
|||
Perlindungan Temperatur
|
Terintegrasi
|
|||
Sakelar DC Terpadu
|
Opsional
|
|||
Data Umum
|
||||
Ukuran (mm)
|
700W*575H*297D
|
|||
Berat(kg)
|
60 | |||
Topologi
|
Tanpa TransformemerLanguage
|
|||
Konsumsi internal
|
<1W(malam)
|
|||
Suhu Pengoperasian
|
-25-60
|
|||
Proteksi masuknya benda asing (ingress)
|
IP65
|
|||
Emisi bising(Tipikal)
|
<30dB
|
|||
Konsep pendingin
|
Pendinginan yang cerdas
|
|||
Ketinggian Pengoperasian Maks. tanpa penurunan Daya
|
2000 m
|
|||
Didesain seumur hidup
|
>20 tahun
|
|||
Kelembapan sekitar Pengoperasian
|
0-100%
|
|||
Fitur
|
||||
Koneksi DC
|
DAPAT berubah menjadi mc-4
|
|||
Koneksi AC
|
Sumbat tetapan IP65
|
|||
Tampilan
|
LCD1602
|
|||
Antarmuka
|
RS485/RS232
|
|||
Sertifikasi&Standar
|
||||
Pengaturan Grid (Kisi)
|
IEC61727/62116/60068/61683/50549
|
|||
Peraturan Keselamatan
|
IEC/EN62109-1/2
|
|||
Peraturan EMC
|
IEC/EN61000-6-1/61000-6-3/61000-6-4
|
Pemasok dengan izin usaha terverifikasi